  • Modular automatic backup power transfer switch with protection functions | for generators | for uninterrupted power supply | 4 inputs | 2P | 100A | 230V

    Code: ES-JMRD-PN4
    Price 119.21 € VAT incl.
    ( 98.52 € VAT excl. )
    Buy more, pay less
    10+ pcs.  – 101.31 € for pcs. -15%
    Want another price? Suggest yours!

    4-source Automatic Transfer Switch (ATS) – a smart 230V AC, 100A, 2P single-phase power source transfer switch capable of automatically selecting one of up to 4 independent power inputs. Suitable for systems using the mains supply, generator, inverter or energy storage system. The device features automatic and manual operating modes, adjustable source priority, overvoltage, undervoltage, overcurrent and overheating protection, adjustable delays, a display showing input voltages and load current, and COM/NO/NC dry contacts for integration with PLC, BMS or generator controllers. 

  • 4-Source Automatic Transfer Switch ATS | 2P | 100A | 230V AC | Voltage and Overcurrent Protection | Feedback Contacts

    Smart 4-input Automatic Transfer Switch (ATS) designed for single-phase 230V AC systems using several independent power sources. The device can automatically select one of up to 4 power inputs, monitor their voltage, load current and fault conditions, and transfer the load to another suitable source.

    The transfer switch features a 2-pole design, meaning that both the phase and neutral conductors are switched during transfer. Integrated protection against overvoltage, undervoltage, overcurrent and overheating, manual and automatic operating modes, adjustable delay times, selectable source priority, timer function, audible fault alarm and potential-free COM/NO/NC feedback contacts are provided.

    Up to 4 independent power sources

    The device can be used with different single-phase power sources, such as the utility grid, generator, solar inverter or energy storage system. If the priority source fails or moves outside the permitted parameters, the load is automatically transferred to another available source according to the configured priority sequence.

    4 inputs
    Power source selection
    2P
    Phase and neutral switching
    100A
    Rated current
    230V AC
    50Hz

    Operating principle

    The main function is to automatically maintain power to the load when one of the electrical power sources fails or its parameters become unsuitable. The device continuously monitors the connected inputs and selects an appropriate power source according to the configured priority.

    Situation Operation
    L1 operates normally The load is supplied from L1 if it is configured as the priority source.
    L1 fails or moves outside the configured limits Another suitable source, for example L2, is selected automatically.
    L2 becomes unsuitable The system can transfer to L3 and subsequently to L4.
    Priority source is restored After the configured delay time, the system can automatically return to the priority input.
    Manual mode The power source can be selected manually.

    Power source priority selection

    Configurable source priority

    A typical transfer sequence can be L1 → L2 → L3 → L4. For example, L1 can be the main utility grid, L2 a generator, L3 a solar inverter and L4 an additional backup source. The priority sequence can be changed according to the requirements of the specific system.

    2-pole switching – phase and neutral

    Each input is 2P, meaning that not only the phase conductor but also the neutral conductor is switched. This allows the selected source to be fully isolated from the other inputs and is particularly relevant in systems using generators, inverters or other independent power sources.

    Important information regarding the neutral conductor

    The neutral and protective earth arrangement of a generator, inverter or other backup source must be designed according to the specific electrical installation. 2P switching itself does not replace the requirement to correctly design the N and PE conductor system.

    Integrated protection functions

    Protection Function
    Overvoltage protection Disconnects or prevents the use of a source when its voltage exceeds the configured limit.
    Undervoltage protection Protects the load from operation at excessively low supply voltage.
    Overcurrent protection Monitors the load current and responds when the configured limit is exceeded.
    Overtemperature protection Monitors the device temperature and indicates an abnormal condition.
    This is not a surge protective device (SPD)

    The integrated overvoltage function monitors the mains voltage level. It does not replace a separate SPD designed to limit lightning-induced or other transient surge voltages.

    Display and indication

    The integrated display allows monitoring of the voltage of all four inputs and the output load current. Additional indicators provide information about faults, overcurrent, temperature alarm, timer operation, power status and audible alarm status.

    Indicator / control Function
    Main switch Main power / control button.
    Menu Settings menu.
    Timer Timer ON / OFF function.
    Fault Fault indicator.
    Temp Temperature alarm indicator.
    Over current Overcurrent indication.
    Mute Audible alarm mute.
    Power Power indication.

    Automatic and manual transfer

    The device supports automatic and manual source selection. In automatic mode, the power inputs are continuously monitored, while in manual mode a specific source can be selected by the operator.

    Adjustable protection and delay parameters

    Overvoltage setting range 120–300V
    Undervoltage setting range 80–210V
    Overcurrent setting range 1–100A
    Overcurrent delay 0.1–30s
    Power-on delay 1–999s
    Transfer delay 1–999s

    Potential-free feedback contacts

    COM / NO / NC dry contacts

    The feedback output is potential-free. It does not itself provide 12V, 24V or 230V. The contacts operate as a conventional relay changeover contact: COM, NO and NC. An external PLC, controller, alarm system or other device provides the voltage used for the signal circuit.

    What information can be transmitted via the dry contacts?

    Signal group Typical statuses
    Power supply status Main supply normal, backup supply normal, mains failure / undervoltage.
    ATS status Selected power source, transfer status, transfer fault.
    Alarm ATS fault, abnormal voltage, transfer timeout or another control signal.
    The exact feedback signal depends on the specific output wiring diagram

    COM/NO/NC contacts alone do not indicate which specific status is assigned to them. Before connecting the contacts to a PLC, generator controller or alarm system, the contact diagram for the specific device must be followed.

    Dedicated generator control contacts

    The device can be used in systems where a generator is used as a backup power source. A dedicated generator control signal can be used together with the generator controller for automatic starting or stopping.

    Typical generator control sequence

    Main utility supply fails → ATS detects the fault → dry contact changes state → generator controller receives a start command → once the generator reaches acceptable electrical parameters, the ATS transfers the load.

    ATS + PLC

    In industrial and automation systems, the feedback dry contacts can be connected to PLC digital inputs. The PLC can record the time of a mains failure, transfer time and selected power source and use this information to control other equipment.

    • Power failure logging
    • Transfer time logging
    • Interlocking of motors, fans or pumps
    • Alarm activation
    • Remote ATS status monitoring

    ATS + inverter / energy storage system

    The transfer switch can be integrated into systems with grid-connected inverters or energy storage systems when it is necessary to determine which power source is currently supplying the load. A dry contact can be used as a logic signal for other control equipment.

    The ATS is not a power source synchronisation device

    This type of transfer switch is designed to select one power source. It is not intended to synchronise the phases of different AC sources or operate them in parallel. The generator and inverter must have their own appropriate control and protection systems.

    Remote monitoring / BMS / EMS

    The feedback contacts can be connected to a data acquisition module, PLC or building management system. This allows ATS status signals to be transmitted to a BMS, EMS or remote monitoring platform.

    Technical specifications

    Product type Automatic Transfer Switch (ATS) with protection functions
    Power system Single-phase
    Number of inputs 4
    Number of poles 2P per source
    Rated voltage 230V AC
    Frequency 50Hz
    Rated current 100A
    Overcurrent setting 1–100A
    Overcurrent delay 0.1–30s
    Power-on delay 1–999s
    Transfer delay 1–999s
    Protection functions Overvoltage, undervoltage, overcurrent, overheating
    Control modes Automatic / manual
    Timer function Yes, scheduled ON / OFF
    Source priority Configurable
    Display 4 input voltages + output current
    Audible alarm Yes
    Feedback contacts Potential-free dry contacts COM / NO / NC
    Generator control Dedicated contacts / logic control provided
    Mechanical service life 1x106 cycles
    Electrical service life 1x105 cycles
    Operating temperature -20°C ~ +50°C
    Dimensions 210x118x73mm
    Mounting 35mm DIN rail or surface / wall mounting

    Advantages

    • Up to 4 power sources in a single transfer device.
    • 100A rated current suitable for higher-power single-phase systems.
    • 2P switching disconnects both phase and neutral.
    • Automatic source selection reduces the need for manual switching.
    • Configurable priority allows the main and backup power sources to be selected.
    • Manual mode allows the operator to select the required input.
    • Overvoltage, undervoltage, overcurrent and overheating protection.
    • Adjustable delays allow the transfer logic to be adapted to the specific system.
    • Display of all 4 input voltages and output current allows local monitoring of system status.
    • Potential-free COM/NO/NC contacts allow integration with PLC, BMS, EMS, alarm systems or generator controllers.
    • Generator control capability is suitable for automatic backup power systems.
    • Audible alarm provides fault notification.
    • 35mm DIN rail mounting allows integration into an electrical distribution panel.

    Limitations

    • Single-phase system: designed for 230V AC single-phase sources, not for a standard 3x400V three-phase ATS system.
    • Up to 100A: the load and conductor cross-sections must be selected according to the actual current and installation conditions.
    • Dry contacts do not provide voltage: the PLC or other controller must provide its own signal circuit supply.
    • This is not an SPD: voltage monitoring does not replace a surge protective device.
    • Not designed for parallel source operation: the load must be supplied by one selected source at a time.

    Suitable for

    • Main utility supply and generator transfer systems
    • Utility grid + solar inverter + generator systems
    • Energy storage systems
    • Industrial automation
    • PLC-controlled electrical systems
    • Server rooms and technical rooms
    • Pumping stations
    • Agricultural facilities
    • Building Management Systems (BMS)
    • Remote power source status monitoring systems

    Not suitable for

    • Standard three-phase 400V ATS systems
    • Loads above 100A
    • Power source phase synchronisation
    • Parallel connection of multiple AC sources
    • Use as a replacement for a surge protective device
    • Use as a replacement for a protective circuit breaker or fuse where such protection is required by the installation

    Practical application example

    A facility uses the main utility grid, a backup generator and a solar inverter. L1 is selected as the main source. If L1 fails or its voltage moves outside the configured limits, the ATS selects another suitable source after the configured delay time. At the same time, a dry contact can transmit a signal to the generator controller or PLC. When the priority L1 supply is restored, the system automatically transfers the load back to the main source after the configured delay.

    Frequently Asked Questions (FAQ)

    How many power sources can be connected?

    Up to four single-phase 230V AC power sources.

    Can a generator be connected?

    Yes. The device is designed for systems using the utility grid, a generator and other backup power sources.

    Can a solar inverter be used?

    Yes, provided that the inverter AC output electrical parameters comply with the requirements of the 230V AC system and the installation is designed so that the sources cannot be improperly connected in parallel.

    Is the neutral conductor switched?

    Yes. A 2P design is used, so both the phase and neutral conductors are switched.

    What is the rated current?

    The rated current is 100A.

    Can the overcurrent threshold be adjusted?

    Yes. The specified overcurrent setting range is 1A to 100A.

    Can the main power source be selected?

    Yes. The device provides a power source priority selection function.

    Can the sources be switched manually?

    Yes. Both automatic and manual transfer modes are supported.

    What is a dry contact?

    It is a potential-free COM/NO/NC relay contact. It does not itself provide 12V, 24V or 230V and is used as a logic signal for another controller.

    Can the dry contact be connected to a PLC?

    Yes. This is one of the most typical applications. The PLC input circuit supply must be provided by the PLC or another external power source.

    Can the ATS automatically start a generator?

    It can be used together with a generator controller via a dedicated dry contact. The contact itself does not power the generator – it only transmits a control status.

    Is the current shown on the display?

    Yes. The display shows the output load current and the voltages of all four inputs.

    Is there an audible alarm?

    Yes. An audible alarm can be activated in the event of an electrical fault and can be muted.

    How is the device mounted?

    35mm DIN rail mounting is supported, as well as surface / wall mounting.

    What are the dimensions?

    210x118x73mm.

    Important electrical safety and system design information

    A 100A ATS must be installed and connected according to the design requirements of the specific electrical installation. Cable cross-section, short-circuit protection, circuit breaker or fuse characteristics, neutral and PE arrangement, generator and inverter control logic and overall system selectivity must be taken into account. Dry contacts must only be connected according to the specific contact wiring diagram. The ATS is not designed for parallel connection of different AC sources or for phase synchronisation between them.

    4-source Automatic Transfer Switch ATS – 230V AC, 100A, 2P single-phase power source transfer switch with automatic and manual control, configurable source priority, overvoltage, undervoltage, overcurrent and overheating protection, adjustable delays, display of 4 input voltages and output current, audible alarm and potential-free COM/NO/NC feedback contacts. Suitable for utility grid, generator, inverter, energy storage, PLC, BMS and other backup power supply systems.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.