CO₂ sensor guide: a monitor for your home or a sensor to control ventilation
This guide gives you quick selection by situation, CO₂ limits according to EN 16798-1, risk zones for people in schools and kindergartens, particulate matter (PM2.5, PM10) limits, a comparison matrix of all the main sensors in this category, an explanation of signals (0–10 V, 4–20 mA, Modbus), common mistakes and answers to practical questions. Exact specifications are given in each product description.
Colour key: ■ information · ■ benefit, solution · ■ ⚠ check · ■ ⚡ safety, mistakes
What do you need? Quick selection
|
Situation |
Solution |
Where to look |
|
Bedroom or child's room: you want to know when to open the window |
Stationary CO₂ monitor with an NDIR sensor and phone notifications |
SAWF-08P, ES-TWNC5000, ES-H900CO2 |
|
Office, classroom, meeting room |
Monitor with a clear display and audible alarm, so everyone ventilates, not just the owner |
ES-TWNC5000, DM176, ES-MCH3B |
|
After renovation, new furniture, odours |
Multifunction monitor: CO₂ plus TVOC and formaldehyde (HCHO) |
ES-IAQM-129-B, ES-A200-CM |
|
On-site inspections, car |
Portable battery-powered monitor measuring CO₂ and CO |
ES-PT04 |
|
Quick check of several rooms, no app needed |
Portable 5-in-1 indicative monitor with battery: CO₂, TVOC, HCHO, temperature and humidity |
TTAKA7 B / TTAKA7 J |
|
Heat recovery unit or fan with a 0–10 V input |
Room CO₂ sensor with analogue output and 24 V supply |
RSMFF-3, RSMFG-3, RCMFG-3 |
|
Flush-mounted box, 230 V only |
Flush-mounted CO₂ controller with 85–264 VAC supply |
FCMF8-R |
|
Ventilation of a whole floor or zone based on extract air |
Duct CO₂ sensor in the extract duct |
DSCDG3-4, DCMFG-2R, ES-LFG202 |
|
Building automation (BMS) via Modbus |
Sensor with Modbus RTU (RS485); analogue output not required |
DSCDG0-4, RSMFF-3, ES-YYS |
|
Dust, smoke, fireplace, living next to a busy road |
Particulate matter (PM2.5 / PM10) monitor. A CO₂ monitor does not detect dust |
SAWF-07P, ES-A200-CM |
|
Greenhouse |
CO₂ controller with automatic control and 0–5000 ppm range |
ES-SA-1600P |
|
Gas boiler, fireplace, stove |
⚡ You need a CO (carbon monoxide) detector, not a CO₂ monitor |
ES-PTH-21D, ES-PT04 |
Ventilate when needed, not by the clock
CO₂ concentration shows how much exhaled air has built up in a room. A monitor reminds you to open the window when the air gets stuffy, while a sensor in the ventilation system increases airflow only when people are in the room.
-
At home: better sleep and fewer headaches in closed rooms.
-
In offices and classrooms: attention and productivity, especially in the afternoon.
-
In ventilation systems: lower heating and electricity costs, because the fan does not run at full capacity in an empty room.
Monitor or control: two different product groups
Both groups measure CO₂; the difference is where the reading goes. A monitor shows it to people, while a sensor sends a signal to the ventilation equipment.
■ CO₂ monitor: for home, office, classroom
-
Display, app or audible alarm.
-
Powered via USB or battery, no installation needed.
-
Range typically 400–5000 ppm.
-
Smart models connect via Tuya or Matter (Apple Home, Google Home, Alexa).
■ CO₂ sensor: for ventilation automation
-
Analogue output 0–10 V, 0–20 / 4–20 mA or PWM.
-
Modbus RTU (RS485) for building automation.
-
Supply 24 V AC/DC or 230 V, installed by an electrician.
-
Room, flush-mounted or duct housing.
How much CO₂ is too much? Limits and recommendations
CO₂ is measured in ppm (parts per million). Outdoor air contains about 400 ppm, so an indoor reading is never lower. The European standard EN 16798-1 classifies ventilation quality into categories based on how much CO₂ builds up indoors above the outdoor level.
Outdoor air
~400 ppm
Lowest possible indoor reading
Category I
up to ~950 ppm
High expectations: classrooms, sensitive people
Category II
up to ~1200 ppm
Normal level for new buildings
Category III
up to ~1750 ppm
Acceptable, but already stuffy
Category IV
above 1750 ppm
Poor air quality, drowsiness, headaches
Scale 400–2400 ppm. Absolute values calculated for outdoor air at ~400 ppm. The standard applies stricter limits to bedrooms.
|
Room |
Recommended limit |
How to set it |
|
Bedroom, child's room |
800–1000 ppm |
Phone notification or ventilation boost from 900–1000 ppm |
|
Living rooms, office |
~1000 ppm |
Ventilation starts ramping up at about 800 ppm, full capacity at 1200 ppm |
|
Classroom, meeting room |
950–1000 ppm |
Audible alarm or automatic ventilation, as occupancy is high and CO₂ rises fast |
|
Greenhouse |
Depends on the crop |
Often 800–1200 ppm with CO₂ dosing. Here the sensor controls the CO₂ supply as well, not just ventilation |
In practice: start with a 1000 ppm limit and monitor readings for a week. If the air is still stuffy in the evening, lower the limit in 100 ppm steps.
⚡ Risk zones for people: schools and kindergartens
In a classroom or kindergarten group, 20–30 people breathe in a small space at the same time, so CO₂ rises several times faster than in a flat. In a 2019 study by the Lithuanian National Passive House Association, the average CO₂ concentration during lessons in 11 Vilnius schools reached 1660 ppm. In primary classrooms readings rose to 3183 ppm, in senior classes to 5152 ppm. Such concentrations exceed even the 8-hour workplace limit for adults.
|
CO₂ |
Zone |
Effect on people |
|
up to 1000 ppm |
Safe zone |
Good conditions for learning and working. Target for classrooms and bedrooms |
|
1000–1400 ppm |
Caution zone |
Attention and concentration decline, drowsiness sets in. Studies show decision-making quality starts to deteriorate from ~1000 ppm |
|
1400–2500 ppm |
Ventilation required |
Headaches, fatigue, stuffiness. Children remember less and tire faster |
|
2500–5000 ppm |
Unacceptable for a learning space |
Severe fatigue and headaches. Such concentrations indicate that ventilation is not working or is completely inadequate |
|
5000 ppm |
Workplace 8 h limit |
Long-term exposure limit for an adult worker: NIOSH and OSHA 5000 ppm, EU: 9000 mg/m³ |
|
30 000 ppm |
Short-term exposure limit |
No longer than 15 min (NIOSH). Shortness of breath, increased heart rate |
|
40 000 ppm |
Immediately dangerous to life |
NIOSH IDLH limit. Indoors this occurs only with a CO₂ leak: cellars with CO₂ cylinders, refrigeration equipment, dry ice, fermentation |
At these concentrations CO₂ is not poisonous like carbon monoxide, but it is the most reliable indicator that exhaled air, moisture, viruses and other pollutants are building up in a room. Relative to body weight, children inhale more air than adults, so they are also more sensitive to particulate matter.
|
Room |
Risk |
Solution |
Where to look |
|
Classroom |
CO₂ can exceed 2000 ppm during a 45-minute lesson |
A monitor in every classroom with a clear display and audible alarm; ventilate during every break |
DM176, ES-TWNC5000 |
|
Kindergarten group room and nap room |
During the afternoon nap in a closed room, CO₂ rises unnoticed |
Monitor with phone notifications for staff; CO₂-controlled ventilation in the nap room |
SAWF-08P, ES-TWNC5000 |
|
Gym, assembly hall |
Many people and high physical exertion |
Duct CO₂ sensor in the extract air, ventilation speed based on CO₂ |
DSCDG3-4, RSMFF-3 |
|
After renovation, new furniture |
Formaldehyde (HCHO) and TVOC from paints, adhesives and furniture |
Multifunction monitor before children return |
ES-IAQM-129-B, ES-A200-CM |
|
Kitchen with gas appliances |
Carbon monoxide (CO) from poor combustion |
CO detector near the gas appliances |
ES-PTH-21D |
|
Heating season, school next to a road |
Outdoor PM2.5 enters through the windows |
PM monitor, heat recovery unit with a high-grade filter |
SAWF-07P, ES-A200-CM |
⚡ Installation in childcare facilities: Fazė's tip
-
Mount the monitor out of children's reach, at about 1.5 m on an interior wall. Secure the power cables so they cannot be pulled.
-
Use battery-powered devices only if the battery compartment can be closed securely. Do not keep spare batteries in children's rooms.
-
In a classroom, choose a monitor with clear indication that everyone can see: green, yellow, red or an audible alarm.
-
Readings must be visible to staff, not just to the device owner. Smart monitors send notifications to a phone.
-
230 V equipment and ventilation automation must be connected by a qualified electrician.
Particulate matter (PM2.5, PM10): what a CO₂ monitor does not show
Particulate matter is dust, soot and smoke particles suspended in the air. PM10 are particles up to 10 µm in diameter, PM2.5 up to 2.5 µm. Fine PM2.5 particles penetrate deep into the lungs, making them the most harmful to health. CO₂ shows whether a room is ventilated enough, while PM shows whether the air is clean. These are two different measurements, and one does not replace the other.
|
Indoor source |
What to do |
|
Cooking, especially frying or grilling |
Switch on a cooker hood that vents outdoors and ventilate briefly but intensively |
|
Fireplace, stove, candles, incense |
Watch the PM2.5 reading. A reading that stays high means poor draught or leaks |
|
Outdoor pollution: roads, solid-fuel boiler houses in the heating season |
When outdoor PM is high, airing through the window makes indoor air worse. A heat recovery unit with a high-grade filter (ePM1 per ISO 16890) helps |
|
Renovation, sanding, construction |
Measure before and after the work. In industry, dust is monitored by fixed sensors with signal output |
Limits (µg/m³)
|
Indicator |
WHO guideline (2021) |
EU limit from 2030 (Directive 2024/2881) |
|
PM2.5 annual |
5 |
10 |
|
PM2.5 daily |
15 |
25, may be exceeded up to 18 days per year |
|
PM10 annual |
15 |
20 |
|
PM10 daily |
45 |
45, may be exceeded up to 18 days per year |
These limits apply to outdoor air. There are no mandatory PM limits for indoor spaces, so use the WHO guidelines as a reference. Short spikes while cooking are normal; what matters is that the reading drops back quickly.
|
For |
Solution |
Where to look |
|
Home, office: PM2.5 and PM10 on your phone |
Smart PM monitor with 3-level warning, Apple Home, Google Home, Alexa |
SAWF-07P |
|
Complete air quality monitoring in one device |
8-in-1 analyser: CO₂, PM2.5, PM10, TVOC, T, RH and AQI |
ES-A200-CM |
|
Production, warehouse, workshop |
Industrial PM1.0 / PM2.5 / PM10 sensor with 4–20 mA, RS485 and IP67 |
ES-YA-FD100 |
Selection matrix: the main sensors in this category
The table lists key specifications from manufacturer data. The category contains more models; these represent each use case.
|
Product |
Type |
Measures |
Output / communication |
Power supply |
|
Monitors: display and notify |
|
Sonoff AirGuard CO₂ SAWF-08P |
Stationary, smart |
CO₂ (NDIR), temperature, humidity |
Matter over Wi-Fi: Apple Home, Google Home, Alexa |
see description |
|
ES-TWNC5000 |
Stationary, smart |
CO₂ (NDIR) 400–5000 ppm, T, RH |
Wi-Fi, Tuya |
Battery 1600 mAh |
|
ES-H900CO2 |
Stationary, smart |
CO₂, temperature |
Wi-Fi, Tuya |
see description |
|
ES-MCH3B |
Stationary, smart |
CO₂ 500–5000 ppm |
Tuya |
5 V DC |
|
DM176 |
Mini, desktop |
CO₂ (NDIR) 400–5000 ppm |
LED display, audible alarm |
see description |
|
ES-IAQM-129-B |
Multifunction |
CO₂ 400–5000 ppm, TVOC, HCHO, T, RH |
Wi-Fi, Tuya |
see description |
|
ES-PT04 |
Portable |
CO₂, CO, temperature, humidity |
Bluetooth, USB |
Battery |
|
TTAKA7 B / TTAKA7 J |
Portable, indicative |
CO₂ up to 5000 ppm, TVOC, HCHO, T, RH |
Colour display, no connectivity |
Battery 2000 mAh |
|
Sonoff AirGuard SAWF-07P |
Stationary, smart |
PM2.5, PM10, T, RH (no CO₂) |
Wi-Fi: Apple Home, Google Home, Alexa |
see description |
|
ES-A200-CM |
8-in-1 analyser |
CO₂ (NDIR), PM2.5, PM10, TVOC, T, RH, AQI |
Audible and visual alarm, data logging |
see description |
|
Sensors for ventilation control |
|
RSMFF-3 |
Room transmitter |
CO₂ 400–2000 ppm, T, RH |
3 × 0–10 V / 0–20 mA / PWM, Modbus RTU |
24 V DC |
|
RSMFG-3 |
Room transmitter |
CO₂ 400–2000 ppm, T, RH |
3 × 0–10 V / 0–20 mA / PWM, Modbus RTU |
24 V AC/DC |
|
RCMFF-3 |
Room sensor-controller |
CO₂ 400–2000 ppm, T, RH |
0–10 V / 0–20 mA / PWM, Modbus RTU |
24 V DC |
|
RCMFG-3 |
Room sensor-controller |
CO₂ 400–2000 ppm, T, RH |
0–10 V / 0–20 mA / PWM, Modbus RTU |
24 V AC/DC |
|
FCMF8-R |
Flush-mounted sensor-controller |
CO₂ 400–2000 ppm, T, RH |
0–10 V / 0–20 mA / PWM, Modbus RTU |
85–264 V AC |
|
FCMFG-R |
Flush-mounted sensor-controller |
CO₂ 400–2000 ppm, T, RH |
0–10 V / 0–20 mA / PWM, Modbus RTU |
24 V AC/DC |
|
DSCDG3-4 |
Duct, IP54 |
CO₂ (NDIR) 0–2000 ppm, T, RH |
3 × 0–10 V / 4–20 mA / PWM, Modbus RTU |
24 V AC/DC |
|
DSCDG0-4 |
Duct, IP54 |
CO₂ (NDIR) 0–2000 ppm, T, RH |
Modbus RTU only |
24 V AC/DC |
|
DCMFG-2R |
Duct sensor-controller, IP54 |
CO₂ 0–2000 ppm, T, RH |
0–10 V / 0–20 mA / PWM, Modbus RTU |
24 V AC/DC |
|
ES-LFG202 |
Duct, IP65 |
CO₂ |
RS485, 4–20 mA, 0–10 V |
16–30 V DC |
|
LFG201 |
Sensor |
CO₂ 0–10 000 ppm |
0–10 V |
16–30 V DC |
|
ES-YYS |
Wall-mounted with transmitter |
CO₂ 400–5000 ppm and air quality |
RS485, 4–20 mA |
see description |
|
Special applications |
|
ES-SA-1600P |
CO₂ controller |
CO₂ 0–5000 ppm, T, RH |
Automatic control, LCD, audible and visual alarm |
see description |
|
Room VOC sensor |
Room VOC |
Volatile organic compounds (VOC) |
4–20 mA, 0–10 V, Modbus RS485 |
see description |
|
Duct VOC sensor |
Duct VOC |
VOC in extract air |
4–20 mA, 0–10 V, Modbus RS485 |
see description |
|
Duct VOC sensor with LCD |
Duct VOC with LCD |
VOC, local display |
4–20 mA, 0–10 V, Modbus RS485 |
see description |
|
CO detector ES-PTH-21D |
CO detector, portable |
CO (carbon monoxide) 0–1000 ppm, T, RH |
Display, alarm |
Battery |
|
ES-YA-FD100 |
Industrial, IP67 |
PM1.0, PM2.5, PM10, HCHO, TVOC |
4–20 mA, RS485, alarm |
see description |
“See description” means the parameter is given on the product page. The 3 outputs of Sentera sensors are dedicated to CO₂, temperature and humidity respectively. The output type (0–10 V, mA or PWM) is selected in the settings.
Signals and communication: 0–10 V, 4–20 mA, Modbus or relay
|
Signal |
When to choose |
What to watch for |
|
0–10 V |
Heat recovery units, EC fans, frequency inverters with analogue input |
The most common option. Check that the device accepts exactly 0–10 V, not 2–10 V |
|
4–20 mA |
Long cable runs, industry, electrically noisy environments |
A current signal is less sensitive to cable length and interference than a voltage signal |
|
PWM |
Some EC fans |
Suitable only if the fan input is designed for PWM |
|
Modbus RTU (RS485) |
Building automation (BMS), several sensors on one line |
Address and communication parameters must be set. Use twisted-pair cable |
|
Relay / automatic control |
Greenhouses, simple on/off switching at a threshold |
Check the relay load rating. Switch larger motors via a contactor |
Controlling the fan via a frequency inverter (VFD)? The 0–10 V CO₂ signal can be connected directly to the inverter's analogue input. See the wiring diagram in the frequency inverters category.
Wiring diagrams: sensor, controller and Modbus
The four most common integration scenarios. Terminal names depend on the model, so always check the instructions for the product and the controlled device when wiring.
Room transmitter RSMFF-3 or RSMFG-3 is powered from the heat recovery unit's 24 V output, and the CO₂ signal (AO3) goes to its 0–10 V input.
Sensor-controller RCMFG-3 generates the fan speed signal itself. Suitable for a frequency inverter with a 0–10 V analogue input or an EC fan.
Modbus RTU line with RSMFF-3, DSCDG0-4 and ES-LFG202. Devices are connected in a daisy chain, with 120 Ω termination resistors at both ends.
A duct sensor is installed in the extract duct; a room sensor on an interior wall at 1.2–1.5 m.
FazėBefore connecting a sensor, I always check three things in the controlled device's manual: the input type (0–10 V or 2–10 V), whether it provides a 24 V supply, and whether GND is common to signal and power.
⚠ What to check before buying
KibirkštisBefore buying a CO₂ sensor, I always clarify three things: where the reading will be sent, what power supply is available on site, and what signal the controlled device expects.
|
What to check |
Why it matters |
|
Sensor type: NDIR |
An NDIR sensor measures CO₂ optically, accurately and stably. Cheap “eCO₂” sensors only estimate CO₂ from VOC and can be inaccurate |
|
Range |
400–2000 ppm is enough for rooms. Greenhouses and industry need 0–5000 ppm or more |
|
Output and communication |
Must match the input of the heat recovery unit, controller or BMS: 0–10 V, mA, PWM or Modbus |
|
Power supply |
24 V AC and 24 V DC are not the same. There are models for 24 V DC only, 24 V AC/DC and 230 V |
|
Mounting location |
A room sensor measures one room; a duct sensor measures extract air from the whole zone |
|
Automatic calibration |
Most sensors self-calibrate and expect the room to be ventilated down to outdoor air level at least occasionally |
✗ Common mistakes
|
Mistake |
Consequence |
|
A CO₂ monitor is placed next to a gas boiler as “carbon monoxide protection” |
A CO₂ monitor does not detect carbon monoxide (CO). A life-threatening hazard goes unnoticed |
|
The sensor is installed next to a window, door or directly above a desk |
Readings jump due to draughts or people's breath, and ventilation runs erratically |
|
A 24 V DC sensor is connected to a 24 V AC transformer |
The sensor does not work or fails. Choose an AC/DC version or a suitable power supply |
|
The 0–10 V analogue signal is routed together with 230 V cables |
Interference, the fan speed “hunts”. Use shielded cable and a separate route for the signal |
|
A monitor without NDIR is chosen because it is cheaper |
Inaccurate readings, people stop trusting the device and stop ventilating |
|
Expecting a CO₂ monitor to show dust or smoke |
CO₂ and particulate matter are different measurements. Dust needs a PM sensor |
|
A duct sensor is installed in the supply duct |
It measures fresh air, so the system does not “see” room CO₂. The sensor must be in the extract duct |
⚡ CO₂ ≠ CO and safe installation: Fazė's tip
-
CO₂ (carbon dioxide) indicates ventilation quality. CO (carbon monoxide) is a poisonous gas. Next to a boiler, fireplace or stove you need a CO detector.
-
Disconnect power to the controller and the heat recovery unit before connecting the sensor.
-
230 V flush-mounted controllers and power supplies must be connected by a qualified electrician.
-
Connect signal and power wires according to the manufacturer's diagram, as fan inputs differ.
☝ Elsprendimai.eu recommends: mount a room CO₂ sensor at 1.2–1.5 m on an interior wall, away from windows, doors, radiators and direct sunlight. This is the height at which people breathe.
Frequently asked questions
Questions from Kibirkštis, a young and curious electrician. Answers from Fazė, an experienced elsprendimai.eu specialist.
KibirkštisWhat CO₂ limit should I set for ventilation?
FazėFor most rooms, 1000 ppm is a good starting point. For classrooms and bedrooms, a lower limit of about 900–950 ppm is worth choosing. In systems with 0–10 V control, ventilation is often set to start ramping up at 800 ppm and run at full capacity at 1200 ppm.
KibirkštisWill a CO₂ monitor detect carbon monoxide?
FazėNo. CO₂ and CO are different gases and are measured by different sensors. Next to a gas boiler or fireplace you need a
CO detector. If you want one portable device for both gases, choose the
ES-PT04.
KibirkštisWhat is the difference between a transmitter and a sensor-controller?
FazėA transmitter, e.g. the
RSMFF-3, only passes on measurements: CO₂, temperature and humidity as three separate signals. The heat recovery unit or controller makes the decision. A sensor-controller, e.g. the
RCMFG-3, generates the fan control signal itself based on the set threshold.
KibirkštisCan I connect a CO₂ sensor to my heat recovery unit?
FazėIn most cases yes, if the heat recovery unit has a 0–10 V or Modbus input for a CO₂ sensor. Check the unit's manual: what signal it accepts and whether it can supply the sensor with 24 V.
KibirkštisWhy does the monitor show more than 400 ppm in an empty room?
FazėCO₂ does not disperse immediately after people leave; in a closed room it takes several hours. If the reading stays high even after ventilating, recalibrate the sensor in outdoor air according to the manufacturer's instructions.
KibirkštisIs it worth ventilating when outdoor pollution is high?
FazėIn the heating season and near busy roads, outdoor PM2.5 is sometimes higher than indoors. Then it is better to open the window briefly rather than leave it ajar. The best solution is a heat recovery unit with a good filter plus a PM monitor, such as the
SAWF-07P, which shows when the outdoor air is cleaner.
KibirkštisHow many CO₂ monitors does a school or kindergarten need?
FazėOne in each classroom or group room, as CO₂ rises differently in different rooms. A shared sensor in the corridor does not reflect classroom air. If the building has mechanical ventilation, it is worth installing duct sensors in the extract so the system increases airflow automatically.
KibirkštisRoom or duct sensor?
FazėA room sensor controls based on a single room, so it suits a flat, meeting room or classroom. A duct sensor in the extract duct measures the average of all rooms in the zone and is simpler to install when one system serves several rooms.
KibirkštisCan you help select a sensor for a specific heat recovery unit?
FazėYes. Send us the model of your heat recovery unit or controller and a description of the rooms. We will select a compatible sensor, power supply and cable and send you a quotation.
Sources
Manufacturer data and standards used in this guide. Verified 2026-10-29.
This guide is for orientation only; make your final decision based on the manufacturer's datasheet and your system requirements. UAB “Elektrotechnikos sprendimai” accepts no liability for product selection based on this guide.
CO₂ sensor, power supply and control in one order
CO₂ monitors, ventilation sensors, VOC and CO sensors, frequency inverters and power supplies in one place. Send us the model of your heat recovery unit or fan and the required control logic: we will select compatible components and send you a quotation. Can't find the model you need in the catalogue? Some products are supplied to order.