  • Backup automatic power switch for generators | for uninterrupted power supply | 4P | 630A | 400/415V

    Code: ES-NXZ-630/4P
    Price 1250.60 € VAT incl.
    ( 1033.55 € VAT excl. )
    Buy more, pay less
    10+ pcs.  – 1212.42 € for pcs. -3%
    Want another price? Suggest yours!

    Automatic Transfer Switch ATS 630A – a 4-pole, three-phase 400/415V AC device designed for automatic transfer between two power sources. Suitable for mains–mains and mains–generator systems, it monitors phase loss, undervoltage and overvoltage, supports both automatic and manual control, and provides adjustable transfer delays. The L1, L2, L3 and N conductors are switched. 

  • Automatic transfer switch ATS | 4P | 630A | 400/415V AC

    Automatic transfer switch ATS designed for three-phase four-wire electrical systems with two independent power sources. The device automatically monitors the condition of the main and backup power supplies and, if the main source fails or its voltage moves outside the configured limits, can transfer the load to the backup source.

    This version is 4P, 630A, 400/415V AC. The four-pole construction is intended for a three-phase four-wire system, therefore L1, L2, L3 and N conductors are switched during transfer. The ATS can be used in mains–mains or mains–generator backup power systems.

    Automatic transfer between two power sources

    The controller monitors the voltage of the main and backup sources. If phase failure, loss of voltage, undervoltage or overvoltage is detected, the ATS can transfer the load to another suitable source after the configured delay. When the main supply is restored, automatic return or operation without automatic return can be selected.

    630A
    Rated current
    4P
    L1 + L2 + L3 + N
    400/415V
    50Hz
    AC-33B
    Utilization category

    Operating principle

    The ATS has two main power positions: Normal – main power source and Alternative – backup power source. An OFF position is also provided, in which the load is disconnected from both sources.

    Situation ATS operation
    Main source is normal The load is supplied from the main source.
    Phase or voltage is lost After the configured transfer delay, the backup source is checked and connected if suitable.
    Undervoltage When voltage falls below the configured threshold, the source is considered unsuitable.
    Overvoltage When voltage exceeds the configured threshold, the ATS can transfer the load to the backup source.
    Main source is restored Depending on the configured mode, the ATS can automatically return the load to the main source after the return delay.
    Manual mode The operator can manually select the main source, backup source or OFF position.

    4P construction – three phases and neutral

    The ATS is designed for a three-phase four-wire 400/415V AC system. The four-pole construction allows switching of:

    • L1 – first phase
    • L2 – second phase
    • L3 – third phase
    • N – neutral conductor
    PE conductor is not switched

    4P switching includes the three phase conductors and neutral conductor. The protective PE conductor is not part of the ATS switching circuit and must be connected according to the design of the specific electrical system.

    Mains–mains and mains–generator

    The controller supports different backup power configurations. Two independent mains supplies can be used, or a main electrical supply together with a backup generator.

    Mains → mains

    Transfer between two independent mains supply inputs. Automatic transfer with automatic return or without automatic return is possible.

    Mains → generator

    If the main supply fails, the ATS can activate the generator start control and, once the generator reaches suitable operating parameters, transfer the load.

    Automatic generator start control

    The Type A controller includes a generator control function. Generator start and stop delays can be programmed.

    Typical operating sequence

    Main supply fails → ATS detects the fault → generator start signal is issued → generator voltage is checked after the configured delay → load is transferred to the backup generator.

    Adjustable voltage thresholds

    Parameter Default value Adjustment range
    Undervoltage transfer threshold 187V 160-200V
    Overvoltage transfer threshold 263V 240-290V
    Transfer delay 5s 0-300s
    Return delay 5s 0-300s
    Generator start delay 5s 0-300s
    Generator stop delay 5s 0-300s
    Voltage thresholds are specified for 230V phase monitoring

    Although the main ATS system is three-phase 400/415V, the controller instructions specify undervoltage and overvoltage thresholds in the 160–290V range. This corresponds to monitoring individual 230V phase voltages relative to neutral.

    Type A controller

    The standard Type A controller includes automatic and manual operating modes, main and backup source monitoring, adjustable delays, generator control, fire-fighting system control interface and LED display.

    Function Type A controller
    Automatic / manual switching Yes
    Main position Yes
    Backup position Yes
    OFF position Yes
    Phase failure monitoring Yes
    Undervoltage monitoring Yes
    Overvoltage monitoring Yes
    Automatic transfer and return Yes
    Automatic transfer without automatic return Yes
    Mains–mains Yes
    Mains–generator Yes
    Generator control Yes
    Fire-fighting system control interface Yes
    Display LED

    Control panel

    The front of the controller separately displays the status and voltage parameters of the main and backup power sources. The buttons allow selection of automatic or manual mode, parameter adjustment and manual source transfer.

    Control / indication Function
    Automatic / Manual Indication and selection of automatic or manual mode.
    Setting Parameter setting mode.
    Generator startup Generator start signal indication.
    Fire-fighting startup Indication of fire-fighting control function activation.
    Normal Main supply voltage and status display.
    Alternative Backup supply voltage and status display.
    OFF Switches the ATS to the disconnected position in manual mode.
    + / − Increase or decrease setting values.

    Short-circuit characteristics

    100kA
    Iq conditional short-circuit current
    50kA
    Icm short-circuit making capacity
    25kA / 0.2s
    Icw short-time withstand current
    ATS does not replace a protective circuit breaker

    The specified Iq, Icm and Icw characteristics describe the switching device's capability to operate under short-circuit conditions with appropriate protection coordination. The ATS must be used together with correctly selected circuit breakers or fuses.

    Transfer time

    Contact transfer time 1.5s x (1 ±50%)
    Total operating transfer time 3.3s x (1 ±10%)
    Programmable transfer delay 0-300s

    Transfer delay is not the same as the mechanical contact transfer time. The delay determines how long the controller waits before starting the transfer process, while the contact transfer time describes the operation of the ATS mechanism itself.

    Standards and compliance

    Transfer equipment standards IEC 60947-1, IEC 60947-6-1
    Low-temperature test IEC 60068-2-1
    High-temperature test IEC 60068-2-2
    Humidity test IEC 60068-2-30
    Salt mist test IEC 60068-2-11
    Certification CB, CE, KEMA

    Technical specifications

    Product type Automatic transfer switch ATS
    Number of power sources 2
    Electrical system Three-phase, four-wire
    Number of poles 4P
    Rated current 630A
    Rated operational voltage Ue 400/415V AC, 50Hz
    Rated insulation voltage Ui 800V AC
    Rated impulse withstand voltage Uimp 8kV
    Utilization category AC-33B
    Conditional short-circuit current Iq 100kA
    Short-circuit making capacity Icm 50kA
    Short-time withstand current Icw 25kA / 0.2s
    Contact transfer time s x (1 ±50%)
    Operating transfer time 3.3s x (1 ±10%)
    Mechanical service life 3000 cycles
    Electrical service life 1000 cycles
    Controller type Type A, standard
    Controller mounting Integrated / separate
    Controller supply voltage Us 230/240V AC, 50/60Hz
    Control voltage range 85%–110% Ue
    Transfer delay 0-300s
    Return delay 0-300s
    Pollution degree 3
    Main circuit installation category IV
    Auxiliary circuit installation category III
    Controller installation category II
    Utilization category AC-33B
    Maximum installation altitude Up to 2000m without additional derating assessment
    Dimensions 430x272x230mm

    Advantages

    • 630A rated current for three-phase backup power systems.
    • 4P construction switches three phases and neutral.
    • 400/415V AC for three-phase four-wire systems.
    • AC-33B utilization category intended for switching equipment capable of controlling mixed and motor loads under the corresponding utilization conditions.
    • Mains–mains and mains–generator operating modes.
    • Automatic and manual switching.
    • Adjustable undervoltage and overvoltage thresholds.
    • Adjustable 0–300s transfer and return delay.
    • Generator start and stop control.
    • OFF position allows the load to be disconnected from both sources.
    • Phase failure monitoring.
    • Fire-fighting system control interface.
    • LED display for monitoring the main and backup source status.
    • High short-circuit ratings: Iq 100kA, Icm 50kA, Icw 25kA / 0.2s.

    Disadvantages / limitations

    • Not intended for parallel operation of sources: only one source supplies the load at a time.
    • Not a source synchronisation device.
    • ATS does not replace short-circuit protection: appropriate circuit breaker or fuse coordination is required.
    • Neutral and PE arrangement must be designed according to the specific electrical system and generator earthing arrangement.

    Suitable for

    • Transfer between the main electrical supply and generator
    • Transfer between two independent mains supply inputs
    • Industrial electrical systems
    • Commercial buildings
    • Apartment and residential buildings
    • Manufacturing and warehousing facilities
    • Pump stations and technical systems
    • Facilities requiring automatic backup power transfer

    Not suitable for

    • Systems requiring completely uninterrupted UPS power
    • Parallel operation of different AC sources
    • Synchronisation of generator and mains phases
    • Rated loads above 630A
    • Use as a replacement for a circuit breaker or fuse

    Practical application example

    In a commercial or industrial facility, the main 400/415V three-phase grid is used as the normal power source and a three-phase generator as the backup source. The ATS continuously monitors the phases and voltage of the main supply. If a phase is lost or the voltage falls below the configured threshold, a generator start signal is issued after the configured delay. Once the generator voltage stabilises, the ATS transfers L1, L2, L3 and N to the backup source. When the main supply is restored, the load can automatically return to the main source after the configured return delay.

    Frequently asked questions (FAQ)

    What is the rated current of the ATS?

    630A.

    What is the operating voltage?

    400/415V AC, 50Hz for a three-phase four-wire system.

    What does 4P mean?

    Four conductors are switched – L1, L2, L3 and N.

    Can the ATS be used with a generator?

    Yes. The controller supports mains–generator operation and includes generator start control.

    Can it be used with two mains supply inputs?

    Yes. Mains–mains operating mode is supported.

    Does the ATS automatically return to the main supply?

    It can. Automatic transfer with automatic return or automatic transfer without automatic return is supported.

    Can the transfer delay be adjusted?

    Yes. Transfer and return delays are adjustable from 0 to 300s.

    Is phase failure monitored?

    Yes. Phase failure / voltage loss monitoring is provided for both the main and backup sources.

    Does it provide undervoltage and overvoltage monitoring?

    Yes. According to the controller instructions, the undervoltage threshold is adjustable from 160–200V and the overvoltage threshold from 240–290V.

    Can it be switched manually?

    Yes. Automatic and manual control modes are available.

    Is there an OFF position?

    Yes. In manual mode, the disconnected OFF position can be selected.

    What is the insulation voltage?

    The rated insulation voltage Ui is 800V AC.

    What is the impulse withstand voltage?

    Uimp – 8kV.

    What is the utilization category?

    AC-33B.

    Important electrical safety and design note

    The 630A 4P ATS must be selected and connected according to the design of the specific electrical installation. Cable cross-sections, prospective short-circuit current, circuit breaker or fuse coordination, neutral and PE arrangement, generator earthing and control logic must be evaluated. The ATS is not intended for parallel connection of two AC power sources and does not replace short-circuit protection devices.

    Automatic transfer switch ATS 630A – 4P three-phase 400/415V AC automatic transfer device for two independent electrical power sources. Supports mains–mains and mains–generator configurations, automatic and manual control, phase failure, undervoltage and overvoltage monitoring, adjustable transfer and return delays and generator start control. Rated current 630A, Ui 800V AC, Uimp 8kV, utilization category AC-33B, Iq 100kA, Icm 50kA, Icw 25kA / 0.2s.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.