Membrane cable entry plate | for 216×84 mm cut-out | 1× Ø20–26 + 4× Ø14–20 + 16× Ø8–14 + 4× Ø5–7 mm | grey | IP65 | HT | HTC-25
Code: Sandariklis HTC-25HTC-25 is a membrane cable entry plate for a 216 × 84 mm cut-out with 25 entries: Ø20–26 mm for the feeder, 4 × Ø14–20 mm, 16 × Ø8–14 mm and 4 × Ø5–7 mm. The larger entries have an inner ring for a thinner cable (then IP55). IP65, −40…+130 °C.
-
Membrane cable entry plate | for 216×84 mm cut-out | 1× Ø20–26 + 4× Ø14–20 + 16× Ø8–14 + 4× Ø5–7 mm | grey | IP65 | HT | HTC-25
HTC-25 is a membrane cable entry plate for the standard 216 × 84 mm (C-hole) cut-out with 25 entries arranged for a small distribution board. Its special feature is the two-stage larger entries: the outer membrane ring seals a thicker cable (IP65), while the inner ring lets the same entry take a thinner cable (IP55).
Key point:
In a house or small-premises board the actual cable sizes are often known only on site. HTC-25 has margin for that: one entry can serve two cable ranges, so the plate adapts more easily to the real cable set. Sixteen medium entries cover a usual number of circuits, and four small Ø5–7 mm entries take thin control or communication lines.Entries
25Feeder
Ø20–26 mmProtection
IP65 / IP55Cut-out
216 × 84 mmHow it works
Installation: the plate is placed in a 216 × 84 mm cut-out and screwed through Ø10 mm holes (spacing 193 / 62 mm).
Operation: for a thicker cable the outer membrane ring is opened, for a thinner one only the inner ring; the opening is always made slightly smaller than the cable outer Ø.
Result: up to 25 cables through one cut-out – IP65 in the outer ranges and IP55 in the inner-ring ranges.
Why choose HTC-25?
The two-stage entries are the practical advantage of HTC-25: if a Ø8 mm cable arrives on site instead of the planned Ø18 mm one, the same entry still takes it through the inner ring. This reduces the risk that the plate will not suit the actual cable set.Technical specifications
Product type Membrane cable entry plate (two-stage entries) Code HTC-25 Manufacturer HT Hi Tech Polymers Oy (Finland) Openings and cable Ø 1 × Ø20–26 mm (IP55: Ø12–15 mm); 4 × Ø14–20 mm (IP55: Ø5–10 mm); 16 × Ø8–14 mm (IP55: Ø7–10 mm); 4 × Ø5–7 mm Max. number of cables 25 Enclosure cut-out 216 × 84 mm (C-hole, FL21) Fixing holes Ø10 mm, spacing 193 / 62 mm Degree of protection IP65 (inner-ring ranges – IP55) Operating temperature −40…+130 °C Material TPE-SEBS, 50 ShA, halogen-free Properties resistant to oil splashes; for indoor and outdoor use Colour grey (RAL7035) Main functions
- 1 entry Ø20–26 mm – for the feeder cable (inner ring Ø12–15 mm)
- 4 entries Ø14–20 mm – for larger circuits or sub-feeds (inner ring Ø5–10 mm)
- 16 entries Ø8–14 mm – for standard circuit cables (inner ring Ø7–10 mm)
- 4 entries Ø5–7 mm – for thin control, communication or sensor lines
- Two-stage membranes – one entry for two cable ranges
- IP65 in the outer ranges, −40…+130 °C
Where is it used?
- Distribution boards in houses and apartments
- Sub-distribution boards in offices and shops
- Panels in small workshops and production premises
- Heat pump and boiler room panels
- Panels in outbuildings, garages and warehouses
- Outdoor distribution cabinets next to buildings
- Panel refurbishment when an old cable entry is replaced
Use by need
For installation electricians.
Two-stage entries let you adapt to a cable that turned out thinner on site than planned.For small panel builders.
One plate with 25 entries matches the typical cable set of a small distribution board.For homeowners and facility managers.
A tidy, sealed panel bottom and free entries for future circuits – e.g. a new appliance or building.Practical use
If a house board has a Ø22 mm feeder, a few larger cables run to a heat pump and an outbuilding, and the remaining 12–14 circuits use standard cables, HTC-25 has entries for all of them, and the four small entries are left for thermostat or communication lines.Pros
- 25 entries in four sizes – from Ø5 to Ø26 mm
- Two-stage entries – one entry for two cable ranges
- IP65 in the outer ranges
- Matches the typical cable set of a small distribution board
- −40…+130 °C, halogen-free, indoor and outdoor
Cons / limitations
- When the inner-ring range is used, sealing is only IP55
- The feeder entry takes up to Ø26 mm – for a thicker feeder choose HTC-35 (up to Ø32 mm) or HTC-3
- The membrane does not provide strain relief – secure cables inside the panel
- Not a fire barrier
Safety and installation notes
- Work in the panel only after isolating it and verifying that it is dead.
- After making the cut-out, remove burrs and metal swarf.
- Measure the cable outer Ø before cutting and decide which ring to open – outer or inner.
- Do not open the outer ring for a thin cable – an oversized opening will not seal.
- Secure cables inside the panel so that pulling forces do not act on the membrane.
Quick selection guide
1 × Ø20–26 mm4 × Ø14–20 mm16 × Ø8–14 mm4 × Ø5–7 mmSuitable when you need:- up to 25 cables sealed into a small distribution board
- flexibility when actual cable Ø differ from the plan
- IP65 sealing in the standard ranges
Check before use:- the cable outer Ø and which ring will need to be opened
- whether IP55 in the inner-ring ranges is enough for your environment
- whether the enclosure has a 216 × 84 mm cut-out
Important reminder: HTC-25 seals the cable entry, but it does not take cable tension and is not a fire barrier – secure cables inside and use dedicated systems in fire-rated walls.FAQ
What do two ranges in one entry mean?
The outer ring is for a thicker cable (IP65), the inner ring for a thinner one (IP55).What feeder cable size fits?
The feeder entry takes a Ø20–26 mm cable or, via the inner ring, Ø12–15 mm.How many circuit cables can be installed?
16 entries Ø8–14 mm and 4 entries Ø14–20 mm – up to 25 cables in total including the feeder and small entries.How does HTC-25 differ from HTKC-25?
These are products of different construction: the manufacturer describes HTKC-25 as a diaphragm (membrane) inlet flange and HTC-25 as an inlet flange. The 216×84 mm cut-out, fixing and cable ranges are the same, so one can replace the other when mounting.Do unopened entries stay sealed?
Yes, unopened membranes stay closed.Is it suitable for an outdoor cabinet?
Yes, the manufacturer specifies indoor and outdoor use, −40…+130 °C.Manufacturer documents
Links open on external websites. Checked 2026-10-04. If data differ, the latest manufacturer edition applies – or contact us.
HTC-25 plate with two-stage entries
HTC-25 is an IP65 membrane cable entry plate for a 216 × 84 mm cut-out with 25 entries Ø5–26 mm and two-stage membranes for thinner cables.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
CYKY 5x4 | Copper power cable | CYKY-L 5G4 | 1m | blackCode: 91950413Price 3.68 € VAT incl.( 3.04 € VAT excl. )