Products catalog

  • Modular single-phase electricity meter | 5(50) A | 230 V | S0 pulse output | MID | DIN | THORGEON 01005

    Code: TH-01005

    Single-phase 18 mm wide kWh meter with MID certificate and S0 pulse output, direct connection up to 50 A.

  • Modular single-phase electricity meter | 5(50) A | 230 V | S0 pulse output | MID | DIN | THORGEON 01005

    THORGEON 01005 is a one-module (18 mm) single-phase kWh meter for 230 V networks, connected directly up to 50 A. It is MID certified and has an S0 pulse output of 1000 imp/kWh.

    Key point:
    When one circuit has to be metered separately and lawfully – a rented flat, garage, summer house or single-phase charging circuit – this meter takes only one module. MID allows you to bill a tenant based on its readings, and the S0 output sends pulses to a PLC or data logger.
    Current
    5 (50) A, direct
    Voltage
    230 V, 50–60 Hz
    Accuracy
    MID, class B
    Width
    1 module (18 mm)

    Quick selection guide

    1-phase direct
    up to 50 A
    MID class B
    S0 1000 imp/kWh
    18 mm
    Suitable when you need:
    • MID-approved metering of one phase – for billing tenants or splitting costs
    • A compact meter when only one free module is left in the panel
    • A pulse signal to a PLC, BMS or data logger
    Check before use:
    • Continuous load does not exceed 50 A
    • The circuit is single-phase 230 V (L–N)
    • You do not need Modbus, wireless or separate import / export metering
    Important: The meter only measures energy – it does not protect the circuit and does not replace a circuit breaker or RCD.

    Operating principle

    The meter is mounted on a 35 mm DIN rail and connected directly into a single-phase circuit: the phase passes through the meter and the neutral is connected to its terminal. No current transformers are needed.

    The electronic measuring circuit continuously calculates active energy and accumulates the total kWh, shown on the LCD.

    Each kWh consumed is also sent as 1000 pulses via the S0 output, so readings can be counted remotely in an external system.

    Why choose THORGEON 01005?
    It combines MID-approved accuracy with minimum width: a separately metered circuit does not require rebuilding the panel or finding space for a four-module meter.

    Technical specifications

    Product type Modular single-phase electricity meter
    Manufacturer / model THORGEON 01005
    Connection Direct
    Rated voltage 230 V AC (L–N)
    Current In (Imax) 5 (50) A
    Frequency 50–60 Hz
    Accuracy class B
    MID Yes
    Tariffs 1
    Measured values Active energy (kWh)
    Pulse output S0, 1000 imp/kWh
    Communication None
    Display LCD
    Mounting / width 35 mm DIN, 1 module (18 mm)
    Dimensions (W × D × H) 18 × 63 × 116 mm
    Protection degree IP20
    Barcode 4751029890801

    Main functions

    • MID certificate – readings are valid for billing between landlord and tenant
    • Direct connection up to 50 A – no current transformers or extra equipment
    • 1-module housing – fits even into an almost full panel
    • S0 pulse output 1000 imp/kWh – readings to a PLC, BMS or data logger
    • LCD display – readings can be taken on site without tools
    • No configuration – starts counting right after installation

    Where is it used?

    • Rented flats, rooms and commercial premises
    • Garages, storage rooms and workshops
    • Summer houses and saunas
    • Single-phase EV charging circuits
    • Heat pump, boiler or air conditioner circuits
    • Sub-metering in housing associations and business centres
    • Upgrading existing panels with limited space

    Use by need

    For landlords and housing associations.
    MID-approved readings for billing tenants without disputes over accuracy.
    For installers.
    A one-module meter fits into an existing panel without rebuilding it.
    For automation integrators.
    Standard S0 signal, 1000 imp/kWh, to a counter input.

    Practical example

    If you rent out a separate flat in your house with its own single-phase circuit, install THORGEON 01005 next to that circuit's breaker. Each month you take the MID-approved reading and invoice the actual kWh consumed.

    Pros

    • MID certificate, class B
    • Only 18 mm wide
    • Direct connection up to 50 A
    • S0 pulse output 1000 imp/kWh
    • No configuration needed
    • Readings visible on the LCD

    Cons / limitations

    • Single-phase only – for a three-phase circuit choose a three-phase meter
    • No Modbus or wireless – for remote reading choose a Modbus meter
    • Single tariff
    • Import / export separation not specified – for solar PV metering choose a bidirectional meter
    • IP20 – for enclosed panels only

    Safety and installation notes

    • Installation by a qualified electrician only, with the power off.
    • Install upstream protection according to the cable cross-section; continuous current must not exceed 50 A.
    • Follow the terminal markings – swapping input and output will give incorrect readings.
    • Connect the S0 output only to a low-voltage pulse input according to the manufacturer's diagram.
    • IP20 housing – install only in an enclosed panel.

    FAQ

    Does THORGEON 01005 have MID?
    Yes, the meter is MID certified, accuracy class B.
    What is the maximum current?
    Direct connection up to 50 A (In 5 A).
    Is it suitable for a three-phase circuit?
    No, it is single-phase – a three-phase circuit needs a three-phase meter.
    Does it have Modbus?
    No, only an S0 pulse output.
    What is the pulse constant?
    1000 imp/kWh.
    How much panel space does it take?
    One module – 18 mm.

    THORGEON 01005 – single-phase MID meter 50 A, 1 module

    Single-phase 18 mm wide kWh meter with MID certificate and S0 1000 imp/kWh output – for sub-metering, rentals and cost allocation.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

  • Subscribtion to new arrivals

    privacy policy

    Information