Modular automatic backup power transfer switch with protection functions | for generators | for uninterrupted power supply | 4 inputs | 2P | 100A | 230V
Code: ES-JMRD-PN4Price 119.21 € VAT incl.( 98.52 € VAT excl. )Buy more, pay less10+ pcs. – 101.31 € for pcs. -15%Want another price? Suggest yours!4-source Automatic Transfer Switch (ATS) – a smart 230V AC, 100A, 2P single-phase power source transfer switch capable of automatically selecting one of up to 4 independent power inputs. Suitable for systems using the mains supply, generator, inverter or energy storage system. The device features automatic and manual operating modes, adjustable source priority, overvoltage, undervoltage, overcurrent and overheating protection, adjustable delays, a display showing input voltages and load current, and COM/NO/NC dry contacts for integration with PLC, BMS or generator controllers.
-
4-Source Automatic Transfer Switch ATS | 2P | 100A | 230V AC | Voltage and Overcurrent Protection | Feedback Contacts
Smart 4-input Automatic Transfer Switch (ATS) designed for single-phase 230V AC systems using several independent power sources. The device can automatically select one of up to 4 power inputs, monitor their voltage, load current and fault conditions, and transfer the load to another suitable source.
The transfer switch features a 2-pole design, meaning that both the phase and neutral conductors are switched during transfer. Integrated protection against overvoltage, undervoltage, overcurrent and overheating, manual and automatic operating modes, adjustable delay times, selectable source priority, timer function, audible fault alarm and potential-free COM/NO/NC feedback contacts are provided.
Up to 4 independent power sourcesThe device can be used with different single-phase power sources, such as the utility grid, generator, solar inverter or energy storage system. If the priority source fails or moves outside the permitted parameters, the load is automatically transferred to another available source according to the configured priority sequence.
4 inputsPower source selection2PPhase and neutral switching100ARated current230V AC50HzOperating principle
The main function is to automatically maintain power to the load when one of the electrical power sources fails or its parameters become unsuitable. The device continuously monitors the connected inputs and selects an appropriate power source according to the configured priority.
Situation Operation L1 operates normally The load is supplied from L1 if it is configured as the priority source. L1 fails or moves outside the configured limits Another suitable source, for example L2, is selected automatically. L2 becomes unsuitable The system can transfer to L3 and subsequently to L4. Priority source is restored After the configured delay time, the system can automatically return to the priority input. Manual mode The power source can be selected manually. Power source priority selection
Configurable source priorityA typical transfer sequence can be L1 → L2 → L3 → L4. For example, L1 can be the main utility grid, L2 a generator, L3 a solar inverter and L4 an additional backup source. The priority sequence can be changed according to the requirements of the specific system.
2-pole switching – phase and neutral
Each input is 2P, meaning that not only the phase conductor but also the neutral conductor is switched. This allows the selected source to be fully isolated from the other inputs and is particularly relevant in systems using generators, inverters or other independent power sources.
Important information regarding the neutral conductorThe neutral and protective earth arrangement of a generator, inverter or other backup source must be designed according to the specific electrical installation. 2P switching itself does not replace the requirement to correctly design the N and PE conductor system.
Integrated protection functions
Protection Function Overvoltage protection Disconnects or prevents the use of a source when its voltage exceeds the configured limit. Undervoltage protection Protects the load from operation at excessively low supply voltage. Overcurrent protection Monitors the load current and responds when the configured limit is exceeded. Overtemperature protection Monitors the device temperature and indicates an abnormal condition. This is not a surge protective device (SPD)The integrated overvoltage function monitors the mains voltage level. It does not replace a separate SPD designed to limit lightning-induced or other transient surge voltages.
Display and indication
The integrated display allows monitoring of the voltage of all four inputs and the output load current. Additional indicators provide information about faults, overcurrent, temperature alarm, timer operation, power status and audible alarm status.
Indicator / control Function Main switch Main power / control button. Menu Settings menu. Timer Timer ON / OFF function. Fault Fault indicator. Temp Temperature alarm indicator. Over current Overcurrent indication. Mute Audible alarm mute. Power Power indication. Automatic and manual transfer
The device supports automatic and manual source selection. In automatic mode, the power inputs are continuously monitored, while in manual mode a specific source can be selected by the operator.
Adjustable protection and delay parameters
Overvoltage setting range 120–300V Undervoltage setting range 80–210V Overcurrent setting range 1–100A Overcurrent delay 0.1–30s Power-on delay 1–999s Transfer delay 1–999s Potential-free feedback contacts
COM / NO / NC dry contactsThe feedback output is potential-free. It does not itself provide 12V, 24V or 230V. The contacts operate as a conventional relay changeover contact: COM, NO and NC. An external PLC, controller, alarm system or other device provides the voltage used for the signal circuit.
What information can be transmitted via the dry contacts?
Signal group Typical statuses Power supply status Main supply normal, backup supply normal, mains failure / undervoltage. ATS status Selected power source, transfer status, transfer fault. Alarm ATS fault, abnormal voltage, transfer timeout or another control signal. The exact feedback signal depends on the specific output wiring diagramCOM/NO/NC contacts alone do not indicate which specific status is assigned to them. Before connecting the contacts to a PLC, generator controller or alarm system, the contact diagram for the specific device must be followed.
Dedicated generator control contacts
The device can be used in systems where a generator is used as a backup power source. A dedicated generator control signal can be used together with the generator controller for automatic starting or stopping.
Typical generator control sequenceMain utility supply fails → ATS detects the fault → dry contact changes state → generator controller receives a start command → once the generator reaches acceptable electrical parameters, the ATS transfers the load.
ATS + PLC
In industrial and automation systems, the feedback dry contacts can be connected to PLC digital inputs. The PLC can record the time of a mains failure, transfer time and selected power source and use this information to control other equipment.
- Power failure logging
- Transfer time logging
- Interlocking of motors, fans or pumps
- Alarm activation
- Remote ATS status monitoring
ATS + inverter / energy storage system
The transfer switch can be integrated into systems with grid-connected inverters or energy storage systems when it is necessary to determine which power source is currently supplying the load. A dry contact can be used as a logic signal for other control equipment.
The ATS is not a power source synchronisation deviceThis type of transfer switch is designed to select one power source. It is not intended to synchronise the phases of different AC sources or operate them in parallel. The generator and inverter must have their own appropriate control and protection systems.
Remote monitoring / BMS / EMS
The feedback contacts can be connected to a data acquisition module, PLC or building management system. This allows ATS status signals to be transmitted to a BMS, EMS or remote monitoring platform.
Technical specifications
Product type Automatic Transfer Switch (ATS) with protection functions Power system Single-phase Number of inputs 4 Number of poles 2P per source Rated voltage 230V AC Frequency 50Hz Rated current 100A Overcurrent setting 1–100A Overcurrent delay 0.1–30s Power-on delay 1–999s Transfer delay 1–999s Protection functions Overvoltage, undervoltage, overcurrent, overheating Control modes Automatic / manual Timer function Yes, scheduled ON / OFF Source priority Configurable Display 4 input voltages + output current Audible alarm Yes Feedback contacts Potential-free dry contacts COM / NO / NC Generator control Dedicated contacts / logic control provided Mechanical service life 1x106 cycles Electrical service life 1x105 cycles Operating temperature -20°C ~ +50°C Dimensions 210x118x73mm Mounting 35mm DIN rail or surface / wall mounting Advantages
- Up to 4 power sources in a single transfer device.
- 100A rated current suitable for higher-power single-phase systems.
- 2P switching disconnects both phase and neutral.
- Automatic source selection reduces the need for manual switching.
- Configurable priority allows the main and backup power sources to be selected.
- Manual mode allows the operator to select the required input.
- Overvoltage, undervoltage, overcurrent and overheating protection.
- Adjustable delays allow the transfer logic to be adapted to the specific system.
- Display of all 4 input voltages and output current allows local monitoring of system status.
- Potential-free COM/NO/NC contacts allow integration with PLC, BMS, EMS, alarm systems or generator controllers.
- Generator control capability is suitable for automatic backup power systems.
- Audible alarm provides fault notification.
- 35mm DIN rail mounting allows integration into an electrical distribution panel.
Limitations
- Single-phase system: designed for 230V AC single-phase sources, not for a standard 3x400V three-phase ATS system.
- Up to 100A: the load and conductor cross-sections must be selected according to the actual current and installation conditions.
- Dry contacts do not provide voltage: the PLC or other controller must provide its own signal circuit supply.
- This is not an SPD: voltage monitoring does not replace a surge protective device.
- Not designed for parallel source operation: the load must be supplied by one selected source at a time.
Suitable for
- Main utility supply and generator transfer systems
- Utility grid + solar inverter + generator systems
- Energy storage systems
- Industrial automation
- PLC-controlled electrical systems
- Server rooms and technical rooms
- Pumping stations
- Agricultural facilities
- Building Management Systems (BMS)
- Remote power source status monitoring systems
Not suitable for
- Standard three-phase 400V ATS systems
- Loads above 100A
- Power source phase synchronisation
- Parallel connection of multiple AC sources
- Use as a replacement for a surge protective device
- Use as a replacement for a protective circuit breaker or fuse where such protection is required by the installation
Practical application example
A facility uses the main utility grid, a backup generator and a solar inverter. L1 is selected as the main source. If L1 fails or its voltage moves outside the configured limits, the ATS selects another suitable source after the configured delay time. At the same time, a dry contact can transmit a signal to the generator controller or PLC. When the priority L1 supply is restored, the system automatically transfers the load back to the main source after the configured delay.
Frequently Asked Questions (FAQ)
How many power sources can be connected?Up to four single-phase 230V AC power sources.
Can a generator be connected?Yes. The device is designed for systems using the utility grid, a generator and other backup power sources.
Can a solar inverter be used?Yes, provided that the inverter AC output electrical parameters comply with the requirements of the 230V AC system and the installation is designed so that the sources cannot be improperly connected in parallel.
Is the neutral conductor switched?Yes. A 2P design is used, so both the phase and neutral conductors are switched.
What is the rated current?The rated current is 100A.
Can the overcurrent threshold be adjusted?Yes. The specified overcurrent setting range is 1A to 100A.
Can the main power source be selected?Yes. The device provides a power source priority selection function.
Can the sources be switched manually?Yes. Both automatic and manual transfer modes are supported.
What is a dry contact?It is a potential-free COM/NO/NC relay contact. It does not itself provide 12V, 24V or 230V and is used as a logic signal for another controller.
Can the dry contact be connected to a PLC?Yes. This is one of the most typical applications. The PLC input circuit supply must be provided by the PLC or another external power source.
Can the ATS automatically start a generator?It can be used together with a generator controller via a dedicated dry contact. The contact itself does not power the generator – it only transmits a control status.
Is the current shown on the display?Yes. The display shows the output load current and the voltages of all four inputs.
Is there an audible alarm?Yes. An audible alarm can be activated in the event of an electrical fault and can be muted.
How is the device mounted?35mm DIN rail mounting is supported, as well as surface / wall mounting.
What are the dimensions?210x118x73mm.
Important electrical safety and system design informationA 100A ATS must be installed and connected according to the design requirements of the specific electrical installation. Cable cross-section, short-circuit protection, circuit breaker or fuse characteristics, neutral and PE arrangement, generator and inverter control logic and overall system selectivity must be taken into account. Dry contacts must only be connected according to the specific contact wiring diagram. The ATS is not designed for parallel connection of different AC sources or for phase synchronisation between them.
4-source Automatic Transfer Switch ATS – 230V AC, 100A, 2P single-phase power source transfer switch with automatic and manual control, configurable source priority, overvoltage, undervoltage, overcurrent and overheating protection, adjustable delays, display of 4 input voltages and output current, audible alarm and potential-free COM/NO/NC feedback contacts. Suitable for utility grid, generator, inverter, energy storage, PLC, BMS and other backup power supply systems.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Network plug | RJ45 connector (8P8C) | for UTP CAT 6e cable | unshielded | through-plug | transparentCode: WT117Price 0.20 € VAT incl.( 0.17 € VAT excl. )Price 0.98 € VAT incl.( 0.81 € VAT excl. )U-FTP Cable | 6A CAT | 4x2x23 AWG | shielded | copper | UV resistant | outdoor use | blackCode: KIF6AOUTS500Price 0.73 € VAT incl.( 0.60 € VAT excl. )