Panel-mounted power quality analyser | 3-phase | via CT 5 A / 1 A | Un 220/380 V or 57.7/100 V | class 0.2S | harmonics and interharmonics up to 63rd | 2× Ethernet | 2× RS485 | Modbus TCP/RTU | IEC 61850 | ES-YDPQ200-A
Code: ES-YDPQ200-APrice 4728.44 € VAT incl.( 3907.80 € VAT excl. )Buy more, pay less2+ pcs. – 4161.02 € for pcs. -12%Permanently installed three-phase power quality analyser for panel doors (144×144 mm). Active energy class 0.2S, U and I ±0.1%, harmonics and interharmonics up to the 63rd, voltage dips, swells and interruptions, and 20 µs transients with waveform records. 16 GB memory (PQDIF, COMTRADE), 2× Ethernet, 2× RS485, Modbus TCP/RTU, IEC 61850 and GOOSE, 6 DI and 4 relay outputs.
-
Panel-mounted power quality analyser | 3-phase | via CT 5 A / 1 A | Un 220/380 V or 57.7/100 V | class 0.2S | harmonics and interharmonics up to 63rd | 2× Ethernet | 2× RS485 | Modbus TCP/RTU | IEC 61850 | ES-YDPQ200-A
ES-YDPQ200-A is a permanently installed three-phase power quality analyser for panel-door mounting (front 144×144 mm, cut-out 138×138 mm). Currents are connected via …/5 A or …/1 A current transformers, voltages directly or via voltage transformers. The device continuously measures network parameters, energy to class 0.2S, harmonics and interharmonics up to the 63rd, captures voltage events and short transients, and stores the data in 16 GB of memory.
Key point:
When “something is going on” in a panel – UPS units trip, capacitors burn out, variable frequency drives shut down – a simple meter gives no answer. This analyser records the time of the event to the millisecond, its duration, depth and waveform, so the cause can be proven rather than guessed. The same data goes to SCADA or EMS over Ethernet, and in substations via IEC 61850.Accuracy
class 0.2S, U and I ±0.1%Power quality
IEC 61000-4-30, harmonics up to 63rdEvents
Dips, swells, 20 µs transientsCommunication
2× Ethernet, 2× RS485, IEC 61850⇄ Bidirectional metering
Measures active energy imported from and exported to the grid, four-quadrant reactive energy, apparent energy, fundamental and harmonic energy, and multi-tariff energy. Check compatibility with a specific inverter's power or export control against the inverter manufacturer's list of supported meters.Communication interfaces and integration
2× Ethernet RJ45 – Modbus TCP, IEC 61850, GOOSE
10/100 Mbit/s, up to 10 Modbus TCP connections. IEC 61850 and GOOSE – for integration into substation automation and utility SCADA.2× RS485 – Modbus RTU
2-wire, 4800–115200 bps, parity none / odd / even, response time < 100 ms. Two separate lines – for example, local SCADA and a data logger.Time synchronisation
SNTP, PPS, IRIG-B and Modbus. With external synchronisation, event time accuracy is ±1 ms – records can be compared with those of other devices and protection relays.Inputs / outputs
6 DI (dry contact, internal 12 V), 4 NO relay outputs 5 A / 250 V AC or 5 A / 30 V DC, 2 energy pulse outputs and 1 second-pulse output, USB.Operating principle
The analyser fits into a 138×138 mm cut-out in the panel door. Auxiliary supply: 85–265 V AC or 100–330 V DC. Voltage inputs are connected via fuses either directly (220/380 V version) or via voltage transformers (57.7/100 V version); current inputs only via 5 A or 1 A current transformers. The fourth current channel, I4, is intended for the neutral or another circuit.
The signal is sampled at 1024 points per cycle. From this, the device calculates RMS values, power, energy, harmonics and interharmonics up to the 63rd, flicker, unbalance, and voltage and frequency deviations. A voltage dip, swell or interruption is recorded with its start time, duration and depth, and a short transient from 20 µs is captured with a waveform record.
Results are shown on a 5.7" colour display, stored in 16 GB of memory in PQDIF and COMTRADE formats and transmitted via Ethernet or RS485. Relay outputs can signal limit violations, while digital inputs can log switch positions together with power events.
Why choose ES-YDPQ200-A?
It replaces a permanently connected power quality recorder: it measures to class 0.2S, captures short disturbances, stores months of data and connects to the system via standard Modbus and IEC 61850 protocols. A single device at the incomer answers three questions – how much, what quality, and what happened.Technical specifications
Product type Permanently installed three-phase power quality analyser Manufacturer / code Elsp Group / ES-YDPQ200-A Network configuration 3-phase 4-wire or 3-phase 3-wire Channels 3 voltage, 4 current (I1–I3 + I4) Rated voltage Un 220/380 V or 57.7/100 V (version specified when ordering) Voltage measuring range 0.1–2 Un; overload 2 Un continuous, 4 Un for 1 s Rated current In 5 A or 1 A, via current transformers only Current measuring range 0.01–1.5 In; overload 1.5 In continuous, 10 In for 1 s Input burden < 0.5 VA per phase (voltage and current) Frequency 42.5–57.5 Hz, accuracy ±0.01 Hz Accuracy U / I ±0.1% Accuracy P / Q / S ±0.2% Power factor ±0.5% Phase angle ±0.2° Active / reactive energy class 0.2S / class 1.0 Power quality IEC 61000-4-30, flicker IEC 61000-4-15; harmonics and flicker – Class A (per manufacturer) Harmonics / interharmonics 2–63 / up to 63 Sampling 1024 points per cycle Transients from 20 µs, with waveform record Events and logs Dips, swells, interruptions; SOE and device logs of 1024 records each, 1 ms resolution Display 5.7" colour TFT, 640×480 Memory 16 GB; PQDIF, COMTRADE Communication 2× Ethernet RJ45 10/100 Mbit/s, 2× RS485, 1× USB Protocols Modbus TCP, Modbus RTU, IEC 61850, GOOSE Time synchronisation SNTP, PPS, IRIG-B, Modbus; ±1 ms with external synchronisation Digital inputs 6, dry contact, optically isolated, internal 12 V Relay outputs 4 NO, 5 A / 250 V AC, 5 A / 30 V DC (resistive), ≤ 20 ms Pulse outputs 2 energy + 1 second-pulse, max. 30 V DC / 50 mA Auxiliary supply 85–265 V AC 50/60 Hz or 100–330 V DC, ≤ 8 W Insulation 100 MΩ / 500 V; 2 kV 50 Hz 1 min; impulse 5 kV 1.2/50 µs Dimensions / cut-out 144×144×121 mm (incl. terminals) / 138×138 mm Operating conditions −25…+55 °C (storage −40…+70 °C), 5–95% RH non-condensing, up to 2000 m MID No – for sub-metering (not for billing) and analysis Key functions
- Voltage event recording – dips, swells and interruptions with time, duration and depth: evidence for a claim to the grid operator or equipment supplier.
- 20 µs transients and waveform records – see switching overvoltages that ordinary meters miss.
- Harmonics and interharmonics up to the 63rd – assess the impact of variable frequency drives, UPS units and inverters before the neutral conductor or capacitors overheat.
- Flicker and unbalance – objective figures when there are complaints about flickering lights or overheating motors.
- Class 0.2S energy in both directions – sub-metering, energy flow and loss analysis.
- 16 GB memory – data is retained even if communication is lost; the manufacturer states more than six months of records.
- Relay outputs and DI – limit-violation alarms and logging of switch positions together with events.
Wiring diagram – 3P4W via current transformers
The diagram shows a 3P4W incomer: three …/5 A CTs plus I4 on the neutral, voltages via fuses, separate auxiliary supply, Ethernet and RS485 to SCADA, and a relay output for alarm signalling. Terminals are labelled by function – check the numbering on the device.
☝ Click the diagram to open an enlarged version.⚠ The diagram is for guidance only and may contain inaccuracies. Before connecting, check against the manufacturer's instructions and the markings on the device.
The qualified electrician performing the installation is responsible for it. UAB „Elektrotechnikos sprendimai“ accepts no liability for the connection or possible errors.Most common wiring errors
✗ Wrong voltage version ordered 57.7/100 V version connected directly to a 230/400 V network or vice versa – incorrect readings or damaged inputs. ✗ CT phase does not match voltage phase Current and voltage phases swapped – power, cos φ and energy are wrong even though currents look correct. ✗ CT reversed Power is shown as negative and energy is counted as exported to the grid. ✗ Open CT secondary circuit Dangerous voltage and transformer damage – short-circuit the secondary before disconnecting the device. ✗ External voltage on DI Digital inputs are for dry contacts with internal 12 V – external voltage may damage them. How does it differ from similar models?
- VEXEN PNA9605DM – Panel-mounted 96×96 mm analyser and class 0.5S meter with THD up to the 63rd and RS485. Sufficient when you need to measure and transmit data; choose ES-YDPQ200-A when you need event recording, waveform records, Ethernet and IEC 61850.
- TPM-01ES 3×250 A – Panel-mounted analyser with 250 A CTs included and event capture via RS485. ES-YDPQ200-A measures to class 0.2S and adds an I4 channel, 16 GB memory and DI / DO.
- Analyser rental – For a one-off audit without installation; ES-YDPQ200-A is for permanent monitoring in the panel.
Where is it used?
- 10/0.4 kV transformer substations and substations – monitoring of incomers and busbar sections
- Factory incomers with variable frequency drives and welding equipment
- Data centres and UPS distribution
- Grid connection points of solar and other generating plants
- Monitoring of reactive power compensation equipment
- Panels in hospitals, airports and other critical facilities
- Energy management systems (EMS) and substation SCADA with IEC 61850
- Investigating power quality disputes with the grid operator
Use by role
For the energy engineer.
An event log with 1 ms resolution and waveform records make it possible to link trips to grid disturbances and substantiate claims.For the substation / SCADA integrator.
IEC 61850, GOOSE and Modbus TCP over two Ethernet ports, time synchronisation via PPS or IRIG-B.For the plant maintenance manager.
Harmonics, flicker and unbalance show which equipment is polluting the network before capacitors or motors fail.Practical example
If production lines with variable frequency drives stop several times a month for no obvious reason, install ES-YDPQ200-A at the incomer: within a few weeks the event log will show whether there was a voltage dip from the grid at that moment or a short overvoltage caused by switching of the compensation equipment, and the waveform record will provide clear evidence.Pros
- Active energy class 0.2S, U and I ±0.1%
- IEC 61000-4-30 methods, harmonics and interharmonics up to 63rd
- Events, 20 µs transients and waveform records
- 16 GB memory, PQDIF and COMTRADE
- 2× Ethernet, 2× RS485, IEC 61850, GOOSE
- 6 DI and 4 relay outputs
- Wide-range AC / DC auxiliary supply
Cons / limitations
- No MID approval – billing requires an approved meter
- Current and voltage transformers are not included
- The correct version must be selected: Un 220/380 V or 57.7/100 V, In 5 A or 1 A
- Advanced device – configuration and data analysis require experience; for simple metering VEXEN PNA9605DM is sufficient
- Panel-door mounting only, requires 121 mm depth
⚡ Safety and installation notes
- Install and service only with all voltages disconnected and the circuit earthed – as specified by the manufacturer.
- Protect voltage circuits and the auxiliary supply with fuses and provide a disconnecting device.
- Never open the CT secondary circuit while primary current is flowing – use a shorting / test terminal block.
- Do not exceed input limits: 2 Un continuous and 1.5 In continuous.
- RS485 – shielded twisted pair with 120 Ω termination resistors; DI – dry (volt-free) contacts only, do not apply external voltage.
- Work must be carried out by a qualified electrician.
☝ Elsprendimai.eu recommends: To complete the installation you will need …/5 A current transformers sized for the incomer current, fuses for the voltage and supply circuits, and for older systems with RS232 or USB – a communication converter. If you want to assess the problem first without installation – network analyser rental.Quick selection guide
144×144 mm | panel doorCT 5 A / 1 A | 3P4W / 3P3Wclass 0.2S | IEC 61000-4-30Ethernet | RS485 | IEC 61850Suitable when you need:- continuous power quality monitoring and event recording at an incomer or substation
- integration into SCADA / EMS via Modbus TCP or IEC 61850
- accurate (0.2S) bidirectional sub-metering
Check before ordering:- Un version: 220/380 V for direct connection or 57.7/100 V via voltage transformers
- In version: CT secondary current 5 A or 1 A
- availability of an auxiliary supply source and 121 mm of mounting depth in the panel
Important reminder: ES-YDPQ200-A does not replace an MID-approved billing meter or protection relays – it measures, records and signals, but does not trip the circuit.FAQ
Is the device suitable for a 3×230/400 V network?
Yes, the 220/380 V version measures 0.1–2 Un, so a 230/400 V network is within the measuring range.Can current be connected directly, without transformers?
No, the current inputs are intended for 5 A or 1 A current transformers only.How long is data retained without communication?
The manufacturer states that records are retained in the 16 GB memory for more than six months.Does it support IEC 61850?
Yes, IEC 61850 and GOOSE are supported via Ethernet, as well as Modbus TCP.Does it measure energy exported to the grid?
Yes, active energy is measured in both directions, reactive energy in four quadrants.Does it need a separate power supply?
Yes, 85–265 V AC or 100–330 V DC, up to 8 W.Data source
Technical data according to the manufacturer's manual and specification, checked on 2026-10-08. Terminal numbering and IP rating are not stated in the manufacturer's data – check them on the device.
ES-YDPQ200-A – class 0.2S power quality analyser for panel doors
Permanently installed three-phase PQ analyser via CT 5 A / 1 A: IEC 61000-4-30 methods, harmonics and interharmonics up to 63rd, events and 20 µs waveform records, 16 GB memory, Modbus TCP/RTU, IEC 61850 and GOOSE, 6 DI and 4 DO.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.ManufacturerThis product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Wind direction sensor | 0–360°, 16 directions of 22.5° | 12–24 V DC | RS485 Modbus RTU | for D105 pulse analyzer | smart-MAIC | T5WCode: T5WThe T5W wind vane sensor detects wind direction in 16 sectors of 22.5° (value 0–15, 0 = north). It connects to the RS485 input of the smart-MAIC D105 via Modbus RTU. 12–24 V DC supply is not included.
Price 174.05 € VAT incl.( 143.84 € VAT excl. )pH level sensor | pH 0…14 | 5 V DC | 80 cm cable | analog input | for D105 pulse analyzer | smart-MAIC | pH LevelCode: pH LevelSubmersible pH sensor for measuring water acidity in pools, aquariums and water treatment systems. It connects to the analog input of the smart-MAIC D105 and is powered from its 5 V terminal. Range pH 0…14, accuracy 0.2 pH.
Price 57.89 € VAT incl.( 47.84 € VAT excl. )TDS (dissolved solids) sensor | 0…1000 ppm | 0…2.3 V | 5 V DC | analog input | for D105 pulse analyzer | smart-MAIC | TDS LevelCode: TDS LevelTDS sensor for measuring dissolved salt concentration and assessing water hardness. It connects to the analog input of the smart-MAIC D105 and is powered from its 5 V terminal. It helps you see in time when filter cartridges need replacing.
Price 52.27 € VAT incl.( 43.20 € VAT excl. )CYKY-L 5G10 | 5×10 mm² | Copper power cable | 450/750 V | black | 1 m | LietkabelisCode: 91951013CYKY-L 5G10 (5×10 mm²) – 450/750 V copper power cable for three-phase 400 V circuits with neutral. Solid cores, PVC insulation and sheath, suitable indoors, outdoors and in the ground. AB Lietkabelis, price per 1 m.
Price 8.67 € VAT incl.( 7.17 € VAT excl. )Water flow sensor | up to 30 l/min | ~450 pulses/l | G1/2" (DN15) | 5 V DC | pulse input | for D105 pulse analyzer | smart-MAIC | DN15(G1/2")Code: DN15(G1/2")A turbine water flow sensor with G1/2" (DN15) connections for flows up to 30 l/min. It connects to a pulse input of the smart-MAIC D105 and gives about 450 pulses per litre. No separate supply is needed – the D105 provides 5 V.
Price 38.53 € VAT incl.( 31.84 € VAT excl. )