Products catalog

  • Blanking cover plate for cable entry | for 216×84 mm cut-out | no entries | grey | IP65 | HT Hi Tech Polymers | HTC-0

    Code: Sandariklis HTC-0

    HTC-0 is a blanking plate without entries that seals an unused standard 216 × 84 mm cut-out in a panel or enclosure wall. It is fixed in the same way as the HTC plates with entries, so it can later be replaced by a plate with entries. IP65, −40…+130 °C.

  • Blanking cover plate for cable entry | for 216×84 mm cut-out | no entries | grey | IP65 | HT Hi Tech Polymers | HTC-0

    HTC-0 is a blanking plate without entries for the standard 216 × 84 mm (C-hole) cut-out. It closes a cut-out that is not yet used, or no longer used, for cables and keeps the enclosure sealed to IP65. It is fixed through the same Ø10 mm holes (spacing 193 / 62 mm) as the HTC plates with entries.

    Key point:
    Panels are often built with several identical cut-outs for the future, and not all of them are needed straight away. HTC-0 closes such a cut-out neatly and tightly, and when cables are needed you simply replace it with a plate with entries – without modifying the enclosure.
    Entries
    0 (blank)
    Protection
    IP65
    Cut-out
    216 × 84 mm
    Temperature
    −40…+130 °C

    How it works

    Installation: the plate is placed over the 216 × 84 mm cut-out and screwed through Ø10 mm holes (spacing 193 / 62 mm).

    Operation: the solid TPE plate, pressed against the enclosure, covers the entire cut-out tightly.

    Result: the unused cut-out is closed to IP65 and ready for a future cable entry.

    Why choose HTC-0?
    HTC-0 lets you prepare panels and enclosures in the same way – with standard 216 × 84 mm cut-outs – and decide on the cable entry later. Until cables arrive, the cut-out is closed neatly and tightly, without improvised covers or silicone.

    Technical specifications

    Product type Blanking cover plate for cable entry
    Code HTC-0
    Manufacturer HT Hi Tech Polymers Oy (Finland)
    Openings and cable Ø none (blanking plate)
    Max. number of cables 0
    Enclosure cut-out 216 × 84 mm (C-hole, FL21)
    Fixing holes Ø10 mm, spacing 193 / 62 mm
    Degree of protection IP65 (EN 60529)
    Operating temperature −40…+130 °C
    Material TPE-SEBS, 50 ShA, halogen-free
    Properties resistant to oil splashes; for indoor and outdoor use
    Colour grey (RAL7035)

    Main functions

    • Closes a 216 × 84 mm cut-out – when no cables pass through it
    • IP65 – dust-tight and protected against water jets
    • Same fixing as HTC plates – Ø10 mm, 193 / 62 mm
    • Replaceable – later swapped for a plate with entries
    • Halogen-free TPE-SEBS – −40…+130 °C, resistant to oil splashes
    • Indoor and outdoor – according to the manufacturer

    Where is it used?

    • Panels and cabinets with spare 216 × 84 mm cut-outs
    • Series-produced enclosures where not all cut-outs are used
    • Construction phase, before cables are brought in
    • Panel refurbishment when some cables are removed
    • Outdoor cabinets where an unused cut-out must stay sealed
    • Temporary replacement of a damaged or unsuitable entry plate

    Use by need

    For panel manufacturers.
    Build identical enclosures with standard cut-outs and close the unused ones until the customer decides on the cabling.
    For installation electricians.
    An unused cut-out on site is closed in minutes with the same screws as the other HTC plates.
    For facility managers.
    The panel keeps a ready, tightly closed entry for future cables.

    Practical use

    If a distribution board has two 216 × 84 mm cut-outs but cables currently enter through only one, close the second with HTC-0; when new lines are needed, replace it with a plate with entries, e.g. HTC-25 or HTC-35.

    Pros

    • Seals an unused cut-out – IP65
    • Same fixing as the HTC plates with entries
    • Allows identical enclosures with spare cut-outs
    • Easily replaced when a cable entry is needed
    • −40…+130 °C, halogen-free, indoor and outdoor

    Cons / limitations

    • Not intended for cable entry – for that choose a plate with entries (e.g. HTC-50, HTC-35, HTC-25)
    • Fits only the 216 × 84 mm (C-hole) cut-out; for a 138 × 48 mm cut-out there is HTB-10
    • Not a fire barrier

    Safety and installation notes

    • Install the plate with the panel de-energised – screws or tools must not reach live parts.
    • Before fitting, check that the cut-out edges are deburred and no swarf is left in the panel.
    • The sealing surface must be flat and clean – otherwise IP65 is not maintained.
    • Tighten the screws evenly so the plate seats along its whole perimeter.

    Quick selection guide

    No entries
    For 216 × 84 mm cut-out
    Fixing Ø10 mm, 193 / 62 mm
    IP65
    Suitable when you need:
    • to seal an unused 216 × 84 mm cut-out
    • to keep a reserve for a future cable entry
    • to prepare several panels or enclosures identically
    Check before use:
    • that the cut-out really is 216 × 84 mm (C-hole)
    • that fixing holes are Ø10 mm, spacing 193 / 62 mm
    • that the sealing surface is flat and clean
    Important reminder: HTC-0 only closes the cut-out – cable entry requires a plate with entries, and fire-rated walls require dedicated fire-stopping systems.

    FAQ

    What is a blanking plate for?
    To seal an unused 216 × 84 mm cut-out and keep it in reserve.
    Can a cable be passed through HTC-0?
    No, it is a blanking plate; for cables choose a plate with entries for the same cut-out, e.g. HTC-25 or HTC-35.
    Is the fixing the same as other HTC plates?
    Yes, Ø10 mm holes, spacing 193 / 62 mm, the same 216 × 84 mm cut-out.
    What is the degree of protection of HTC-0?
    The manufacturer specifies IP65.
    Is it suitable for outdoor cabinets?
    Yes, the manufacturer specifies indoor and outdoor use, −40…+130 °C.
    Does it fit a 138 × 48 mm cut-out?
    No, HTC-0 is only for the 216 × 84 mm cut-out.

    Manufacturer documents

    Links open on external websites. Checked 2026-10-04. If data differ, the latest manufacturer edition applies – or contact us.

    HTC-0 blanking plate for 216 × 84 mm cut-out

    HTC-0 is an IP65 blanking plate without entries that seals an unused 216 × 84 mm cut-out and can later be replaced by a plate with entries.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

  • Subscribtion to new arrivals

    privacy policy

    Information