Products catalog

Copper power supply cables H03VV-F, H05VV-F

  • KibirkštisFazė

    H03VV-F (300/300 V) and H05VV-F (300/500 V; also known as OMY and OWY) – flexible copper cables with PVC insulation and sheath for connecting household appliances, luminaires and office equipment. H03VV-F suits light loads, H05VV-F – medium ones. Sold by the metre. Below the products – H03 vs H05 comparison, size matrix, current, length and voltage drop tables and a common-mistakes diagram.

     
    Read more
  • Flexible copper cables · appliance connection

    H03VV-F and H05VV-F (OMY, OWY) | 300/300 V and 300/500 V | selection guide

    Two PVC cables that look alike but have different limits of use. H03VV-F is meant for light mechanical stress, H05VV-F for medium stress and a wider range of household appliances. The guide helps you choose the type, number of cores, cross-section and length, and avoid the most common mistakes.

    H03VV-F
    300/300 V · light duty
    H05VV-F
    300/500 V · medium duty
    Cu · class 5
    flexible copper conductors
    PVC / PVC
    core insulation and sheath
    +70 °C
    maximum conductor temperature
    KibirkštisFazėAsks Kibirkštis – a young electrician who is not afraid to ask. Answered by Fazė – an experienced engineer.
    Key point:
    Both cables are flexible and copper, but suitability is not decided by the conductor alone. H03VV-F choose for lamps, small electronics and other light appliances. H05VV-F – for household appliances and other medium loads, also suitable for 400 V circuits. The choice is always decided by rated voltage, current, number of cores (is PE needed), environment and mechanical stress.
    Information and selection Suitable / recommended ⚠ Check ⚡ Safety and mistakes

    Quick selection by situation

    Typical examples. Always confirm the final choice against the appliance manufacturer's requirements.

    Situation Indicative choice Why
    Table lamp, radio, class II appliance H03VV-F 2×0.5 or 2×0.75 Low power and mechanical stress; no PE needed.
    Small earthed luminaire or appliance H03VV-F 3G0.75 Three cores: L, N and PE.
    Refrigerator, washing machine, dishwasher H05VV-F 3G1 or 3G1.5, per appliance manufacturer Medium mechanical stress, PE for a class I appliance.
    Single-phase appliance with a higher load H05VV-F 3G1.5 or 3G2.5 Cross-section is confirmed by current, length, terminals and protection.
    Appliance with an extra control core H05VV-F 4G0.75 or 4G1 Extra core according to the appliance wiring diagram.
    Three-phase 400 V appliance H05VV-F 4G or 5G, after assessing current and conditions The 300/500 V rating suits a 230/400 V network; H03VV-F does not.
    Permanent outdoor use, construction site, heavy abrasion Not standard H03VV-F / H05VV-F Choose a cable made for the environment, e.g. rubber H07RN-F.
    Fixed installation in walls or underground Not an appliance connection cable Choose NYM-J or CYKY-L.
    ⚠ Check: the table covers the most common cases. The cross-section and cable type are finally decided by the appliance current, length, environment and manufacturer requirements.

    H03VV-F or H05VV-F? Key differences

    Parameter H03VV-F H05VV-F
    Rated voltage U0/U 300/300 V 300/500 V
    Mechanical stress Light Medium
    Conductor Copper, class 5 Copper, class 5
    Insulation / sheath PVC / PVC PVC / PVC
    Maximum conductor temperature +70 °C +70 °C
    Typical appliances Luminaires, small electronics Refrigerators, washing machines, other household appliances
    Number of cores Usually 2–4 Usually 2–5
    Three-phase 400 V Not suitable Possible if current and conditions fit
    Permanent outdoor use Not suitable Not suitable
    Kibirkštis
    KibirkštisBoth cables are copper and soft. Why don't you just recommend H03VV-F for a washing machine?
    Fazė
    FazėBecause the copper conductor is not everything. H03VV-F is meant for light mechanical stress, while washing machines normally get H05VV-F. We confirm the cross-section from the appliance manual and its current.

    Size and purpose matrix

    Standard combinations of type and cross-section. Choose the exact colour, number of cores and available quantity in the product list.

    Cores \ mm² 0,5 0,75 1 1,5 2,5 4
    2 cores H03VV-F H03 / H05 H05VV-F H05VV-F H05VV-F H05VV-F
    3 cores (3G) H03VV-F H03 / H05 H05VV-F H05VV-F H05VV-F H05VV-F
    4 cores (4G) H03VV-F H03 / H05 H05VV-F H05VV-F H05VV-F H05VV-F
    5 cores (5G) – H05VV-F H05VV-F H05VV-F H05VV-F H05VV-F

    Orange cell – H03VV-F available, green – H05VV-F. G means a green-yellow PE core. Flat H05VVH2-F cables are a separate design – check their availability in the product list. A type shown in the matrix does not mean every combination is in stock.

    Where H03VV-F and H05VV-F fit and where they do not

    ✓ Small appliances
    Table lamps, electronics, light appliances – H03VV-F.
    ✓ Household appliances
    Refrigerators, washing machines, other appliances – H05VV-F.
    ✓ Offices and commercial premises
    Office equipment and appliance connection in dry rooms.
    ✓ Flexible connections
    Many fine strands let the cable flex and the appliance be moved.
    ⚠ Damp rooms
    The cable is suitable, but the plug, socket and IP protection must match the location.
    ⚠ Heating appliances
    Only if hot parts do not act on the cable and the appliance design allows it.
    ✗ Permanent outdoor use
    Standard PVC is not made for long exposure to sun, frost and water.
    ✗ Harsh conditions
    For construction sites, heavy abrasion or moving equipment choose a tougher cable.

    What 300/300 V and 300/500 V mean

    Rated voltage is written as U0/U: U0 – between conductor and earth, U – between conductors. In a 230 V single-phase circuit there are 230 V between L and N; in a 230/400 V three-phase circuit there are 400 V between phases.

    H03VV-F – 300/300 V

    For single-phase 230 V connections when mechanical and other conditions of use are met.

    230 V between L and N ✓
    400 V between phases ✗
    H05VV-F – 300/500 V

    For single-phase 230 V and three-phase 230/400 V connections if current, design and conditions fit.

    230 V between L and N ✓
    400 V between phases ✓
    ⚡ Important: the number of cores does not change the rated voltage. H03VV-F 4G0.75 with four cores does not become a 400 V cable. And H05VV-F 300/500 V does not mean it suits every three-phase device – current and conditions matter too.

    How to read the H05VV-F 3G1.5 designation

    H05VVF3G1.5
    Part Meaning
    H Harmonised European designation.
    03 / 05 Rated voltage: 03 – 300/300 V, 05 – 300/500 V.
    First V PVC core insulation.
    Second V PVC outer sheath.
    F Flexible stranded conductor.
    3G1.5 Three cores, one of them green-yellow PE, each 1.5 mm².

    Example: H05VV-F 3G1.5 – flexible 300/500 V cable with three 1.5 mm² copper cores including PE. The designation H05VVH2-F means a flat two-core design.

    Kibirkštis
    KibirkštisAnd what are OMY and OWY?
    Fazė
    FazėThese are older names still used on the market: OMY corresponds to H03VV-F (300/300 V), OWY to H05VV-F (300/500 V). Before buying, still check the number of cores, cross-section and rated voltage.

    How many cores: 2, 3, 4 or 5?

    2 cores – no PE
    L and N. Only for appliances that need no PE (protection class II).
    3G – L, N, PE
    The most common choice for earthed single-phase appliances.
    4G – extra circuit
    Three-phase without N or an extra control core, per the appliance diagram.
    5G – three-phase
    L1, L2, L3, N and PE when the appliance needs all five conductors.
    ⚠ Do not confuse: 3×1.5 and 3G1.5 are not always the same. G means the cable has a green-yellow protective core; × – that it does not. The green-yellow core is used only as PE, never as phase, neutral or control signal.

    Cross-section by current and power

    A cable cannot be chosen by power alone: you need the current, installation method, ambient temperature, number of loaded cores and length. First – the power-to-current ratio for a single-phase 230 V load with cos φ = 1.

    Appliance power Current at 230 V What to check
    100 W 0.43 A Appliance class, connection design
    500 W 2.17 A Core cross-section and flexibility
    1000 W 4.35 A Continuous load and temperature
    2000 W 8.70 A Cable current and connections
    3000 W 13.04 A Circuit protection and appliance manual
    3680 W 16.00 A Plug, socket and cable ratings
    Formula: P = U × I × cos φ. For heaters cos φ ≈ 1, so 230 V × 10 A ≈ 2300 W. For motors and pumps cos φ is usually 0.8–0.9, and the starting current is several times higher.

    Indicative continuous current and power

    Typical manufacturer values for flexible PVC cables (in free air, +30 °C ambient). This is a comparison table, not a basis for selecting protection.

    Cross-section Indicative current Power at 230 V (cos φ = 1)
    0.5 mm² ≈ 3 A ≈ 0.7 kW
    0.75 mm² ≈ 6 A ≈ 1.4 kW
    1 mm² ≈ 10 A ≈ 2.3 kW
    1.5 mm² ≈ 16 A ≈ 3.7 kW
    2.5 mm² ≈ 25 A ≈ 5.8 kW
    4 mm² ≈ 32 A ≈ 7.4 kW
    ⚠ Important: cables that are coiled, covered with thermal insulation or exposed to higher temperatures have a lower permissible current. Check exact values in the specific cable data sheet. The table does not replace an electrical design.

    Copper conductor resistance by cross-section

    Maximum DC resistance of class 5 copper conductors, +20 °C.

    Cross-section Resistance, Ω/km Typical use
    0.5 mm² 39,0 Low loads
    0.75 mm² 26,0 Light appliances
    1 mm² 19,5 Low and medium loads
    1.5 mm² 13,3 Medium loads
    2.5 mm² 7,98 Higher loads, longer lines
    4 mm² 4,95 Higher loads where terminals allow

    Length and voltage drop

    Part of the voltage “stays” in a long cable. The table shows the voltage drop of a single-phase 230 V circuit at 10 A (length from source to appliance one way, resistance at +20 °C). Indicative limit – 3 % (6.9 V); values above it are highlighted.

    Length 1 mm² 1.5 mm² 2.5 mm² 4 mm²
    5 m 1.95 V 1.33 V 0.80 V 0.49 V
    10 m 3.90 V 2.66 V 1.60 V 0.99 V
    20 m 7.80 V 5.32 V 3.19 V 1.98 V
    30 m 11.70 V 7.98 V 4.79 V 2.97 V
    Formula: ΔU ≈ 2 × L × I × R / 1000
    L – length (m), I – current (A), R – resistance (Ω/km). The factor 2 covers the phase and neutral cores.
    Example: 1 mm² cable, 20 m, 10 A → 7.8 V (≈ 3.4 %), with 1.5 mm² → 5.3 V (≈ 2.3 %).
    ⚠ Calculation limits: power factor, cable heating and joint resistance are not included. Voltage drop must be assessed for the whole circuit from the distribution board, not only the last connection cable.

    Construction and general data

    Product type Flexible copper connection cables H03VV-F and H05VV-F (OMY, OWY)
    Conductor Stranded annealed copper conductor, class 5 (EN 60228)
    Insulation and sheath PVC core insulation and PVC outer sheath
    Rated voltage H03VV-F – 300/300 V; H05VV-F – 300/500 V
    Maximum conductor temperature +70 °C under normal operating conditions
    Ambient temperature Installation −5…+40 °C, operation −30…+70 °C (Lietkabelis data)
    Bending radius ≥ 5 × cable diameter (Lietkabelis data)
    Main standard EN 50525-2-11
    Typical use Flexible connection of electrical appliances indoors
    Sales By the metre – we cut the required length; check the minimum quantity on the product page

    Damp rooms and outdoors

    Suitability of the cable and safety of the whole connection are not the same. Even if the cable suits a damp room, the plug, socket, box and appliance must have protection suited to the location.

    Environment Assessment Note
    Dry living room Suitable Choose by load.
    Kitchen, utility room Possible Water, heat and mechanical impact matter.
    Bathroom Only after assessing conditions Observe bathroom zones, IP and safety requirements.
    Short-term outdoor use Limited Protect from rain, UV and mechanical damage.
    Permanent outdoor, underground, open rain Not suitable Choose a cable made for the environment.
    Moving industrial equipment Usually not suitable A design made for dynamic loads is needed.
    ⚡ Electrical safety: a PVC sheath does not give a plug or joint IP44, IP65 or any other IP rating. In damp environments the whole installation is assessed. Do not use loose, unprotected joints where water can get in.

    H03VV-F, H05VV-F or another cable?

    Cable When to choose Limitation
    H03VV-F Light appliances indoors 300/300 V only, light duty
    H05VV-F Household appliances, medium duty, 230/400 V Not for permanent outdoor use and harsh conditions
    H05RR-F When a rubber-insulated flexible cable is needed Check the intended use in the manufacturer data
    H07RN-F Outdoor equipment, construction sites, harsher conditions Thicker and more expensive than PVC
    BVV-LL Flat cable for fixed installation Not for flexible connection
    NYM-J Permanent indoor installation Not to be laid directly in the ground
    CYKY-L Universal power cable: indoors, outdoors, underground with protection Not flexible for appliance connection
    H07V-K Single-core flexible wires for panel wiring No common sheath – only in conduit or enclosure

    ⚠ What to check before buying

    1. Cable type
    Is H03VV-F enough or is H05VV-F needed?
    2. Voltage
    230 V single-phase or 400 V three-phase connection?
    3. Current and cross-section
    What are the continuous and starting currents? Does the protection fit?
    4. PE need
    Does the appliance need a green-yellow protective core?
    5. Environment
    Will the cable face moisture, heat, UV or frost?
    6. Length and connections
    Are voltage drop, terminals, ferrules and strain relief OK?

    Common mistakes and their consequences

    ✗ Mistake Consequence / correct solution
    H03VV-F used for any 230 V appliance Mechanical strength too low. Check the current and appliance requirements.
    2-core cable instead of 3G for an earthed appliance No PE – risk of electric shock.
    Assuming 300/500 V suits any 500 V circuit Assess U0/U, the network system and the whole environment.
    Cable left outdoors permanently PVC ages from UV and frost, the sheath cracks.
    Stranded conductor clamped directly in a terminal Strands splay, the joint heats up. Use ferrules.
    Cable bent right at the plug or housing Cores get damaged. Provide strain relief and observe the bending radius.
    Long line with a thin cable High voltage drop, the appliance performs worse.

    ⚡ Safe connection – Fazė's advice

    Kibirkštis
    KibirkštisHow do I connect a flexible cable safely?
    Fazė
    FazėProtect it not only from overload but also from pulling out and core damage. Before connecting, check the appliance rated current, cable outer diameter, terminals, PE continuity and strain relief.
    • Before work disconnect the supply, secure it against reconnection and verify there is no voltage.
    • Before replacing an appliance's factory cable, read the manufacturer's requirements.
    • Use proper ferrules, terminals and strain relief; never use the green-yellow core for anything else.
    • A new connection should be tested (PE continuity, insulation resistance).
    • Mains circuits must be connected by an appropriately qualified electrician.

    Diagram: wrong / right

    ✗ WRONG
    230 V mains
    ↓
    H03VV-F 2×0.5
    ↓
    Class I washing machine

    A cable made for light mechanical stress, unchecked cross-section and no PE, which a class I appliance requires.

    ✓ RIGHT
    230 V mains with PE
    ↓
    H05VV-F 3G1.5*
    ↓
    Class I washing machine

    A cable for medium duty with PE; current, connection and appliance requirements assessed.

    * 3G1.5 – an illustrative example. A specific appliance may need a different cross-section or cable type.

    ⚠ The diagram is for guidance only. Before installation check it against the appliance and cable manufacturer instructions and applicable requirements. The qualified person performing the installation is responsible for it; UAB „Elektrotechnikos sprendimai“ is not liable for installation and possible errors.

    FAQ

    Asks Kibirkštis, answered by Fazė.

    Kibirkštis
    KibirkštisWhat is the difference between H03VV-F and H05VV-F?
    Fazė
    FazėH03VV-F – 300/300 V, for light mechanical stress. H05VV-F – 300/500 V, for medium loads and a wider range of appliances.
    Kibirkštis
    KibirkštisIs H03VV-F suitable for a washing machine?
    Fazė
    FazėUsually H05VV-F or the cable specified by the appliance manufacturer is chosen. H03VV-F is for light connections.
    Kibirkštis
    KibirkštisCan H05VV-F be used for a three-phase 400 V appliance?
    Fazė
    FazėYes, its voltage rating allows it, but the number of cores and cross-section must be chosen and the conditions assessed. H03VV-F is not suitable.
    Kibirkštis
    KibirkštisCan H05VV-F be used in a bathroom?
    Fazė
    FazėOnly following bathroom zones, IP protection and the appliance manufacturer's requirements. The whole connection matters, not just the cable.
    Kibirkštis
    KibirkštisAre these cables UV resistant?
    Fazė
    FazėNo. Standard PVC is not made for permanent sun and outdoor exposure.
    Kibirkštis
    KibirkštisWhat does 3G1.5 mean?
    Fazė
    FazėThree 1.5 mm² cores, one of them green-yellow PE.
    Kibirkštis
    KibirkštisCan 2×1.5 replace 3G1.5?
    Fazė
    FazėNo, if the appliance requires PE. A two-core cable has no protective core.
    Kibirkštis
    KibirkštisIs a larger cross-section always better?
    Fazė
    FazėLower resistance and voltage drop, but a thicker, less flexible cable that may not fit the appliance entry or terminals.
    Kibirkštis
    KibirkštisCan it be laid in walls instead of NYM-J?
    Fazė
    FazėNo. H03VV-F and H05VV-F are for connecting appliances; for fixed installation choose NYM-J or CYKY-L.
    Kibirkštis
    KibirkštisAre H05VV-F and OWY the same?
    Fazė
    FazėYes, OWY is the older name of H05VV-F (OMY – H03VV-F). Still check the number of cores and cross-section.
    Kibirkštis
    KibirkštisDo you sell by the metre?
    Fazė
    FazėYes, we cut the required length; check the minimum quantity on the product page. For larger quantities we prepare a quotation.

    Standards and important information

    • EN 50525-2-11 – flexible low-voltage cables with PVC insulation and sheath.
    • EN 60228 – conductors of insulated cables, including class 5 flexible copper conductors.
    • EN 50565-1 and EN 50565-2 – guidance on the use of cables.
    Important: outer diameters, bending radii, temperature limits and certificates may differ between manufacturers. Match the final choice with the specific cable data sheet and appliance requirements. Tables and formulas are indicative and do not replace a design or the assessment of a qualified specialist. UAB „Elektrotechnikos sprendimai“ is not liable for damage caused by an improperly selected cable or faulty installation, to the extent permitted by law.

    For installers and projects

    ✂ Exact length
    We cut the required length; the minimum quantity is shown on the product page.
    ■ Project quantities
    For larger quantities we prepare an individual quotation.
    ⚡ Complete set
    We will also select modular equipment and cable accessories.

    Not sure which cable to choose?

    Tell us the appliance power or current, supply voltage, length, number of cores and environment – we will help you choose H03VV-F, H05VV-F or another suitable cable.

    ☎ +370 658 01033✉ info@elsprendimai.euContacts
    Read more
    Flexible copper cable H03VV-F | 2×0.75 mm² | 300/300 V | round | white | 1 m | Lietkabelis
    Code: 91527501

    H03VV-F 2×0.75 mm² – AB Lietkabelis flexible round copper cable with class 5 conductors, PVC insulation and a white PVC sheath, 300/300 V. Sold by the metre.

    Cores: L and N, no PE. Indicative current ≈ 6 A – for light appliances indoors.

    Price 0.40 € VAT incl.
    ( 0.33 € VAT excl. )
    Flexible copper cable H03VV-F | 2×0.5 mm² | 300/300 V | round | white | 1 m | Lietkabelis
    Code: 91525001

    H03VV-F 2×0.5 mm² – AB Lietkabelis flexible round copper cable with class 5 conductors, PVC insulation and a white PVC sheath, 300/300 V. Sold by the metre.

    Cores: L and N, no PE. Indicative current ≈ 3 A – for light appliances indoors.

    Price 0.30 € VAT incl.
    ( 0.25 € VAT excl. )
    Flexible copper cable H03VV-F | 4G0.75 mm² | 300/300 V | round | black | 1 m | Lietkabelis
    Code: 91540702

    H03VV-F 4G0.75 mm² – AB Lietkabelis flexible round copper cable with class 5 conductors, PVC insulation and a black PVC sheath, 300/300 V. Sold by the metre.

    Cores: L, N, PE + additional (control) core. Indicative current ≈ 6 A – for light appliances indoors.

    Price 0.71 € VAT incl.
    ( 0.58 € VAT excl. )
    Flexible copper cable H03VV-F | 4G0.75 mm² | 300/300 V | round | white | 1 m | Lietkabelis
    Code: 91540701

    H03VV-F 4G0.75 mm² – AB Lietkabelis flexible round copper cable with class 5 conductors, PVC insulation and a white PVC sheath, 300/300 V. Sold by the metre.

    Cores: L, N, PE + additional (control) core. Indicative current ≈ 6 A – for light appliances indoors.

    Price 0.71 € VAT incl.
    ( 0.58 € VAT excl. )
    Flexible copper cable H03VV-F | 4G0.5 mm² | 300/300 V | round | black | 1 m | Lietkabelis
    Code: 91540502

    H03VV-F 4G0.5 mm² – AB Lietkabelis flexible round copper cable with class 5 conductors, PVC insulation and a black PVC sheath, 300/300 V. Sold by the metre.

    Cores: L, N, PE + additional (control) core. Indicative current ≈ 3 A – for light appliances indoors.

    Price 0.54 € VAT incl.
    ( 0.44 € VAT excl. )
    Flexible copper cable H03VV-F | 4G0.5 mm² | 300/300 V | round | white | 1 m | Lietkabelis
    Code: 91540501

    H03VV-F 4G0.5 mm² – AB Lietkabelis flexible round copper cable with class 5 conductors, PVC insulation and a white PVC sheath, 300/300 V. Sold by the metre.

    Cores: L, N, PE + additional (control) core. Indicative current ≈ 3 A – for light appliances indoors.

    Price 0.54 € VAT incl.
    ( 0.44 € VAT excl. )
    Flexible copper cable H05VV-F | 4G4 mm² | 300/500 V | round | white | 1 m | Lietkabelis
    Code: 92344001

    H05VV-F 4G4 mm² – AB Lietkabelis flexible round copper cable with class 5 conductors, PVC insulation and a white PVC sheath, 300/500 V. Sold by the metre.

    Cores: L1, L2, L3, PE or L, N, PE + control core. Indicative current ≈ 32 A – for three-phase and single-phase appliances indoors.

    Price 3.35 € VAT incl.
    ( 2.77 € VAT excl. )
    Flexible copper cable H05VV-F | 4G2.5 mm² | 300/500 V | round | white | 1 m | Lietkabelis
    Code: 92342501

    H05VV-F 4G2.5 mm² – AB Lietkabelis flexible round copper cable with class 5 conductors, PVC insulation and a white PVC sheath, 300/500 V. Sold by the metre.

    Cores: L1, L2, L3, PE or L, N, PE + control core. Indicative current ≈ 25 A – for three-phase and single-phase appliances indoors.

    Price 2.20 € VAT incl.
    ( 1.82 € VAT excl. )
    Flexible copper cable H05VV-F | 4G1.5 mm² | 300/500 V | round | white | 1 m | Lietkabelis
    Code: 92341501

    H05VV-F 4G1.5 mm² – AB Lietkabelis flexible round copper cable with class 5 conductors, PVC insulation and a white PVC sheath, 300/500 V. Sold by the metre.

    Cores: L1, L2, L3, PE or L, N, PE + control core. Indicative current ≈ 16 A – for three-phase and single-phase appliances indoors.

    Price 1.36 € VAT incl.
    ( 1.13 € VAT excl. )
    Flexible copper cable H05VV-F | 4G1 mm² | 300/500 V | round | black | 1 m | Lietkabelis
    Code: 92341002

    H05VV-F 4G1 mm² – AB Lietkabelis flexible round copper cable with class 5 conductors, PVC insulation and a black PVC sheath, 300/500 V. Sold by the metre.

    Cores: L1, L2, L3, PE or L, N, PE + control core. Indicative current ≈ 10 A – for three-phase and single-phase appliances indoors.

    Price 0.96 € VAT incl.
    ( 0.80 € VAT excl. )
    Flexible copper cable H05VV-F | 4G0.75 mm² | 300/500 V | round | white | 1 m | Lietkabelis
    Code: 92340701

    H05VV-F 4G0.75 mm² – AB Lietkabelis flexible round copper cable with class 5 conductors, PVC insulation and a white PVC sheath, 300/500 V. Sold by the metre.

    Cores: L1, L2, L3, PE or L, N, PE + control core. Indicative current ≈ 6 A – for three-phase and single-phase appliances indoors.

    Price 0.76 € VAT incl.
    ( 0.63 € VAT excl. )
    Flexible copper cable H05VV-F | 5G4 mm² | 300/500 V | round | white | 1 m | Lietkabelis
    Code: 92354001

    H05VV-F 5G4 mm² – AB Lietkabelis flexible round copper cable with class 5 conductors, PVC insulation and a white PVC sheath, 300/500 V. Sold by the metre.

    Cores: L1, L2, L3, N, PE. Indicative current ≈ 32 A – for three-phase and single-phase appliances indoors.

    Price 4.29 € VAT incl.
    ( 3.55 € VAT excl. )
    Flexible copper cable H05VV-F | 5G2.5 mm² | 300/500 V | round | white | 1 m | Lietkabelis
    Code: 92352501

    H05VV-F 5G2.5 mm² – AB Lietkabelis flexible round copper cable with class 5 conductors, PVC insulation and a white PVC sheath, 300/500 V. Sold by the metre.

    Cores: L1, L2, L3, N, PE. Indicative current ≈ 25 A – for three-phase and single-phase appliances indoors.

    Price 2.76 € VAT incl.
    ( 2.28 € VAT excl. )
    Flexible copper cable H05VV-F | 5G1.5 mm² | 300/500 V | round | white | 1 m | Lietkabelis
    Code: 92351501

    H05VV-F 5G1.5 mm² – AB Lietkabelis flexible round copper cable with class 5 conductors, PVC insulation and a white PVC sheath, 300/500 V. Sold by the metre.

    Cores: L1, L2, L3, N, PE. Indicative current ≈ 16 A – for three-phase and single-phase appliances indoors.

    Price 1.70 € VAT incl.
    ( 1.41 € VAT excl. )
    Flexible copper cable H05VV-F | 5G1 mm² | 300/500 V | round | white | 1 m | Lietkabelis
    Code: 92351001

    H05VV-F 5G1 mm² – AB Lietkabelis flexible round copper cable with class 5 conductors, PVC insulation and a white PVC sheath, 300/500 V. Sold by the metre.

    Cores: L1, L2, L3, N, PE. Indicative current ≈ 10 A – for three-phase and single-phase appliances indoors.

    Price 1.21 € VAT incl.
    ( 1.00 € VAT excl. )
    Flexible copper cable H05VV-F | 5G0.75 mm² | 300/500 V | round | white | 1 m | Lietkabelis
    Code: 92350701

    H05VV-F 5G0.75 mm² – AB Lietkabelis flexible round copper cable with class 5 conductors, PVC insulation and a white PVC sheath, 300/500 V. Sold by the metre.

    Cores: L1, L2, L3, N, PE. Indicative current ≈ 6 A – for three-phase and single-phase appliances indoors.

    Price 0.96 € VAT incl.
    ( 0.80 € VAT excl. )
    Flexible copper cable H05VV-F | 3G4 mm² | 300/500 V | round | white | 1 m | Lietkabelis
    Code: 92334001

    H05VV-F 3G4 mm² – AB Lietkabelis flexible round copper cable with class 5 conductors, PVC insulation and a white PVC sheath, 300/500 V. Sold by the metre.

    Cores: L, N, PE. Indicative current ≈ 32 A – for household appliances indoors.

    Price 2.57 € VAT incl.
    ( 2.12 € VAT excl. )
    Flexible copper cable H05VV-F | 3G2.5 mm² | 300/500 V | round | white | 1 m | Lietkabelis
    Code: 92332501

    H05VV-F 3G2.5 mm² – AB Lietkabelis flexible round copper cable with class 5 conductors, PVC insulation and a white PVC sheath, 300/500 V. Sold by the metre.

    Cores: L, N, PE. Indicative current ≈ 25 A – for household appliances indoors.

    Price 1.68 € VAT incl.
    ( 1.39 € VAT excl. )
    Flexible copper cable H05VV-F | 3G1.5 mm² | 300/500 V | round | white | 1 m | Lietkabelis
    Code: 92331501

    H05VV-F 3G1.5 mm² – AB Lietkabelis flexible round copper cable with class 5 conductors, PVC insulation and a white PVC sheath, 300/500 V. Sold by the metre.

    Cores: L, N, PE. Indicative current ≈ 16 A – for household appliances indoors.

    Price 1.04 € VAT incl.
    ( 0.86 € VAT excl. )
    Flexible copper cable H05VV-F | 3G1 mm² | 300/500 V | round | white | 1 m | Lietkabelis
    Code: 92331001

    H05VV-F 3G1 mm² – AB Lietkabelis flexible round copper cable with class 5 conductors, PVC insulation and a white PVC sheath, 300/500 V. Sold by the metre.

    Cores: L, N, PE. Indicative current ≈ 10 A – for household appliances indoors.

    Price 0.73 € VAT incl.
    ( 0.60 € VAT excl. )
    Flexible copper cable H05VV-F | 3G0.75 mm² | 300/500 V | round | white | 1 m | Lietkabelis
    Code: 92330701

    H05VV-F 3G0.75 mm² – AB Lietkabelis flexible round copper cable with class 5 conductors, PVC insulation and a white PVC sheath, 300/500 V. Sold by the metre.

    Cores: L, N, PE. Indicative current ≈ 6 A – for household appliances indoors.

    Price 0.59 € VAT incl.
    ( 0.48 € VAT excl. )
    Flexible copper cable H05VV-F | 2×4 mm² | 300/500 V | round | white | 1 m | Lietkabelis
    Code: 92324001

    H05VV-F 2×4 mm² – AB Lietkabelis flexible round copper cable with class 5 conductors, PVC insulation and a white PVC sheath, 300/500 V. Sold by the metre.

    Cores: L and N, no PE. Indicative current ≈ 32 A – for household appliances indoors.

    Price 1.86 € VAT incl.
    ( 1.53 € VAT excl. )
    Flexible copper cable H05VV-F | 2×1 mm² | 300/500 V | round | white | 1 m | Lietkabelis
    Code: 92321001

    H05VV-F 2×1 mm² – AB Lietkabelis flexible round copper cable with class 5 conductors, PVC insulation and a white PVC sheath, 300/500 V. Sold by the metre.

    Cores: L and N, no PE. Indicative current ≈ 10 A – for household appliances indoors.

    Price 0.53 € VAT incl.
    ( 0.44 € VAT excl. )
    Flexible copper cable H05VV-F | 2×0.75 mm² | 300/500 V | round | white | 1 m | Lietkabelis
    Code: 92320701

    H05VV-F 2×0.75 mm² – AB Lietkabelis flexible round copper cable with class 5 conductors, PVC insulation and a white PVC sheath, 300/500 V. Sold by the metre.

    Cores: L and N, no PE. Indicative current ≈ 6 A – for household appliances indoors.

    Price 0.44 € VAT incl.
    ( 0.36 € VAT excl. )