    Code: ESTVPS3-63

    An advanced three-phase voltage and current protection relay designed to ensure maximum safety of electrical systems in both industrial and residential environments. The device monitors the network status in real time and automatically disconnects the load in case of dangerous conditions: overvoltage, undervoltage, current overload, phase imbalance, or incorrect phase sequence.

    This is an ideal choice for installers, engineers, and even advanced users seeking reliable triple protection. 

  • Modular digital voltage and current monitoring relay – 3-phase, 1-63A, 380V, DIN, phase sequence and imbalance protection

    Modular three-phase voltage and current protection relay – an advanced device designed to monitor the electrical network condition and automatically disconnect the load when dangerous parameters occur: over-voltage, under-voltage, over-current, phase loss, phase imbalance or incorrect phase sequence.

    Main idea:
    This relay is designed for protection and monitoring of three-phase electrical systems, when it is necessary to monitor each phase voltage in real time, control current limits and automatically disconnect the load in case of a dangerous network fault.
    System
    3 phases
    Current
    1-63A
    Voltage
    380V / 3-phase
    Mounting
    DIN rail

    Operating principle

    The relay continuously monitors the three-phase network voltage, current, phase sequence, phase loss and phase imbalance. When the voltage or current exceeds the set limits, the relay automatically disconnects the load and helps protect electrical equipment from faults.

    After normal network conditions are restored, the device can automatically resume operation after the set recovery delay time. The display shows each phase voltage, making it easier for the user to assess the electrical network condition in real time.

    Why is this type of protection relay needed?
    In three-phase systems, danger can be caused not only by over-voltage or under-voltage, but also by phase loss, incorrect phase sequence, phase imbalance or excessive load current. This relay combines several protection functions in one device and allows them to be adjusted according to specific network conditions.

    Technical specifications

    Product type Modular digital voltage and current monitoring / protection relay
    Network type 3 phases
    Maximum current 63A
    Current adjustment 1-63A / 3-63A, depending on the setting mode
    Voltage with N wire 3 x 230V + N, the display shows each phase voltage of 230V
    Voltage without N wire 3-phase 380V, L1 / L2 / L3 display 380V voltage
    Mounting DIN rail
    Display Digital display, shows each phase voltage
    Protections Over-voltage, under-voltage, over-current, phase imbalance, phase sequence and phase loss protection

    230V with N wire operating range

    Power-on delay time 1-500 s, factory setting 10 s, step 1 s
    Over-voltage protection value 230-300V, factory setting 270V, step 1V
    Over-voltage recovery value 225-295V, factory setting 265V, step 1V
    Over-voltage recovery delay time 1-500 s, factory setting 30 s, step 1 s
    Over-voltage protection action time 0.1-30 s, factory setting 1.0 s, step 0.1 s
    Under-voltage protection value 140-210V, factory setting 170V, step 1V
    Under-voltage recovery value 145-215V, factory setting 175V, step 1V
    Under-voltage recovery delay time 1-500 s, factory setting 30 s, step 1 s
    Under-voltage protection action time 0.1-30 s, factory setting 1.0 s, step 0.1 s
    Three-phase voltage error correction -9.5% to +9.5%, factory setting 0
    Three-phase voltage imbalance value 20-99V, factory setting 20V, step 1V
    Three-phase voltage imbalance recovery value 15-94V, factory setting 15V, step 1V
    Phase sequence protection OFF / ON, factory setting ON
    Over-current protection value 1–63A, factory setting 30A, step 1A
    Over-current recovery delay time 1-500 s, factory setting 30 s, step 1 s
    Over-current protection action time 0.1-30 s, factory setting 1.0 s, step 0.1 s
    Three-phase current error correction -9.5% to +9.5%, factory setting 0
    Number of continuous over-current protection actions 0-20, factory setting OFF
    Phase loss protection ON

    380V without N wire operating range

    Power-on delay time 1-500 s, factory setting 10 s, step 1 s
    Over-voltage protection value 395-520V, factory setting 460V, step 1V
    Over-voltage recovery value 390-515V, factory setting 455V, step 1V
    Over-voltage recovery delay time 1-500 s, factory setting 30 s, step 1 s
    Over-voltage protection action time 0.1-30 s, factory setting 1.0 s, step 0.1 s
    Under-voltage protection value 240-365V, factory setting 300V, step 1V
    Under-voltage recovery value 245-370V, factory setting 305V, step 1V
    Under-voltage recovery delay time 1-500 s, factory setting 30 s, step 1 s
    Under-voltage protection action time 0.1-30 s, factory setting 1.0 s, step 0.1 s
    Three-phase voltage error correction -9.5% to +9.5%, factory setting 0
    Three-phase voltage imbalance value 20-99V, factory setting 40V, step 1V
    Three-phase voltage imbalance recovery value 15-94V, factory setting 35V, step 1V
    Three-phase voltage imbalance protection switch OFF / ON, factory setting OFF
    Over-current protection value 1-63A-OFF, factory setting 30A, step 1A
    Over-current recovery delay time 1-500 s, factory setting 30 s, step 1 s
    Over-current protection action time 0.1-30 s, factory setting 1.0 s, step 0.1 s
    Three-phase current error correction -9.5% to +9.5%, factory setting 0
    Number of continuous over-current protection actions 0-20-OFF, factory setting OFF
    Phase loss protection ON

    Main functions

    • Adjustable over-voltage protection – disconnects the load when the voltage exceeds the set limit.
    • Adjustable under-voltage protection – protects equipment from operating at too low network voltage.
    • Adjustable over-current protection – allows the current limit to be set according to the load.
    • Phase asymmetry protection – disconnects the load when the phase voltage difference becomes too large.
    • Phase sequence protection – helps protect motors and other equipment from incorrect phase sequence.
    • Phase loss protection – disconnects the load when one of the phases is missing.
    • Automatic recovery – the relay can restore operation after the set delay when parameters return to normal.
    • Real-time phase voltage display – L1, L2 and L3 status can be monitored on the display.

    Where is it used?

    • Electrical panels – for three-phase input protection against over-voltage, under-voltage and overloads.
    • Industrial equipment – for protection of motors, pumps, compressors, fans and other loads.
    • Household three-phase systems – for homes or homesteads with three-phase electrical input.
    • Commercial facilities – for shops, workshops, warehouses and technical rooms.
    • Generator and UPS systems – for voltage stability monitoring and safe disconnection.
    • Solar power systems – for network parameter monitoring and protective disconnection.

    Use according to need

    For household users: suitable for protecting a home three-phase input when you want to protect household appliances, heating equipment, pumps or other three-phase devices from network faults.

    For companies and industry: helps protect motors, compressors, pumps, production equipment and other sensitive devices from phase loss, over-voltage, under-voltage and overload.

    For engineers / designers: a suitable solution when the project requires adjustable three-phase protection with over-voltage, under-voltage, over-current, phase sequence and imbalance functions.

    For electricians: mounted on a DIN rail, with clear parameter settings, allowing convenient adjustment of protection limits according to the specific system.

    Practical application

    In practice, this relay is installed in an electrical panel and connected to the three-phase input or to the specific protected load. It monitors L1, L2 and L3 phase voltages, controls over-current and disconnects the load when network parameters become unsafe.

    This is especially important for motors, pumps and compressors, because incorrect phase sequence, phase loss or voltage imbalance can cause incorrect rotation direction, overheating or equipment failure.

    Pros

    • Three-phase protection in one device – voltage, current, phase sequence, imbalance and phase loss.
    • Wide adjustment range – can be adapted to the specific network and load.
    • Real-time voltage display – convenient monitoring of L1, L2 and L3 phases.
    • Automatic recovery – operation is restored after the set delay when parameters normalize.
    • Suitable for both household and industrial use.
    • DIN mounting – convenient integration into electrical panels.
    • Good protection for motors – against phase loss, incorrect sequence and voltage imbalance.

    Cons / limitations

    • Proper adjustment is required – initial settings may require the help of an electrician or specialist.
    • No Wi-Fi or Modbus – control and settings are performed locally.
    • Not suitable for all systems without selection – it is necessary to check whether a version with N wire or without N wire is required.
    • The current limit must be selected correctly – an incorrect current limit may cause unnecessary disconnections or insufficient protection.
    • Does not replace all panel protections – circuit breakers, RCD/RCBO and other protection according to the project are required.

    Safety and installation notes

    The relay must be installed according to the specific electrical system diagram. Before installation, it is important to determine whether the version with N wire or without N wire is being used, and to correctly select current, voltage and recovery limits.

    • Install only with power disconnected.
    • Installation must be performed by a qualified specialist.
    • Check whether the network is 3 x 230V + N or 3-phase 380V without N.
    • Correctly set over-voltage and under-voltage limits.
    • Correctly set the current limit according to the load.
    • For motors, check the phase sequence to avoid incorrect rotation direction.
    • The relay does not replace a circuit breaker or residual current device, therefore all necessary protections must be used in the panel.

    Quick selection guide

    Choose the modular three-phase voltage and current monitoring relay when you need over-voltage, under-voltage, over-current, phase loss, phase sequence and imbalance protection in one device.

    Network
    3 phases
    Current
    1-63A
    Voltage
    230V with N / 380V without N
    Mounting
    DIN
    Suitable when you need to:
    • protect a three-phase input or load;
    • monitor each phase voltage;
    • protect motors against phase loss and incorrect sequence;
    • set the over-current protection limit;
    • automatically disconnect the load in case of a network fault.
    Check before installation:
    • whether a version with N wire or without N wire is required;
    • whether the load current does not exceed 63A;
    • whether the voltage limits match your network parameters;
    • whether phase sequence protection must be enabled;
    • whether the relay is used together with the required panel protections.
    Important reminder:
    This relay is a monitoring and protection device, but it does not replace all electrical installation protection devices. Suitable circuit breakers, residual current protection, grounding and other project-required solutions must be used in the electrical panel.

    FAQ – frequently asked questions

    What is this relay used for?
    It is used for monitoring three-phase network voltage, current, phase sequence, imbalance and phase loss, and for disconnecting the load in case of dangerous parameters.
    What is the difference between the version with N wire and without N wire?
    The version with N wire is designed for a 3 x 230V + N system and shows each phase voltage of 230V. The version without N wire is designed for a 3-phase 380V system, where L1, L2 and L3 show 380V values.
    Can the protection limits be adjusted?
    Yes, over-voltage, under-voltage, over-current, recovery and action time parameters can be adjusted.
    Does the relay protect against phase loss?
    Yes, phase loss protection is one of the main functions. If one phase is lost, the relay disconnects the load.
    Is it suitable for motors?
    Yes, the relay is especially useful for motors, pumps and compressors, as it can protect against phase loss, phase sequence error, voltage imbalance and over-current.
    Is remote control available?
    No, this relay does not have Wi-Fi or Modbus remote control. Settings are performed locally through the device control.

    Three-phase voltage, current, phase sequence and imbalance protection relay

    The modular digital voltage and current monitoring relay 3F 1-63A 380V DIN is a professional solution for protecting three-phase electrical systems against over-voltage, under-voltage, over-current, phase loss, phase sequence error and phase imbalance.

    With adjustable limits, automatic recovery, real-time voltage display, DIN mounting and wide application, this relay is suitable for electrical panels, industrial equipment, motors, pumps, generators, UPS, solar power systems and other three-phase systems where reliable and flexible protection is required.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Price 30.25 € VAT incl.
    ( 25.00 € VAT excl. )
    Price 32.50 € VAT incl.
    ( 26.86 € VAT excl. )
  • Subscribtion to new arrivals

    privacy policy

    Information