Cable entry plate for two heavy cables | 216×100 mm | 2× Ø14–64 mm | black | IP65 | HIK-2
Code: HIK-2HIK-2 cable entry plate – 216×100 mm, black, with two identical entries for cables Ø14–64 mm. Designed to bring two heavy power cables through a single opening in the board enclosure. Degree of protection IP65 (EN 60529).
-
Cable entry plate for two heavy cables | 216×100 mm | 2× Ø14–64 mm | black | IP65 | HIK-2
HIK-2 is a cable entry plate with two identical large entries, each for a cable Ø14–64 mm. It is intended where heavy power cables enter and leave a board. The plate is screwed to the enclosure with four screws through Ø10 mm holes.
Key point:
When two thick cables have to enter a board – for example, the mains supply and an outgoing cable to another building – two separate large glands take up a lot of space and need two large openings. HIK-2 fits both cables into one 216×100 mm plate. Both entries are identical, so it does not matter which side takes the incoming and which the outgoing cable.Plate
216×100 mmEntries
2 identicalCable Ø
14–64 mmProtection
IP65How it works
Installation: make an opening in the enclosure and fix the plate with four screws through the Ø10 mm holes.
Operation: cut each entry's cone at a step slightly smaller than the cable's outer Ø and push the cable through – the elastic material wraps around it.
Result: two heavy cables through one enclosure opening, the entry protected to IP65, an unused entry stays closed.
Why choose HIK-2?
HIK-2 lets two thick cables share one standard plate instead of two large glands. The wide Ø14–64 mm range covers most heavy power cables, so the same item suits different sites.Technical specifications
Product type Cable entry plate for two heavy cables Code HIK-2 Dimensions 216×100 mm Entries and cable Ø 2× Ø14–64 mm Max. number of cables 2 Fixing 4 holes Ø10 mm Degree of protection IP65 (EN 60529) Operating temperature −40…+100 °C Colour black Main functions
- Two large entries Ø14–64 mm – two heavy cables through one plate.
- Identical entries – no need to think which entry suits which cable.
- Wide range – from medium to very thick power cables.
- IP65 sealing – protection against dust and water jets.
- Spare capacity – if only one cable is needed for now, the second entry stays closed.
- Fixing with 4 screws – the plate is pressed evenly against the enclosure.
Where is it used?
- Building incoming boards with an incoming and outgoing cable
- Through-feed distribution boards (cable to another building)
- Boards with generator backup supply
- Supply boards for EV charging points
- AC connection boards of solar power plants
- Power boards of industrial equipment
Use by need
For the network designer.
Incoming and through-feed outgoing cable in one plate – a simpler layout at the bottom of the board.For the power cable installer.
One enclosure opening for two thick cables – less cutting and fewer sealing points.For the building manager.
If a second cable is needed later, the spare entry is already there – no need to cut the enclosure again.Practical use
If a building board has to take an incoming cable (sheath Ø about 30 mm) and an outgoing cable to a yard building (about Ø22 mm), cut one entry's cone at a step slightly smaller than 30 mm and the other at a step slightly smaller than 22 mm. Fix both cables inside the board with clamps.Pros
- Two heavy cables through one enclosure opening
- Wide Ø14–64 mm range for both entries
- IP65 protection
- Operating temperature −40…+100 °C
- The second entry can stay as a spare
Cons / limitations
- Only two entries – if thin cables are needed as well, choose HIK-1.
- The plate does not provide strain relief – cables must be fixed inside the board.
- For cables above Ø64 mm – HTX-1 (one cable Ø55–70 mm).
- For cables with pre-fitted ends (connectors) the splitting Morek MBA4N28B11 is more convenient.
Safety and installation notes
- Before working in the board, switch off the voltage and verify its absence.
- Remove swarf after cutting the opening – it can get into devices or onto busbars.
- Cut the cone step by step while measuring the cable's outer Ø – an oversized hole cannot be undone.
- A separate entry for each cable; never pass two cables through one cone.
- Fix heavy cables inside the board – their weight and pull must not rest on the plate.
Quick selection guide
216×100 mm2 entriesØ14–64 mmIP65Suitable when you need:- Two heavy power cables through one opening
- A spare entry for a second cable
- IP65 protection at the entry point
Check before use:- The outer diameters of both cables
- Whether a 216×100 mm plate fits on the enclosure
- How the cables will be fixed inside the board
Important reminder: HIK-2 seals the entry point, but it is not a fire barrier and does not replace cable strain relief.FAQ
What cable sizes does HIK-2 fit?
Cables with an outer diameter of Ø14–64 mm, one in each entry.Are both entries the same?
Yes, both are for a cable Ø14–64 mm.Can only one entry be used?
Yes, an uncut cone stays closed and sealed.Does the plate provide strain relief?
No – the cables must be fixed inside the board.What is the degree of protection?
IP65 according to EN 60529.What if several thin cables are needed too?
HIK-1 – one Ø15–64, one Ø15–35 and four Ø8–14 mm entries.Manufacturer documents
Links open on external websites. Checked 2026-10-04. If data differ, the latest manufacturer edition applies – or contact us.
HIK-2 cable entry plate 2× Ø14–64 mm
HIK-2 – black IP65 cable entry plate 216×100 mm for two heavy cables Ø14–64 mm, fixed with four screws.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Price 153.48 € VAT incl.( 126.84 € VAT excl. )Aluminium power cable | 4x35mm² | AXMK | Class 2 | 1m | blackCode: AXMK 4x35Price 6.05 € VAT incl.( 5.00 € VAT excl. )