Products catalog

  • Membrane cable entry plate with cones | for 216×84 mm cut-out | 6× Ø13–28 + 18× Ø6–13 + 4× Ø3–11 mm | grey | IP65 | HT Hi Tech Polymers | HTKC-28

    Code: Sandariklis HTKC-28

    HTKC-28 is a membrane cable entry plate with cones for a 216×84 mm cut-out. It has 6 large cones Ø13–28 mm for power cables, 18 cones Ø6–13 mm and 4 cones Ø3–11 mm. Up to 28 cables in total, sealing rating IP65.

  • Membrane cable entry plate with cones | for 216×84 mm cut-out | 6× Ø13–28 + 18× Ø6–13 + 4× Ø3–11 mm | grey | IP65 | HT Hi Tech Polymers | HTKC-28

    HTKC-28 is a TPE-SEBS elastomer plate for a 216×84 mm cut-out with as many as six large cones Ø13–28 mm. Next to them are 18 cones Ø6–13 mm and 4 cones Ø3–11 mm. The cone tip is cut to the cable's outer diameter and each cable is sealed individually.

    Key point:
    Many 216×84 mm plates have only one or two entries for a thick cable. HTKC-28 is designed for boards that send out several power cables – to other boards, motors, heat pumps or charging points. Six cones up to Ø28 mm allow all of them to enter through one cut-out.
    Thick cables
    6 × Ø13–28 mm
    Medium
    18 × Ø6–13 mm
    Thin
    4 × Ø3–11 mm
    Protection
    IP65

    How it works

    A 216×84 mm opening is cut in the board wall, Ø10 mm holes are drilled (spacing 193 × 62 mm) and the plate is screwed on.

    Large cones are cut for thick cables, small ones for thin cables; each is cut at a step slightly smaller than the cable's outer diameter.

    Power and control cables are sealed in one plate (IP65), unused cones stay closed.

    Why choose HTKC-28?
    It fits up to six thick cables plus 22 medium and thin ones in one standard cut-out – without extra large glands with nuts.

    Technical specifications

    Product type Membrane cable entry plate with cones
    Code HTKC-28
    Manufacturer HT Hi Tech Polymers Oy (Finland)
    Entries and cable Ø 6 × Ø13–28 mm; 18 × Ø6–13 mm; 4 × Ø3–11 mm
    Max. number of cables 28
    Enclosure cut-out 216 × 84 mm (C-shape, FL21)
    Fixing holes Ø10 mm, spacing 193 × 62 mm
    Degree of protection IP65 (EN 60529)
    Operating temperature −40…+130 °C
    Material TPE-SEBS 50 ShA, halogen-free, oil-splash-resistant
    Colour grey (RAL 7035)
    Use indoor and outdoor

    Main functions

    • 6 cones Ø13–28 mm – for supply, sub-feeder and motor cables
    • 18 cones Ø6–13 mm – for circuit and control cables
    • 4 cones Ø3–11 mm – for thin signal or communication cables
    • Wide ranges – one cone suits cables of various thicknesses
    • Closed spare cones – stay sealed until used

    Where is it used?

    • Main and distribution boards in buildings feeding other boards
    • Industrial distribution cabinets with motor cables
    • Supply boards for EV charging points
    • Heat pump and boiler room power boards
    • Construction site distribution cabinets
    • Outdoor lighting and infrastructure boards

    Use by need

    For designers.
    When several power cables leave a board, a single cut-out solution simplifies enclosure selection and drawings.
    For electrical contractors.
    Six thick cables go in without separate large glands or extra holes in the wall.
    For plant energy engineers.
    When a new sub-feeder is added, a free large cone lets the cable in without dismantling the existing entry.

    Practical application

    If a building distribution board has an incoming cable Ø26 mm, four sub-feeder cables Ø18–22 mm to floor boards, 12 circuit cables Ø10 mm and 2 alarm cables Ø5 mm, HTKC-28 takes them all and one large cone is still left in reserve.

    Pros

    • Six cones for thick cables up to Ø28 mm
    • Wide ranges – Ø13–28 and Ø3–11 mm
    • Operating temperature −40…+130 °C
    • IP65, for indoor and outdoor use
    • Halogen-free, oil-splash-resistant material

    Cons / limitations

    • Not for cables thicker than Ø28 mm – choose HTX-23 (up to Ø48 mm) or HTC-3
    • Fewer entries for small cables than HTKC-50 or HTKC-43
    • Does not provide strain relief – thick cables must be secured inside the board
    • Not a fire barrier

    Safety and installation notes

    • All work in the board only with the power off and absence of voltage verified.
    • Remove swarf after cutting and drilling.
    • Thick cables are stiff – secure them inside the board so their weight and bending do not deform the cone.
    • Cut the cone at a step slightly smaller than the cable's outer diameter.

    Quick selection guide

    Cut-out 216×84 mm
    6 × Ø13–28 mm
    18 × Ø6–13 + 4 × Ø3–11 mm
    IP65, −40…+130 °C
    Suitable when you need:
    • several thick power cables through one cut-out
    • circuit and signal cables in the same plate
    • spare capacity for future sub-feeders
    Check before use:
    • the outer diameter of the thickest cable – no more than Ø28 mm
    • the number of thick cables – no more than six
    • whether thick cables can be secured inside the board
    Important reminder: HTKC-28 seals the entry (IP65), but does not carry the weight and pulling forces of thick cables and is not a fire-stop seal – fix the cables separately.

    FAQ

    How many thick cables can enter through HTKC-28?
    Up to six cables with an outer diameter of Ø13–28 mm.
    Is it suitable for a Ø30 mm cable?
    No, the largest cones are for up to Ø28 mm; for thicker cables choose HTX-23.
    What are the 4 cones Ø3–11 mm for?
    For thin signal, sensor or communication cables.
    Can it be fitted into the same cut-out as HTC-50?
    Yes, all plates of this series are for a 216×84 mm cut-out with the same fixing holes.
    Is HTKC-28 suitable for an outdoor cabinet?
    Yes, the material is intended for outdoor use, protection IP65, operating temperature −40…+130 °C.
    Do thick cables need to be secured?
    Yes, the plate does not provide strain relief, so they must be secured inside the board.

    Manufacturer documents

    Links open on external websites. Checked 2026-10-04. If data differ, the latest manufacturer edition applies – or contact us.

    HTKC-28 – plate for several power cables

    The HTKC-28 membrane plate with cones for a 216×84 mm cut-out takes 6 thick cables Ø13–28 mm, 18 medium and 4 thin cables, IP65.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

  • Subscribtion to new arrivals

    privacy policy

    Information