Products catalog

  • Membrane cable entry plate with cones | for 216×84 mm cut-out | 36 cables Ø4–32 mm | grey | IP65 | HT Hi Tech Polymers | HTKC-36

    Code: Sandariklis HTKC-36

    HTKC-36 is a membrane cable entry plate with cones for a 216×84 mm cut-out. Six cone sizes cover cables from Ø4 to Ø32 mm, up to 36 cables in total. Sealing rating is IP65.

  • Membrane cable entry plate with cones | for 216×84 mm cut-out | 36 cables Ø4–32 mm | grey | IP65 | HT Hi Tech Polymers | HTKC-36

    HTKC-36 is a TPE-SEBS elastomer plate for a 216×84 mm cut-out with cones in six sizes: from Ø4–8 mm up to Ø17–32 mm. Each cable gets the nearest cone, cut to its outer diameter. It is the most versatile layout where cables of very different thicknesses meet in one panel.

    Key point:
    A machine control cabinet typically has a supply cable, motor cables, valve and fan lines and thin sensor cables at the same time. HTKC-36 has a cone size for each of these groups, so all cables enter through one cut-out. Compared with HTC-35 it adds 4 cones Ø4–8 mm for the thinnest cables.
    Cables
    up to 36
    Cone sizes
    6
    Cable Ø
    4–32 mm
    Protection
    IP65

    How it works

    A 216×84 mm opening is cut in the enclosure, Ø10 mm fixing holes are drilled (spacing 193 × 62 mm) and the plate is screwed to the wall.

    After measuring the cable's outer diameter, a cone from the matching group is chosen and cut at a step slightly smaller than the cable. The cable is pushed through the cone.

    Cables of different thicknesses are sealed in one plate (IP65), unused cones stay closed.

    Why choose HTKC-36?
    No need to combine several different glands or plates – six cone sizes cover almost the entire cable range of a machine cabinet, from a thin sensor cable to a Ø32 mm supply cable.

    Technical specifications

    Product type Membrane cable entry plate with cones
    Code HTKC-36
    Manufacturer HT Hi Tech Polymers Oy (Finland)
    Entries and cable Ø 4 × Ø4–8 mm; 4 × Ø6–10 mm; 12 × Ø7–12 mm; 14 × Ø10–14 mm; 2 × Ø12–18 mm; 1 × Ø17–32 mm
    Max. number of cables 36
    Enclosure cut-out 216 × 84 mm (C-shape, FL21)
    Fixing holes Ø10 mm, spacing 193 × 62 mm
    Degree of protection IP65 (EN 60529)
    Operating temperature −40…+130 °C
    Material TPE-SEBS 50 ShA, halogen-free, oil-splash-resistant
    Colour grey (RAL 7035)
    Use indoor and outdoor

    Main functions

    • 1 cone Ø17–32 mm – for the cabinet supply cable
    • 2 cones Ø12–18 mm – for motor or sub-feeder cables
    • 14 cones Ø10–14 mm and 12 cones Ø7–12 mm – for actuator and control lines
    • 4 + 4 cones Ø4–8 and Ø6–10 mm – for sensor and communication cables
    • One-model solution – cables of different thicknesses through one cut-out

    Where is it used?

    • Pumping station and boiler room control cabinets
    • Heat substation and ventilation unit control panels
    • Machine tool and production equipment control cabinets
    • Conveyor and warehouse equipment panels
    • Water treatment and wastewater plant panels
    • Agricultural equipment (ventilation, feeding) control panels

    Use by need

    For machine builders (OEM).
    One plate fits different machine configurations – no need to change the entry solution for each order.
    For HVAC installers.
    Pump, valve and sensor cables enter through one cut-out, each into a cone of its own size.
    For facility managers.
    When a pump is replaced or a sensor added, free cones of various sizes allow a new cable without dismantling the entry.

    Practical application

    If a heat substation cabinet needs a Ø22 mm supply cable, two Ø15 mm pump cables, 10 valve and actuator cables Ø11–13 mm, 8 sensor cables Ø8–10 mm and 4 thin Ø5 mm bus cables, HTKC-36 takes them all and still leaves free cones.

    Pros

    • Six cone sizes – from Ø4 to Ø32 mm
    • Up to 36 cables through one cut-out
    • Operating temperature −40…+130 °C
    • IP65, for indoor and outdoor use
    • Halogen-free, oil-splash-resistant material

    Cons / limitations

    • The number of cones of each size is limited – for many identical thin cables HTKC-50 or HTKC-43 is better
    • Only one cable above Ø18 mm; for several thick cables use HTKC-28
    • Does not provide strain relief – cables must be secured inside the cabinet
    • Not a fire barrier

    Safety and installation notes

    • Make the cut-out with the power off; on vibrating equipment also make sure the plate screws are properly tightened.
    • Remove swarf from the wall and the inside of the cabinet.
    • Before cutting a cone, measure the cable's outer diameter – not the conductor cross-section.
    • Secure motor cables inside the cabinet so that vibration and pulling are not transferred to the cone.

    Quick selection guide

    Cut-out 216×84 mm
    6 cone sizes
    Ø4–32 mm, up to 36 cables
    IP65, −40…+130 °C
    Suitable when you need:
    • cables of very different thicknesses through one cut-out
    • one supply cable up to Ø32 mm
    • several thin sensor cables from Ø4 mm
    Check before use:
    • how many cables fall into each cone size
    • that there is only one cable above Ø18 mm
    • whether a 216×84 mm cut-out with Ø10 mm holes can be made in the enclosure
    Important reminder: HTKC-36 seals the entry (IP65), but it does not replace cable fixing against pulling and vibration and is not a fire-stop seal.

    FAQ

    What cable sizes does HTKC-36 accept?
    Cables from Ø4 to Ø32 mm outer diameter, in six cone groups.
    How does HTKC-36 differ from HTC-35?
    HTKC-36 adds 4 cones Ø4–8 mm for thin cables and has 14 cones Ø10–14 mm (HTC-35 has 16).
    Is it suitable for a Ø30 mm cable?
    Yes, the largest cone is for a Ø17–32 mm cable – there is one of them.
    What if a cable fits two cone sizes?
    Choose the cone whose range centre is closer to the cable diameter, so the other stays free.
    Is it suitable for vibrating equipment?
    The plate is elastic, but cables must be secured inside the cabinet so vibration is not transferred to the cone.
    Can it be used outdoors?
    Yes, the material is intended for indoor and outdoor use, protection IP65.

    Manufacturer documents

    Links open on external websites. Checked 2026-10-04. If data differ, the latest manufacturer edition applies – or contact us.

    HTKC-36 – plate for mixed cable sizes

    The HTKC-36 membrane plate with cones in six sizes for a 216×84 mm cut-out takes up to 36 cables from Ø4 to Ø32 mm, IP65, −40…+130 °C.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

  • Subscribtion to new arrivals