Membrane cable entry plate with cones | for 216×84 mm cut-out | 25 cables Ø5–26 mm | grey | IP65 / IP55 | HT Hi Tech Polymers | HTKC-25
Code: Sandariklis HTKC-25HTKC-25 is a membrane cable entry plate with cones for a 216×84 mm cut-out, for up to 25 cables from Ø5 to Ø26 mm. The main ranges seal to IP65, and the larger cones also have an inner range for thinner cables at IP55.
-
Membrane cable entry plate with cones | for 216×84 mm cut-out | 25 cables Ø5–26 mm | grey | IP65 / IP55 | HT Hi Tech Polymers | HTKC-25
HTKC-25 is a TPE-SEBS elastomer plate for a 216×84 mm cut-out with 25 cones: one Ø20–26 mm, four Ø14–20 mm, sixteen Ø8–14 mm and four Ø5–7 mm. The larger cones are two-zone: the outer range seals to IP65, while the inner range accepts a much thinner cable (IP55).
Key point:
When cable diameters are not exactly known in advance – for example when refurbishing an old board – two-zone cones give a margin: the same cone takes both a thick and a thinner cable. The entry layout is the same as HTC-25, so these plates are interchangeable.Cables
up to 25Cable Ø
5–26 mmCut-out
216×84 mmProtection
IP65 / IP55How it works
A 216×84 mm cut-out and Ø10 mm fixing holes (spacing 193 × 62 mm) are made in the enclosure and the plate is screwed to the wall.
The cone is cut to the cable's outer diameter: at the outer step for the main range (IP65), at the inner ring for a thinner cable (IP55).
Each cable is sealed in its own cone; unused cones stay closed as reserve.
Why choose HTKC-25?
One plate covers a wide cable range from Ø5 to Ø26 mm, and the two-zone cones let you adapt flexibly to the actual cable diameters on site.Technical specifications
Product type Membrane cable entry plate with cones Code HTKC-25 Manufacturer HT Hi Tech Polymers Oy (Finland) Entries and cable Ø (IP65) 1 × Ø20–26 mm; 4 × Ø14–20 mm; 16 × Ø8–14 mm; 4 × Ø5–7 mm Inner range (IP55) Ø20–26 cone: Ø12–15 mm; Ø14–20 cones: Ø5–10 mm; Ø8–14 cones: Ø7–10 mm Max. number of cables 25 Enclosure cut-out 216 × 84 mm (C-shape, FL21) Fixing holes Ø10 mm, spacing 193 × 62 mm Degree of protection IP65; IP55 in the inner range (EN 60529) Operating temperature −40…+130 °C Material TPE-SEBS 50 ShA, halogen-free, oil-splash-resistant Colour grey (RAL 7035) Use indoor and outdoor Main functions
- Two-zone cones – the same cone suits a thicker (IP65) and a thinner (IP55) cable
- 1 cone Ø20–26 mm – for the board supply cable
- 4 cones Ø14–20 mm – for sub-feeder or larger load cables
- 16 cones Ø8–14 mm – for circuit cables
- 4 cones Ø5–7 mm – for thin control or communication cables
Where is it used?
- Refurbishment of old boards with mixed cable diameters
- Main boards in houses and terraced homes
- Distribution boards in small commercial premises
- Boards in outbuildings and garages
- Outdoor cabinets next to buildings
- Temporary and construction site boards
Use by need
For refurbishment electricians.
Two-zone cones allow existing, previously unmeasured cables to be sealed without extra glands.For panel assemblers.
The universal layout suits most small distribution boards, and HTKC-25 and HTC-25 are interchangeable.For facility managers.
When a cable is replaced with one of a different diameter, the inner range of the same cone is often enough.Practical application
If a refurbished house board keeps an old Ø24 mm supply cable and gets 3 new Ø16–18 mm cables for a heat pump and cooker, 14 circuit cables Ø9–12 mm and 2 thin Ø6 mm communication cables, HTKC-25 takes them all at IP65 and the remaining cones stay in reserve.Pros
- Wide cable range – Ø5–26 mm
- Two-zone cones – flexibility during installation
- Interchangeable with HTC-25 (same layout)
- Operating temperature −40…+130 °C
- Halogen-free material for indoor and outdoor use
Cons / limitations
- In the inner range sealing is only IP55 – where IP65 is required, the cable must match the outer range
- Only one cone above Ø20 mm; for several thick cables use HTKC-28
- For many thin cables HTKC-50 is a better fit
- Does not provide strain relief and is not a fire barrier
Safety and installation notes
- Work in the board with the power off and absence of voltage verified.
- Remove swarf after making the cut-out.
- Decide which range you will use before cutting – a cone cut too deep will no longer seal the outer range.
- Secure cables inside the board.
Quick selection guide
Cut-out 216×84 mmØ5–26 mm, up to 25 cablesTwo-zone conesIP65 / IP55, −40…+130 °CSuitable when you need:- cables of various sizes into a small board
- flexibility when cable diameters are not known in advance
- an equivalent replacement for HTC-25
Check before use:- which cables fall into the main (IP65) and which into the inner (IP55) range
- whether IP65 is required for the whole entry
- that there is no more than one thick cable (above Ø20 mm)
Important reminder: The inner cone range provides only IP55 – where the board needs IP65, choose cables to the outer range; the plate is not a fire-stop seal.FAQ
What do the double ranges, e.g. Ø20–26 / Ø12–15 mm, mean?
The larger range seals to IP65, the smaller inner ring takes a thinner cable at IP55.Are HTKC-25 and HTC-25 the same?
No – these are products of different construction: the manufacturer describes HTKC-25 as a diaphragm (membrane) inlet flange and HTC-25 as an inlet flange. The 216×84 mm cut-out, fixing and cable ranges are the same, so one can replace the other when mounting.How many cables fit?
Up to 25: 1 × Ø20–26, 4 × Ø14–20, 16 × Ø8–14 and 4 × Ø5–7 mm.Is it suitable outdoors?
Yes, the material is intended for indoor and outdoor use, operating temperature −40…+130 °C.What if a cone has been cut too deep?
Use it for a thicker cable or replace the plate – an oversize opening will not seal.Do cables need to be secured?
Yes, the plate does not provide strain relief, so secure cables inside the board.Manufacturer documents
Links open on external websites. Checked 2026-10-04. If data differ, the latest manufacturer edition applies – or contact us.
HTKC-25 – plate with two-zone cones
The HTKC-25 membrane plate for a 216×84 mm cut-out takes up to 25 cables Ø5–26 mm; main ranges IP65, inner ranges IP55.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products