Mechanical bolted ring cable lug | 70–120 mm² | M12 | Al/Cu | up to 12 kV | Raychem | EXRM-1235-70/120-SK12
Code: EXRM-1235-70/120-SK12Price 7.16 € VAT incl.( 5.92 € VAT excl. )Mechanical bolted ring cable lug for 70–120 mm² round Al and Cu conductors, M12 palm, 2 clamping bolts, up to 12 kV (supplier data). Installed without a crimping tool.
-
Mechanical bolted ring cable lug | 70–120 mm² | M12 | Al/Cu | up to 12 kV | Raychem | EXRM-1235-70/120-SK12
EXRM-1235-70/120-SK12 is a mechanical bolted ring cable lug for connecting 70–120 mm² round aluminium and copper conductors to an M12 bolted terminal. The conductor is clamped in the barrel by two clamping bolts, so no crimping tool or dies are required. According to supplier data, the lug is intended for 1 kV and up to 12 kV cables; the body is tin-plated aluminium.
Key point:
One lug covers the entire 70–120 mm² range, so instead of 3 crimp lug sizes you need only one code in stock and in the crew van. A practical solution for emergency repairs, refurbishments and sites where a press for large cross-sections is simply not at hand.Cross-section
70–120 mm², round conductorsPalm hole
M12Conductors
Al / CuVoltage class
1 kV, up to 12 kV (supplier data)How it works
The conductor insulation is stripped to the depth of the lug barrel, and the surface of an aluminium conductor is cleaned of oxide. The conductor is pushed fully into the barrel.
The two clamping bolts are tightened alternately so that the conductor is clamped evenly along the full contact length. If the bolts have shear-off heads, tighten until the head breaks off; otherwise tighten to the torque specified by the supplier.
The ring palm with a hole for an M12 bolt is fixed to a busbar, switch-disconnector, transformer or equipment terminal. The result is a reliable electrical and mechanical connection without a crimping tool and without selecting a die for each cross-section.
What makes EXRM-1235-70/120-SK12 useful?
One lug covers 70, 95 and 120 mm² cross-sections. The installer needs only a socket or spanner, and contact quality does not depend on the condition of a press or on choosing the right die.Technical specifications
Product type Mechanical bolted ring cable lug Model EXRM-1235-70/120-SK12 Conductor cross-section 70–120 mm² Conductor shape Round Conductor material Al / Cu, per supplier specification Palm (terminal) size M12 Installation method Bolted clamping Number of clamping bolts 2 Voltage class stated by supplier 1 kV, up to 12 kV Body material Aluminium, per supplier data Surface Tin-plated, per supplier data Installation tool Socket / spanner, no press required Main features
- Wide 70–120 mm² range – one code for 3 standard cross-sections, smaller stock.
- Bolted clamping – no crimping tool or dies needed.
- Two clamping bolts – even clamping along the long barrel contact.
- Al and Cu conductors – suitable for both conductor types per supplier specification.
- M12 ring palm – standard connection to busbars, switch-disconnectors and equipment terminals.
- Tin-plated aluminium body – slower oxidation at the contact point.
Where is it used?
- 0.4 kV cable incomers and outgoers in transformer substations
- Distribution and metering cabinets
- 10 kV cable ends – together with an appropriate termination kit
- Main incoming panels and busbar systems in industrial plants
- Cable line repairs and refurbishments
- Connecting solar and wind farm cables
- Generator and backup power incomers
- Emergency work when no crimping tool is available on site
Use by need
For grid contractors.
One lug for several cross-sections – fewer codes in the crew van and faster emergency repairs.For industrial plant energy managers.
Reconnecting the main incoming cable without renting a press, when downtime costs more than the lugs.For panel builders.
Connecting large Al and Cu cables to busbars when the exact cable size is only known on site.Practical application
If, during the refurbishment of a 0.4 kV distribution cabinet, it turns out that the cables are 1×95 mm² Al with round conductors, while the crew only has 70 mm² crimp lugs and dies, EXRM-1235-70/120-SK12 lets the work continue the same day: the conductors are cleaned, inserted into the lugs, clamped with the bolts and connected to the busbar with M12 bolts.Advantages
- One lug for the 70–120 mm² range
- No crimping tool or dies needed
- Suitable for Al and Cu conductors
- Two clamping bolts – even contact
- Standard M12 connection
- Voltage class stated by supplier – up to 12 kV
- Fast installation in emergency situations
Disadvantages / limitations
- Designed for round conductors – for sector conductors choose the sector version
- M12 palm hole – if the terminal bolt is a different size, choose another version (the range includes M10 and M12)
- On 6–12 kV cables the lug does not replace a cable termination – an appropriate kit is required
- Mechanical lugs are usually bulkier than crimp lugs – check the space in the terminal compartment
Safety and installation notes
- Work only after the line is isolated, earthed and verified dead; work must be carried out by qualified personnel.
- Strip insulation exactly to the barrel depth – no bare conductor may remain outside the lug and no insulation may enter the barrel.
- Clean oxide from aluminium conductors; use contact grease if required.
- Tighten the bolts alternately – do not fully tighten one before the other.
- Do not use impact tools or extension levers unless the supplier states otherwise.
- After installation, restore insulation with heat-shrink tubing or a termination kit.
- Do not reuse a lug once it has been removed.
Quick selection guide
70–120 mm²M12Al / CuRound conductor2 boltsUp to 12 kVSuitable when you need to:- connect 70–120 mm² round Al or Cu conductors
- work without a crimping tool
- keep one code for several cross-sections
- carry out an emergency repair quickly
Check before use:- conductor shape – round or other
- equipment terminal bolt size (M12)
- space in the terminal compartment
- cable voltage class and termination kit
Important reminder: The lug only connects the conductor to the terminal – it does not replace a medium-voltage cable termination, screen earthing or insulation restoration.FAQ
Is the lug suitable for a sector conductor?
No, this version is designed for round conductors – for sector conductors choose a sector mechanical lug.Is a press needed for installation?
No, the conductor is clamped by two bolts; a socket or spanner is enough.Is it suitable for copper conductors?
Yes, the supplier states that the lug is suitable for Al and Cu conductors.What does M12 mean?
It is the palm hole size for fixing with an M12 bolt to a busbar or terminal.Can it be used on a 10 kV cable?
The supplier states a voltage class of up to 12 kV, but the cable end must be finished with an appropriate termination.Which cross-sections does it fit?
Standard 70, 95 and 120 mm² cross-sections.EXRM-1235-70/120-SK12 | 70–120 mm² | M12 | Al/Cu | mechanical
Mechanical bolted ring cable lug for 70–120 mm² round Al and Cu conductors with an M12 palm – connection without a press, one code for 3 cross-sections. Suitable for 1 kV and up to 12 kV cable lines in substations, distribution cabinets and industrial incomers.
Published: 2026-11-03 · Data verified against supplier specification: 2026-11-03
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Aluminium power cable | 4x150mm² | AXMK | Class 2 | 500m | blackCode: SKU#165996595240116261Aluminium power cable AXMK 4×150 mm², designed for fixed 0.6/1 kV electrical power transmission and distribution lines. The cable features aluminium conductors, XLPE insulation, and a black PVC outer sheath resistant to UV radiation. Suitable for installation outdoors, underground, in dry, damp and wet areas, cable ducts, pipes, and concrete. Maximum operating temperature – 90 °C.
Sold by the drum, i.e. the minimum order quantity is 500 metres.
Delivery time: up to 6 weeks.
Price 14.52 € VAT incl.( 12.00 € VAT excl. )Aluminium power cable | 4x120mm² | AXMK | Class 2 | 1000m | BlackCode: SKU#165996553256573221AXMK 4×120 mm² aluminium power cable designed for fixed 0.6/1 kV electrical power transmission and distribution lines. The cable features aluminium conductors, XLPE insulation, and a black UV-resistant PVC outer sheath. Suitable for installation outdoors, underground, in dry, damp and wet areas, cable ducts, conduits, and concrete. Maximum operating temperature – 90 °C.
Sold by the drum, i.e. the minimum order quantity is 1000 metres.
Delivery time: up to 6 weeks.
Price 11.04 € VAT incl.( 9.12 € VAT excl. )Single-cable membrane entry flange | for Ø86 mm hole | cable Ø55–70 mm | flange Ø123.1 mm | grey | IP67 | HT Hi Tech Polymers | HTX-1Code: Sandariklis HTX-1HTX-1 is a membrane entry flange for one thick power cable Ø55–70 mm. It fits a round Ø86 mm hole in the enclosure wall, flange diameter Ø123.1 mm. Sealing rating is IP67 according to the latest manufacturer's sheet.
Price 21.78 € VAT incl.( 18.00 € VAT excl. )CYKY-L 5G10 | 5×10 mm² | Copper power cable | 450/750 V | black | 1 m | LietkabelisCode: 91951013CYKY-L 5G10 (5×10 mm²) – 450/750 V copper power cable for three-phase 400 V circuits with neutral. Solid cores, PVC insulation and sheath, suitable indoors, outdoors and in the ground. AB Lietkabelis, price per 1 m.
Price 8.67 € VAT incl.( 7.17 € VAT excl. )CYKY-J 5G16 | 5×16 mm² | Copper power cable | 0.6/1 kV | black | 1 m | NKTCode: C520218CYKY-J 5G16 (5×16 mm²) – 0.6/1 kV copper power cable for three-phase 400 V circuits with neutral. Solid cores, PVC insulation and sheath, suitable indoors, outdoors and in the ground. NKT, price per 1 m.
Price 15.00 € VAT incl.( 12.40 € VAT excl. )Modular three-phase smart energy meter with relay | 60 A | 3×230/400 V | Wi-Fi Tuya | remote control | U/I protection | RS485 | DIN | Tomzn TO-DTS238Code: TO-DTS238Three-phase DIN meter with a built-in relay for 3×230/400 V networks up to 60 A. Via Wi-Fi and the Tuya app it shows U, I, P, PF, frequency and imported / exported energy separately, and lets you switch the supply on / off remotely, set a timer and configure voltage / overload protection. It also has RS485 Modbus RTU; intended for non-billing (internal) metering.
Price 145.20 € VAT incl.( 120.00 € VAT excl. )