Modular | digital voltage and current monitoring | protection | phase sequence imbalance relay | 3-phase | 1-100A | 380V | DIN rail
Code: ESTVPS3-100An advanced three-phase voltage and current protection relay designed to ensure maximum safety of electrical systems in both industrial and residential environments. The device monitors the network status in real time and automatically disconnects the load in case of dangerous conditions: overvoltage, undervoltage, current overload, phase imbalance, or incorrect phase sequence.
This is an ideal choice for installers, engineers, and even advanced users seeking reliable triple protection.
-
Modular digital voltage and current monitoring relay – 3-phase, 1–100A, 380V, DIN, phase sequence and imbalance protection
Modular three-phase voltage and current protection relay – an advanced DIN rail device designed to monitor the electrical network condition and automatically disconnect the load when dangerous parameters occur: over-voltage, under-voltage, over-current, phase loss, phase imbalance or incorrect phase sequence.
Main idea:
This relay is designed for protection and monitoring of three-phase electrical systems when it is necessary to monitor each phase voltage in real time, control current limits up to 100A and automatically disconnect the load in case of a dangerous network fault.System
3 phaseCurrent
1–100AVoltage
230V with N / 380V without NMounting
DIN railOperating principle
The relay continuously monitors the three-phase network voltage, current, phase sequence, phase loss and phase imbalance. When the voltage or current exceeds the set limits, the relay automatically disconnects the load and helps protect electrical equipment from faults.
After normal network conditions are restored, the device can automatically resume operation after the set recovery delay time. The display shows each phase voltage, making it easier to assess the electrical network condition in real time.
Versions according to the network:
100A with N wire – designed for 3 x 230V + N system, the display shows each phase voltage of 230V.
100A without N wire – designed for 3-phase 380V system, L1 / L2 / L3 display 380V voltage.Technical specifications
Product type Modular digital voltage and current monitoring / protection relay Network type 3 phase Maximum current 100A Current adjustment 1–100A Voltage with N wire 3 x 230V + N, the display shows each phase voltage of 230V Voltage without N wire 3-phase 380V, L1 / L2 / L3 display 380V voltage Mounting DIN rail Display Digital display, shows each phase voltage Protections Over-voltage, under-voltage, over-current, phase imbalance, phase sequence and phase loss protection 230V with N wire operating range
Power-on delay time 1–500 s, factory setting 10 s, step 1 s Over-voltage protection value 230–300V, factory setting 270V, step 1V Over-voltage recovery value 225–295V, factory setting 265V, step 1V Over-voltage recovery delay time 1–500 s, factory setting 30 s, step 1 s Over-voltage protection action time 0.1–30 s, factory setting 1.0 s, step 0.1 s Under-voltage protection value 140–210V, factory setting 170V, step 1V Under-voltage recovery value 145–215V, factory setting 175V, step 1V Under-voltage recovery delay time 1–500 s, factory setting 30 s, step 1 s Under-voltage protection action time 0.1–30 s, factory setting 1.0 s, step 0.1 s Three-phase voltage error correction -9.5% to +9.5%, factory setting 0 Three-phase voltage imbalance value 20–99V, factory setting 20V, step 1V Three-phase voltage imbalance recovery value 15–94V, factory setting 15V, step 1V Phase sequence protection OFF / ON, factory setting ON Over-current protection value 1–100A, factory setting 30A, step 1A Over-current recovery delay time 1–500 s, factory setting 30 s, step 1 s Over-current protection action time 0.1–30 s, factory setting 1.0 s, step 0.1 s Three-phase current error correction -9.5% to +9.5%, factory setting 0 Number of continuous over-current protection actions 0–20, factory setting OFF Phase loss protection ON 380V without N wire operating range
Power-on delay time 1–500 s, factory setting 10 s, step 1 s Over-voltage protection value 395–520V, factory setting 460V, step 1V Over-voltage recovery value 390–515V, factory setting 455V, step 1V Over-voltage recovery delay time 1–500 s, factory setting 30 s, step 1 s Over-voltage protection action time 0.1–30 s, factory setting 1.0 s, step 0.1 s Under-voltage protection value 240–365V, factory setting 300V, step 1V Under-voltage recovery value 245–370V, factory setting 305V, step 1V Under-voltage recovery delay time 1–500 s, factory setting 30 s, step 1 s Under-voltage protection action time 0.1–30 s, factory setting 1.0 s, step 0.1 s Three-phase voltage error correction -9.5% to +9.5%, factory setting 0 Three-phase voltage imbalance value 20–99V, factory setting 40V, step 1V Three-phase voltage imbalance recovery value 15–94V, factory setting 35V, step 1V Three-phase voltage imbalance protection switch OFF / ON, factory setting OFF Over-current protection value 1–100A-OFF, factory setting 30A, step 1A Over-current recovery delay time 1–500 s, factory setting 30 s, step 1 s Over-current protection action time 0.1–30 s, factory setting 1.0 s, step 0.1 s Three-phase current error correction -9.5% to +9.5%, factory setting 0 Number of continuous over-current protection actions 0–20-OFF, factory setting OFF Phase loss protection ON Main functions
- Adjustable over-voltage protection – disconnects the load when the voltage exceeds the set limit.
- Adjustable under-voltage protection – protects equipment from operating at too low network voltage.
- Adjustable over-current protection up to 100A – allows the current limit to be set according to the load.
- Phase asymmetry protection – disconnects the load when the phase voltage difference becomes too large.
- Phase sequence protection – helps protect motors and other equipment from incorrect phase sequence.
- Phase loss protection – disconnects the load when one of the phases is missing.
- Automatic recovery – the relay can restore operation after the set delay when parameters return to normal.
- Real-time phase voltage display – L1, L2 and L3 status can be monitored on the display.
Where is it used?
- Electrical panels – for three-phase input protection against over-voltage, under-voltage and overloads.
- Industrial equipment – for protection of motors, pumps, compressors, fans and other loads.
- Household three-phase systems – for homes or homesteads with three-phase electrical input.
- Commercial facilities – for shops, workshops, warehouses and technical rooms.
- Generator and UPS systems – for voltage stability monitoring and safe disconnection.
- Solar power systems – for network parameter monitoring and protective disconnection.
Three-phase voltage, current, phase sequence and imbalance protection relay up to 100A
The modular digital voltage and current monitoring relay 3F 1–100A 380V DIN is a professional solution for protecting three-phase electrical systems against over-voltage, under-voltage, over-current, phase loss, phase sequence error and phase imbalance.
With adjustable limits, automatic recovery, real-time voltage display, DIN mounting and a wider current range up to 100A, this relay is suitable for electrical panels, industrial equipment, motors, pumps, generators, UPS, solar power systems and other three-phase systems where reliable and flexible protection is required.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Digital Voltage Control | Protection Relay | 63A | 230VCode: ESAVP-63Price 32.50 € VAT incl.( 26.86 € VAT excl. )Price 30.25 € VAT incl.( 25.00 € VAT excl. )Terminal clamp | electrical wire connector | universal | 2x0.2-4mm² | for all wire types | WAGO | 221-412 | 4050821808435Code: WAGO 221-412Price 0.30 € VAT incl.( 0.25 € VAT excl. )





















