    Multifunction voltage and current monitoring relay 100A – a DIN rail-mounted protection device for single-phase electrical circuits. The relay monitors voltage, load current, leakage current and temperature, and automatically disconnects the load when the set limits are exceeded. Overcurrent protection is adjustable from 1–100A. The device features a digital display, programmable delays, fault history and automatic reconnection once normal mains parameters are restored. 

  • Multifunction Voltage and Current Monitoring Relay | 100A | Automatic Reclosing | Leakage Current and Temperature Protection

    Multifunction voltage and current monitoring relay with automatic reclosing – a microcontroller-controlled DIN rail protection device designed to monitor the parameters of a single-phase electrical circuit and disconnect the load when the preset limits are exceeded. The device provides overvoltage, undervoltage, overcurrent up to 100A, leakage current and temperature protection, a digital display and automatic power restoration.

    The digital display shows the operating voltage and load current. Protection thresholds, trip delays, recovery delay and other parameters can be programmed using the front-panel buttons. The overcurrent protection can be adjusted within the 1–100A range.

    100A version with adjustable overcurrent protection

    The overcurrent protection threshold can be adjusted from 1A to 100A. The default setting is 80A. When the set current is exceeded, the load is disconnected after the selected 0.1–30s delay.

    100A
    Max. overcurrent setting
    80–300V AC
    Operating voltage range
    Class 0.5
    Measurement accuracy
    1–999s
    Recovery delay

    Operating principle

    Condition Device response
    Parameters normal The output contact is closed and the load is powered.
    Overvoltage The load is disconnected after the preset trip delay.
    Undervoltage The load is disconnected when the voltage falls below the preset threshold.
    Overcurrent When the threshold set within the 1–100A range is exceeded, the circuit is disconnected after the selected delay.
    Leakage current Protection is activated when the preset 10–100mA threshold is exceeded.
    Overtemperature The load is disconnected when the preset temperature threshold is reached.
    Fault cleared Power is automatically restored after the preset recovery delay.

    Protection functions

    Protection Setting range Function
    Overvoltage protection 120-300V / OFF Disconnects the load when the preset voltage limit is exceeded.
    Undervoltage protection 80-210V / OFF Protects the load against excessively low mains voltage.
    Overcurrent protection 1-100A / OFF Disconnects the circuit when the preset load current is exceeded.
    Leakage current protection 10-100mA / OFF Responds when the preset residual current threshold is exceeded.
    Temperature protection 50-120°C / OFF Disconnects the load when the preset temperature threshold is reached.

    100A overcurrent monitoring

    Adjustable from 1A to 100A

    The overcurrent protection threshold can be set in 1A increments. The default value is 80A. When the actual current exceeds the preset threshold, protection trips after a programmable 0.1–30s delay.

    Automatic reclosing

    After a temporary mains fault, the device can automatically restore power to the load. The recovery delay can be adjusted from 1 to 999 seconds. This prevents the load from being switched on immediately after the mains voltage returns.

    Repeated overcurrent protection

    It is possible to set the number of overcurrent trips permitted before automatic reclosing is blocked. The permitted number is 1–20 trips, or the function can be disabled. When the selected number of trips is exceeded, the circuit remains disconnected and a manual reset is required.

    Leakage current protection

    The leakage current threshold can be set from 10 to 100mA. The protection response time is up to approximately 100ms. A dedicated leakage protection test button is provided on the front panel.

    Leakage protection is not automatically a substitute for an RCD / RCBO

    Where a separate RCD or RCBO is required by the electrical design or applicable regulations, the integrated leakage current function should not be regarded as a substitute for such a protective device unless its suitability and compliance for that purpose have been separately confirmed.

    Temperature protection

    The temperature protection threshold can be adjusted from 50°C to 120°C. The default value is 85°C. After the temperature protection trips, approximately 10°C hysteresis is applied to prevent the device from repeatedly switching at the exact preset threshold.

    Voltage protection and hysteresis

    5V hysteresis is used for overvoltage and undervoltage protection. This means that the output is not restored at exactly the same voltage threshold at which the protection was triggered. This operating principle reduces the risk of frequent contact switching when the mains voltage fluctuates around the preset threshold.

    Digital voltage and current display

    The integrated digital display allows monitoring of the operating voltage and load current. Measurement accuracy is Class 0.5. Voltage and current readings can be corrected within a ±9.9% range in 0.1% increments.

    Indication Meaning
    >U< Overvoltage / undervoltage indication
    >I Overcurrent indication
    IΔn Leakage current indication
    Power Power indication

    Fault history

    The device records protection trip causes and allows them to be reviewed through the menu. Up to 999 fault records can be stored.

    Code Fault
    PD Power failure
    UU Undervoltage
    OU Overvoltage
    OC Overcurrent
    LE Leakage current protection
    HT Overtemperature

    Password-protected settings

    The parameter menu can be protected with a password from 000–999. When password protection is enabled, unauthorised users can be prevented from changing the configured protection thresholds.

    Programmable parameters

    Menu Parameter Range Default value
    P-1 Power-on delay 1-999s 5s
    P-2 Recovery delay 1-999s 30s
    P-3 Overvoltage protection 120-300V / OFF 270V
    P-4 Undervoltage protection 80-210V / OFF 170V
    P-5 Voltage protection trip delay 0.1-30s 0.5s
    P-6 Voltage correction ±9.9% 0%
    P-7 Overcurrent protection 1-100A / OFF 80A
    P-8 Overcurrent trip delay 0.1-30s 1s
    P-9 Current correction ±9.9% 0%
    P-10 Repeated overcurrent trip count 1-20 / OFF OFF
    P-11 Leakage current protection 10-100mA / OFF 30mA
    P-12 Temperature protection 50-120°C / OFF 85°C
    P-13 Fault history Up to 999 records –
    P-14 Password 000-999 118

    Technical specifications

    Product type Multifunction voltage and current monitoring relay with automatic reclosing
    Rated current / overcurrent range Up to 100A, adjustable 1-100A
    Default overcurrent threshold 80A
    Rated supply voltage AC 110V / 230V
    Operating voltage range AC 80-300V
    Frequency 50/60Hz
    Measurement accuracy Class 0.5
    Overvoltage protection 120-300V / OFF
    Overvoltage hysteresis 5V
    Undervoltage protection 80-210V / OFF
    Undervoltage hysteresis 5V
    Overcurrent protection 1-100A / OFF
    Overcurrent protection delay 0.1-30s
    Leakage current protection 10-100mA / OFF
    Leakage protection response time Up to 100ms
    Temperature protection 50-120°C / OFF
    Temperature hysteresis 10°C
    Power-on delay 1-999s
    Recovery delay 1-999s
    Voltage / current correction ±9.9%
    Output contact 1NO
    Rated insulation voltage 450V
    Impulse overvoltage category Class III
    Electrical service life 1x105 cycles
    Mechanical service life 1x106 cycles
    Protection rating IP20
    Pollution degree 3
    Operating altitude <2000m
    Operating temperature -5°C ~ +40°C
    Storage temperature -10°C ~ +55°C
    Dimensions 50x111x70mm
    Mounting DIN rail

    Advantages

    • Overcurrent monitoring up to 100A with adjustment in 1A increments.
    • Automatic reclosing when normal mains parameters are restored.
    • Overvoltage and undervoltage protection with programmable thresholds.
    • Leakage current monitoring within the 10–100mA range.
    • Temperature protection adjustable up to 120°C.
    • Digital voltage and current display.
    • Adjustable protection delays allow operation to be adapted to different loads.
    • Fault history for up to 999 records.
    • Password protection for parameter settings.
    • DIN rail mounting for convenient integration into an electrical distribution board.

    Limitations

    • IP20: designed for installation inside an enclosed electrical distribution board.
    • Maximum current 100A: the protection threshold and conductor cross-section must correspond to the actual circuit load.
    • Operating temperature up to +40°C: suitable conditions must be maintained inside the electrical enclosure.
    • Leakage current protection should not be considered a substitute for an RCD / RCBO without separate confirmation of suitability.
    • Class III impulse overvoltage protection does not replace a complete coordinated building SPD system.

    Suitable for

    • Single-phase electrical distribution boards
    • Residential and commercial premises
    • Equipment sensitive to mains voltage fluctuations
    • Loads where current must be limited to a preset value between 1–100A
    • Systems requiring automatic power restoration after a temporary fault
    • Protection of pumps, heating, ventilation and other single-phase electrical circuits, provided their parameters are within the device ratings

    Not suitable for

    • Loads exceeding 100A
    • Exposed outdoor installation
    • Environments with corrosive gases or direct exposure to rain
    • Use as the sole short-circuit protection device
    • Use as a substitute for a circuit breaker, fuse or project-required RCD / RCBO

    Practical application example

    In an electrical distribution board, the relay is used to monitor a single-phase load of up to 100A. For example, the overcurrent threshold can be set to 63A. If the load current exceeds 63A for longer than the selected delay time, the relay disconnects the circuit. Once the cause of the fault has been eliminated and the parameters return to normal, power can be automatically restored after the preset recovery delay.

    Frequently Asked Questions (FAQ)

    What is the maximum overcurrent protection threshold?

    100A. The threshold can be adjusted from 1A to 100A.

    What is the default current protection setting?

    The default overcurrent setting is 80A.

    Can the threshold be set to 63A, for example?

    Yes. The overcurrent threshold is adjustable in 1A increments within the 1–100A range.

    Does the relay automatically restore power?

    Yes. Once normal parameters are restored, power can be reconnected after an adjustable delay of 1–999s.

    Can the overvoltage threshold be adjusted?

    Yes. Overvoltage protection is adjustable within the 120–300V range or can be switched off.

    Can the undervoltage threshold be adjusted?

    Yes. The protection threshold can be adjusted within the 80–210V range or the function can be switched off.

    Does it provide leakage current monitoring?

    Yes. The threshold can be set from 10 to 100mA.

    Does it provide overtemperature protection?

    Yes. The temperature protection threshold can be adjusted from 50°C to 120°C.

    Does the display show current and voltage?

    Yes. The digital display shows the operating voltage and load current.

    Can previous faults be reviewed?

    Yes. Up to 999 records can be stored in the fault history.

    Can the settings be password protected?

    Yes. The password can be set within the 000–999 range.

    Is a circuit breaker required upstream of the relay?

    Yes. The input circuit must be protected by a correctly selected circuit breaker.

    Important installation and electrical safety information

    The device must be installed by a qualified electrical professional. A correctly selected circuit breaker must be installed on the input side. Before installation or maintenance work, all power sources must be disconnected and the absence of voltage at the terminals must be verified. Do not touch the terminals while the power supply is switched on. Before energising the device, check all wiring and terminal connections. The device is designed for installation inside a protected electrical enclosure and must not be directly exposed to rain, intense sunlight or corrosive gases.

    Multifunction Voltage and Current Monitoring Relay 100A – a DIN rail protection device with adjustable 1–100A overcurrent monitoring, overvoltage and undervoltage protection, leakage current and temperature monitoring, digital voltage and current display, fault history and automatic power restoration when acceptable mains parameters are restored.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Price 30.25 € VAT incl.
    ( 25.00 € VAT excl. )
    Price 32.50 € VAT incl.
    ( 26.86 € VAT excl. )
  • privacy policy

    Information