    Three-phase voltage and phase sequence monitoring relay designed for 3×380 V AC networks with neutral. Protects electrical equipment against undervoltage, overvoltage, and incorrect phase sequence. Adjustable undervoltage threshold of 260–360 V, overvoltage threshold of 400–460 V, and trip delay of 0.1–10 s. Features a 5 A / 250 V AC changeover relay contact, automatic reset, and LED indication. Designed for 35 mm DIN rail mounting and suitable for control circuits of motors, pumps, compressors, contactors, and industrial automation systems. 

  • Three-Phase Voltage and Phase Sequence Control Relay | 3x380VAC+N | DIN

    Three-Phase Voltage and Phase Sequence Control Relay | 3x380V AC + N | Overvoltage, Undervoltage and Phase Sequence Protection

    Three-phase voltage and phase sequence control relay – is a protection device designed to protect three-phase electrical networks and sensitive equipment connected to them against improper mains voltage and incorrect phase sequence. The relay monitors phase voltage and allows the lower and upper permissible voltage limits to be set. When the mains parameters are within the permitted range and the phase sequence is correct, the output relay is activated. If overvoltage, undervoltage, or an incorrect phase sequence is detected, the control contact switches to the protective state after the configured delay.

    Three-phase network protection against voltage faults and incorrect phase sequence

    The device allows the undervoltage protection threshold to be set from 260V to 360V AC and the overvoltage protection threshold from 400V to 460V AC. The trip delay is adjustable from 0.1 to 10 seconds. The relay also monitors the phase sequence and prevents the output from being activated if the phases are connected in the wrong sequence. Once the fault is cleared, the device automatically restores operation.

    3x380V AC + N
    Monitored network
    260 – 360V
    Undervoltage threshold U<
    400 – 460V
    Overvoltage threshold U>
    0.1 – 10s
    Trip delay

    Operating principle and functions

    Function / Block Parameters / Modes Description / Purpose in the System
    Undervoltage monitoring (U<) Adjustable 260 – 360V AC If the mains voltage drops below the set threshold, the relay switches off after the configured delay and protects the connected equipment.
    Overvoltage monitoring (U>) Adjustable 400 – 460V AC If the mains voltage exceeds the set threshold, the relay output switches to the protective state after the configured delay.
    Phase sequence monitoring 3-phase sequence monitoring The relay output is not activated if the L1, L2, and L3 phase sequence is incorrect.
    Trip delay Adjustable 0.1 – 10s Helps prevent unnecessary relay operation caused by short-term mains voltage fluctuations.
    Automatic reset Auto Reset When the mains parameters return to the permitted range and the phase sequence is correct, the device automatically restores relay operation.
    LED indication LED indicators Provides visual information about the device and relay output status.

    How does the controller work?

    1. Connect the device to a three-phase 3x380V AC + N network according to the provided wiring diagram.
    2. Set the desired undervoltage protection threshold U< within the range of 260V to 360V AC.
    3. Set the desired overvoltage protection threshold U> within the range of 400V to 460V AC.
    4. Set the desired trip delay from 0.1 to 10 seconds.
    5. If the mains voltage parameters are within the set limits and the phase sequence is correct, the relay LED indicator lights up and the relay output is activated.
    6. If the voltage drops below the set U< threshold, rises above the U> threshold, or an incorrect phase sequence is detected, the relay output switches to the protective state.
    7. Once the fault is cleared and the mains parameters return to the permitted range, the relay automatically restores operation.
    Phase sequence protection

    The device additionally monitors the phase sequence of the three-phase network. If phases L1, L2, and L3 are connected in the wrong sequence, the relay output is not activated. This function is particularly important for three-phase electric motors, pumps, compressors, and other equipment whose direction of rotation depends on the phase sequence.

    Voltage protection operation

    When the monitored voltage is between the set U< and U> thresholds, the relay output remains active. If the voltage moves outside the set limits, the device begins counting the configured delay time. If the fault remains until the end of the delay, the relay switches off. Once the mains voltage returns to normal, the device automatically returns to the operating state.

    Relay contact states

    Relay state Contact state
    Normal operation / relay activated Contacts 1 – 2 are open, contacts 2 – 3 are closed.
    Protection activated / relay switched off Contacts 1 – 2 are closed, contacts 2 – 3 are open.

    Technical specifications

    Monitored voltage 3x380V AC + Neutral
    Operating frequency 50/60Hz
    Undervoltage setting (U<) 260V – 360V AC
    Overvoltage setting (U>) 400V – 460V AC
    Phase sequence monitoring Yes
    Trip delay 0.1 – 10 seconds (adjustable)
    Reset Automatic (Auto Reset)
    Indication LED
    Relay output 1-SPDT (1 changeover contact)
    Contact load 5A / 250V AC (resistive load)
    Electrical durability at rated AC1 load 1x105 cycles
    Operating temperature -20°C ~ +55°C
    Mounting 35mm DIN rail
    Cable cross-section Up to 2.5mm²
    Operating altitude <2000m above sea level
    Weight <250g

    Advantages / Benefits

    • Monitors both undervoltage and overvoltage in a three-phase network with a single device.
    • Integrated phase sequence monitoring helps protect three-phase motors against incorrect rotation direction.
    • Adjustable undervoltage protection threshold from 260V to 360V AC.
    • Adjustable overvoltage protection threshold from 400V to 460V AC.
    • Adjustable 0.1 – 10 second delay reduces the likelihood of unnecessary trips caused by short-term mains fluctuations.
    • Automatic reset once the mains fault has been cleared.
    • 1-SPDT changeover relay contact provides flexible integration into contactor and automation control circuits.
    • Standard 35mm DIN rail mounting in control and distribution panels.

    Disadvantages / Limitations

    • Neutral conductor required: the device is designed for a 3x380V AC network with neutral connection.
    • Limited relay contact load: the output contact is rated for up to 5A / 250V AC resistive load, therefore a contactor must be used to control higher-power loads.
    • Not suitable for humid environments: the device must not be operated in locations where it is directly exposed to moisture or water.
    • Incorrect phase sequence blocks the relay: the output will not be activated until the phases are connected in the correct sequence.

    What is it suitable for? (Applications)

    • Protection and control circuits for three-phase electric motors
    • Pump and compressor control systems
    • Industrial automation and control cabinets
    • Equipment sensitive to excessively high or low mains voltage
    • Systems where the correct L1-L2-L3 phase sequence must be monitored
    • Contactor control circuits in three-phase electrical systems

    What is it not suitable for?

    • Monitoring single-phase 230V AC circuits
    • Three-phase networks without the required neutral connection
    • Direct switching of high-power motors or other loads without a contactor
    • Direct installation in humid locations without a suitable protective enclosure

    Practical example

    In an industrial system, a three-phase electric motor is controlled through a contactor. This voltage and phase sequence control relay is installed in the control panel. For example, the undervoltage threshold is set to 330V, the overvoltage threshold to 430V, and the trip delay to 2 seconds. When the mains voltage is within the configured range and the L1-L2-L3 phase sequence is correct, the relay activates the contactor control circuit and the motor can operate. If the voltage drops below 330V, rises above 430V, or the phase sequence changes, the relay output switches off and the contactor disconnects the motor. Once the mains parameters return to normal, the relay automatically restores operation.

    Frequently Asked Questions (FAQ)

    What type of electrical network is this relay designed for?

    The relay is designed for a three-phase 3x380V AC network with neutral connection and operates at a frequency of 50/60Hz.

    Can the undervoltage protection threshold be adjusted?

    Yes. The U< protection threshold can be adjusted from 260V to 360V AC.

    Can the overvoltage protection threshold be adjusted?

    Yes. The U> protection threshold can be adjusted from 400V to 460V AC.

    Does the relay monitor the phase sequence?

    Yes. If the L1, L2, and L3 phase sequence is incorrect, the relay output is not activated.

    Can the trip delay be adjusted?

    Yes. The trip delay can be adjusted from 0.1 to 10 seconds.

    Does the relay need to be manually reset after a voltage fault?

    No. The device has an automatic reset function and automatically restores relay operation once the mains parameters return to the permitted range.

    Can a three-phase motor be controlled directly?

    The relay output contact is rated for up to 5A / 250V AC resistive load. For three-phase motors and other higher-power loads, it is recommended to use the relay output to control the contactor coil.

    Important safety note for the installer

    Use the device according to its intended purpose and wiring diagram. Do not use it in a humid environment. Provide a separate switch and automatic circuit breaker in the installation circuit. They must be installed near the device, in a location easily accessible to the operator, and marked as the means for disconnecting the device from the electrical circuit.

    Maintenance

    Before performing maintenance or cleaning, switch off the device power supply and disconnect it from the electrical circuit. Clean the housing with a soft cloth. Do not use conductive materials or chemical cleaners that may damage the housing or electronic components. After cleaning, make sure that the device operates correctly.

    Three-phase voltage and phase sequence control relay – a practical solution for protecting three-phase electrical systems against overvoltage, undervoltage, and incorrect phase sequence, suitable for motor, pump, compressor, and industrial automation control circuits.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.