  • Panel network analyser and energy meter | 96×96 mm | 1P / 3P | 57.7–480 V AC | via CT …/5 A | class 0.5S | THD up to 63rd harmonic | RS485 Modbus RTU | VEXEN PNA9605DM

    Code: PNA9605DM

    Panel-mount 96×96 mm network analyser and energy meter for 1P / 3P networks up to 480 V AC. Connected via …/5 A current transformers, it measures energy in both directions to class 0.5S, displays THD and harmonics up to the 63rd and transmits data over RS485 Modbus RTU.

  • Panel network analyser and energy meter | 96×96 mm | 1P / 3P | 57.7–480 V AC | via CT …/5 A | class 0.5S | THD up to 63rd harmonic | RS485 Modbus RTU | VEXEN PNA9605DM

    VEXEN PNA9605DM is a digital network analyser and electricity meter for mounting in a panel door (96×96 mm front, 92×92 mm cut-out). It connects to three-phase or single-phase networks via …/5 A current transformers, so it covers any current up to 9999 A on the primary side. Voltages, currents, power, cos φ, frequency, energy in both directions and harmonic distortion are available on the display and over RS485 Modbus RTU.

    Key point:
    One device in the panel door replaces a voltmeter, ammeter, power meter and sub-metering meter. The electrician sees phase loading and THD on the spot without opening the door, while the same data goes to SCADA, BMS or a PLC. High currents do not call for an expensive direct-connected meter – a suitable current transformer is enough.
    Mounting
    Panel door, 96×96 mm
    Connection
    Via CT …/5 A, up to 9999 A
    Accuracy
    Active energy – class 0.5S
    Communication
    RS485 Modbus RTU + pulse
    ⇄ Bidirectional metering
    Measures energy imported from and exported to the grid in separate registers: kWh and kvarh import, export and total, also per phase. Check compatibility with a specific inverter's power or export limiting function against the inverter manufacturer's list of supported meters.

    Communication interfaces and integration

    RS485 Modbus RTU
    2400–38400 bps, address 1–247, parity none / even / odd, 1 or 2 stop bits. Values in IEEE 754 float registers: U, I, P, Q, S, cos φ, f, energy, THD, harmonics 2–63, demand, min / max. Up to 20 devices per bus.
    Pulse output
    Configurable energy type (active or reactive, import / export / total), pulse width 60, 100 or 200 ms, pulse weight 0.001–1000 kWh/imp. Suitable for a simple controller or an older metering system.
    Display and buttons
    Backlit LCD, 5 buttons: phase status, U/I, demand / cos φ / Hz, power and energy screens. Settings are password-protected.

    How it works

    The device fits into a 92×92 mm cut-out in the panel door (1–5 mm sheet metal) and is held in place with clamps. Voltage inputs are connected directly to the phases via 1 A fast-acting fuses, current inputs to the …/5 A secondary windings of the current transformers. No separate supply is needed – the device is powered from the measured voltage.

    In the menu you set the system (3P4W, 3P3W or 1P2W), the CT ratio (e.g. 250/5 A) and, if needed, CT direction correction – a reversed transformer can be corrected in software without rewiring. The device calculates instantaneous values, energy in both directions, demand over a selected interval and harmonics up to the 63rd.

    The result: all incomer or feeder parameters on the panel door and the same figures in SCADA or BMS via Modbus. Phase imbalance, excess reactive power or rising THD become visible before protection trips or a reactive energy charge arrives on the bill.

    Why choose the PNA9605DM?
    It combines sub-metering and power quality monitoring in a single 96×96 mm housing: class 0.5S energy in both directions, THD and harmonics up to the 63rd, maximum demand and min / max values – at the price of a panel meter.

    Technical specifications

    Product type Panel network analyser and electricity meter
    Manufacturer / model VEXEN PNA9605DM
    Network system 3P4W, 3P3W, 1P2W (selectable in menu)
    Rated voltage 3×230/400 V AC
    Measured voltage 57.7–276 V AC (L-N), 100–480 V AC (L-L)
    Current input Via CT …/5 A, 0.05–5(6) A
    CT primary current 1–9999 A (configurable)
    Frequency 50 / 60 Hz
    Accuracy – energy Active class 0.5S (IEC 62053-22), reactive class 2 (IEC 62053-23)
    Accuracy – parameters U and I 0.2 %, P 0.5 %, Q and S 1 %, cos φ 0.01, f 0.2 %
    Measured quantities U L-N and L-L, I per phase and N, P, Q, S, cos φ, phase angle, f, phase sequence
    Energy kWh and kvarh import / export / total, also per phase; VAh, Ah
    Power quality THD U and I, harmonics 2–63 (Modbus), min / max values
    Demand 0–60 min, sliding or fixed interval, maximum demand
    Communication RS485 Modbus RTU, 2400–38400 bps, address 1–247
    Pulse output 1, configurable, 60 / 100 / 200 ms
    Display Backlit LCD
    Power supply From the measured voltage (no separate supply needed)
    Dimensions 96×96×62 mm
    Panel cut-out 92×92 mm, sheet thickness 1–5 mm
    Terminals 0.5–2.5 mm²
    Degree of protection IP54 front, IP30 rear
    Operating temperature −25…+55 °C (storage −40…+70 °C)
    Humidity / altitude up to 95 % non-condensing, up to 3000 m
    Weight 340 g
    MID No – for sub-metering (internal metering, not for billing)

    Main functions

    • Energy in both directions – see separately how much is imported from and exported to the grid, active and reactive.
    • THD and harmonics up to the 63rd – spot distortion from variable frequency drives, UPS units or LED lighting before the neutral conductor overheats.
    • Maximum demand – shows the real peak to base your contracted capacity on when dealing with the grid operator.
    • CT direction correction – fix a reversed transformer in the menu without loosening terminals.
    • Neutral current – in a 3P4W system shows N loading and the effects of phase imbalance.
    • Min / max values – records voltage and current extremes without a separate data logger.
    • Modbus RTU with float registers – straightforward integration into SCADA, a PLC or Home Assistant via an RS485 converter.

    Wiring diagram – 3P4W via current transformers

    The diagram shows the most common connection: three-phase four-wire network, three CTs …/5 A, voltages via 1 A fuses, RS485 to the controller. Terminals are labelled by function – check the marking on the device.

    Wiring diagram – 3P4W via current transformers – VEXEN PNA9605DM | elsprendimai.eu
    ☝ Click the diagram to open an enlarged version.
    ⚠ The diagram is for guidance only and may contain inaccuracies. Before wiring, check it against the manufacturer's instructions and the marking on the device.
    The qualified electrician carrying out the installation is responsible for it. UAB „Elektrotechnikos sprendimai“ accepts no liability for the connection or any errors.

    Most common wiring errors

    ✗ CT phase does not match voltage phase L1 transformer connected to input I2 – power and cos φ are displayed incorrectly even though the currents look right.
    ✗ Reversed CT (P1/P2 or S1/S2) Phase power is shown as negative and energy is counted as export. Correct the wiring or use the CT direction setting in the menu.
    ✗ Wrong CT ratio in the menu All readings are off by the same factor as the ratio error. Set CT1 = primary current (e.g. 250), CT2 = 5.
    ✗ Open CT secondary circuit Hazardous voltage at the terminals and damage to the transformer. Short the secondary circuit before disconnecting the device.
    ✗ In a 3P3W system L2 connected to V2 The manufacturer specifies connecting L2 to the neutral terminal; otherwise voltages and power will be wrong.

    How does it differ from similar models?

    • VEXEN ESM3100DM – Modular DIN-rail meter for direct connection up to 100 A, MID certified. Choose it when the current is up to 100 A and certified metering is required; choose the PNA9605DM when the current is higher (via CT) and you need analysis and a display on the panel door.
    • TPM-01ES 3×250 A – Panel analyser supplied with 250 A CTs and event recording. The PNA9605DM works with any …/5 A transformers up to 9999 A, measures harmonics up to the 63rd and energy to class 0.5S.
    • Siemens SENTRON PAC2200 – Modular DIN-rail analyser for direct connection up to 65 A. The PNA9605DM mounts in the panel door and measures high currents via CTs.

    Where is it used?

    • Building or site main incoming panel – load and energy of all phases in one place
    • 0.4 kV feeders in substation distribution cabinets
    • Production line and compressor room panels – THD from variable frequency drives
    • Solar PV grid connection point – import and export metered separately
    • Generator and backup power panels
    • Server room and UPS distribution – neutral current and harmonics
    • Monitoring of reactive power compensation equipment
    • Sub-metering of tenants or departments via SCADA / BMS

    Use by role

    For panel builders.
    Standard 92×92 mm cut-out and power from the measured voltage – less wiring and one device instead of several meters.
    For energy managers.
    Maximum demand, cos φ and reactive energy provide the basis for compensation and for changing contracted capacity.
    For SCADA / BMS integrators.
    All values in IEEE 754 float registers, address and baud rate set in the menu, up to 20 devices on one RS485 bus.

    Practical example

    If the protection on a factory's 400 A incomer trips frequently while the meter shows only kWh, install a PNA9605DM with 400/5 A transformers: maximum demand will show on which phase and when the peak occurs, while THD and neutral current will show whether harmonics from variable frequency drives are causing the overheating.

    Pros

    • Energy in both directions, active class 0.5S
    • THD and harmonics up to the 63rd, min / max values
    • Works with any …/5 A transformers up to 9999 A
    • No separate power supply needed
    • RS485 Modbus RTU and configurable pulse output
    • IP54 front – suitable for panel doors
    • CT direction correction via menu

    Cons / limitations

    • No MID – for billing purposes choose a certified meter, e.g. VEXEN ESM3100DM
    • Current transformers are not included
    • No relay outputs, digital inputs or waveform capture – for event analysis choose a power quality analyser from the same category
    • Panel door mounting only – for DIN rail choose a modular analyser

    ⚡ Safety and installation notes

    • Install only with all voltages disconnected; hazardous voltage is present at the terminals during operation.
    • Protect the voltage inputs with external 1 A fast-acting fuses and provide a disconnecting device – the meter has no internal fuses.
    • Never open the current transformer secondary circuit while primary current is flowing – use shorting terminals.
    • Earth the CT secondary circuits according to the manufacturer's instructions.
    • RS485 – shielded twisted pair (~120 Ω), 120 Ω terminating resistors at both ends of the line, do not swap A / B.
    • After installation the terminals must not be accessible; work must be carried out by a qualified electrician.
    ☝ Elsprendimai.eu recommends: To complete the installation you will need current transformers …/5 A sized to the incomer current, fuses and fuse holders for the voltage circuits and, for connection to a computer or controller, an RS485 communication converter. For a one-off audit without installation – network analyser rental.

    Quick selection guide

    96×96 mm | panel door
    CT …/5 A | up to 9999 A
    class 0.5S | THD up to 63
    RS485 Modbus RTU
    Suitable when you need to:
    • measure currents above 100 A via transformers
    • see parameters on the panel door and send them to SCADA / BMS
    • monitor THD, cos φ and maximum demand
    Check before use:
    • that the CT secondary current is 5 A (not 1 A or mA)
    • that the panel has room for a 92×92 mm cut-out and 62 mm depth
    • that the network voltage does not exceed 276 V L-N / 480 V L-L
    Important reminder: The PNA9605DM does not replace a MID-certified billing meter or a protection relay – it measures and reports, but does not disconnect the circuit.

    FAQ

    Can the PNA9605DM be used for billing tenants?
    No, the device has no MID certification, so it is intended for sub-metering (internal metering) and analysis.
    Is it suitable for current transformers with 1 A secondary?
    The PNA9605DM is designed for …/5 A transformers; the manufacturer's manual mentions a separate version for 1 A secondary current.
    Does it need a separate 230 V supply?
    No, the device is powered from the measuring voltage inputs.
    Can it be mounted on a DIN rail?
    No, it is a panel-mount device for a 92×92 mm cut-out in the panel door.
    Does it measure energy exported to the grid?
    Yes, kWh and kvarh import, export and total are counted separately, also per phase.
    How many devices can be connected to one RS485 line?
    The manufacturer specifies up to 20 devices per line, each with a different address 1–247.

    Documents and sources

    VEXEN PNA9605DM – network analyser and meter for panel doors

    Panel-mount 96×96 mm network analyser for 1P / 3P networks via CT …/5 A: energy in both directions to class 0.5S, THD and harmonics up to the 63rd, maximum demand and RS485 Modbus RTU for integration into SCADA or BMS.

    Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.
  • Alternative products

    Electrical distribution | modular enclosure | box | distribution board | 36 modules (2x18) | 432x448x161mm | transparent door | waterproof | surface-mounted | plastic | IP65 | Legrand | PLEXO | 601986 | 3245066019864
    Code: 601986

    Hermetic electrical distribution enclosure designed for the safe installation of modular electrical devices in both indoor environments and more demanding outdoor or industrial conditions. This is a high-quality IP65 protection class electrical box adapted to protect automation, protection, and electrical distribution equipment from dust, moisture, water splashes, and mechanical impact. 

    Price 87.95 € VAT incl.
    ( 72.69 € VAT excl. )
    Membrane cable grommet (diaphragm) | for M9–M120 holes | for cable Ø2–100 mm | grey | IP65 | HT HSS
    Code: Sandariklis-diafragma, pilkas

    The grey HT HSS membrane cable grommet is pressed into a round hole in the enclosure and seals one cable – for Ø9–120 mm holes and Ø2–100 mm cables, IP65 (HSS-M100, HSS-M120 – IP54). Choose the size by the hole (the number after M) and the outer cable Ø; the range shown in the variant selector, e.g. 1.5–4.5 mm, is the wall thickness.

    Price 0.11 € - 7.79 € VAT incl.
    ( 0.09 - 6.44 € VAT excl. )
  • Subscribtion to new arrivals

    privacy policy

    Information