Code: ES-YDPQ200-APrice 4728.44 € VAT incl.( 3907.80 € VAT excl. )Buy more, pay less2+ pcs. – 4161.02 € for pcs. -12%Want another price? Suggest yours!Professional three-phase power quality analyzer designed for monitoring electrical network parameters, energy consumption, and power quality. Provides Class 0.2S active energy metering, analyzes harmonics and interharmonics up to the 63rd order, and records voltage dips, swells, interruptions, and transient events. Features a 5.7" TFT display, 16 GB internal memory, 2× RS485, 2× Ethernet, and USB interfaces, and supports Modbus RTU/TCP, IEC 61850, and GOOSE protocols. Suitable for industrial, energy, data center, solar power plant, SCADA, and energy management systems.
-
Three-Phase Power Quality Analyzer | Class 0.2S | 63 Harmonics | Ethernet Three-Phase Power Quality Analyzer | Class 0.2S | 63rd Harmonic Analysis | Ethernet / RS485
Professional three-phase power quality analyzer – a high-accuracy stationary measurement and monitoring device designed for real-time analysis of electrical network parameters, energy consumption and power quality. The device measures phase and line voltages, currents, active, reactive and apparent power, power factor, frequency, energy, phase imbalance, harmonics, interharmonics, voltage fluctuations, flicker and short-term network disturbances. Active energy metering accuracy complies with Class 0.2S, while voltage and current measurement accuracy reaches ±0.1%.
Class A power quality monitoring and in-depth network analysisThe analyzer is designed not only for basic electrical parameter measurement but also for professional power quality diagnostics. The device analyzes harmonics and interharmonics up to the 63rd order, performs sampling at 1024 samples per cycle, records voltage sags, swells and interruptions, can capture transient events as short as 20µs, record waveforms and register events with 1ms time resolution.
Class 0.2SActive energy accuracy63rd orderHarmonic and interharmonic analysis1024Samples per cycle5.7"Colour TFT displayMain measurement and analysis functions
Function Parameters Purpose / Capabilities Voltage measurement Phase and line voltage | ±0.1% Real-time monitoring of three-phase voltage, analysis of average values and network deviations. Current measurement 3 phases + additional I4 channel | ±0.1% Monitoring of phase currents, average current and the additional fourth current channel. Power measurement P, Q, S | ±0.2% Measurement of active, reactive and apparent power per phase and total. Energy metering Active Class 0.2S | Reactive Class 1.0 Forward and reverse active and reactive energy metering, suitable for energy audits and energy-flow monitoring. Harmonic analysis 2nd-63rd harmonics Analysis of voltage and current harmonic RMS values, phase angle, harmonic content, THD, even and odd harmonics. Interharmonic analysis Up to the 63rd order RMS and distortion analysis of interharmonics and subharmonics for complex industrial loads. Three-phase network imbalance Class A Monitoring of negative- and zero-sequence imbalance in three-phase voltage and current. Voltage quality events Sag / Swell / Interruption Records voltage sags, swells and interruptions, including start time, duration and disturbance depth. Transient event capture Down to 20µs Captures short-duration transient overvoltage events and automatically initiates waveform recording. Flicker analysis Class A Evaluation of short-term and long-term voltage flicker. Frequency monitoring 42.5 – 57.5Hz | ±0.01Hz Real-time measurement and recording of mains frequency and frequency deviation. Energy metering and energy-flow analysis
Bidirectional energy meteringThe analyzer records forward and reverse active energy, four-quadrant reactive energy and apparent energy. This makes it suitable not only for consumption measurement but also for systems where energy can flow in both directions, such as solar power plants, energy storage systems or local generation.
- Total active energy
- Forward and reverse active energy
- Four-quadrant reactive energy
- Forward and reverse apparent energy
- Fundamental harmonic energy
- Total harmonic energy
- 2nd-63rd harmonic energy metering
- Multi-tariff energy metering (TOU)
- Real-time and maximum power demand calculation
Data logging and event analysis
Function Capabilities Internal memory 16GB, data storage for approximately up to six months without connection to an external system. PQDIF Standardized power quality data storage format. COMTRADE Storage of waveform and disturbance records for analysis. SOE event recorder 1024 records, 1ms time resolution. Device log 1024 records, 1ms time resolution. Waveform recording Real-time, disturbance, scheduled and RMS-value recording. Max. / Min. values Automatic recording of maximum and minimum electrical parameter values and the time of occurrence. Communication interfaces and integration
2x RS485Modbus RTU2x RJ45Ethernet 10/100M1x USBUSB interfaceIEC 61850SCADA / substation integration- Modbus RTU via 2 RS485 interfaces
- Modbus TCP via Ethernet
- IEC 61850 communication protocol
- GOOSE support
- SNTP, PPS, IRIG-B and Modbus time synchronization
- Integration into SCADA, EMS, energy management and power quality monitoring systems
Inputs and outputs
Digital inputs (DI) 6 channels, dry contact, optical isolation Relay outputs (DO) 4 channels, NO contacts DO contact load 5A / 250V AC or 5A / 30V DC, resistive load Energy pulse outputs 2 channels Second pulse output 1 channel PPS synchronization input 1 channel Technical specification
Device type Stationary three-phase power quality analyzer Electrical network connection Three-phase 4-wire or three-phase 3-wire network Voltage channels 3 Current channels 4 Nominal measured voltage (Un) 57.7/100V or 230/380V Voltage measurement range 0.1Un – 2Un Nominal current (In) 1A or 5A Current measurement range 0.01In – 1.5In Frequency range 42.5 – 57.5Hz Voltage accuracy ±0.1% Current accuracy ±0.1% Active energy accuracy Class 0.2S Reactive energy accuracy Class 1.0 Active / reactive / apparent power accuracy ±0.2% Harmonic analysis Up to the 63rd order Interharmonic analysis Up to the 63rd order Sampling rate 1024 samples / cycle Shortest detectable transient event 20µs Display 5.7" TFT colour LCD, 640x480 Internal memory 16GB Data formats PQDIF, COMTRADE Communication interfaces 2x RS485 | 2x Ethernet RJ45 | 1x USB Communication protocols Modbus RTU | Modbus TCP | IEC 61850 | GOOSE Time synchronization Modbus | SNTP | PPS | IRIG-B Auxiliary AC power supply 85 – 265V AC, 50/60Hz Auxiliary DC power supply 100 – 330V DC Max. power consumption ≤8W Operating temperature -25°C ~ +55°C Storage temperature -40°C ~ +70°C Operating humidity 5% – 95% RH, non-condensing Operating altitude ≤2000m above sea level Standards and power quality analysis
IEC 61000-4-30 power quality measurement functionsThe device is designed for professional power quality monitoring and supports IEC 61000-4-30 measurement methods as well as IEC 61000-4-15 flicker analysis. Integrated functions include analysis of harmonics, interharmonics, voltage deviation, frequency deviation, three-phase imbalance, voltage fluctuations, flicker, rapid voltage changes, voltage sags, swells and interruptions.
Advantages / benefits
- Class 0.2S active energy metering – high accuracy for energy audits, metering and energy-flow analysis.
- ±0.1% voltage and current measurement accuracy for professional electrical system diagnostics.
- 63rd-order harmonic and interharmonic analysis helps identify distortion caused by inverters, UPS systems, variable frequency drives and other non-linear loads.
- 1024 samples per cycle provide high-speed waveform analysis.
- Transient capture down to 20µs allows extremely short network disturbances to be recorded.
- 16GB internal memory for long-term storage of statistical and event data.
- PQDIF and COMTRADE standard data formats simplify professional data analysis in external systems.
- 2x Ethernet, 2x RS485 and USB provide extensive integration capabilities.
- Modbus RTU/TCP, IEC 61850 and GOOSE allow the analyzer to be integrated into SCADA, EMS and power automation systems.
- Bidirectional energy metering is suitable for solar plants, energy storage systems and local generation facilities.
- 4 relay outputs and 6 digital inputs allow not only monitoring but also integration of warning and automation functions.
Disadvantages / limitations
- Professional device: due to its extensive functionality, proper parameter configuration and data interpretation require knowledge of electrical engineering and power quality analysis.
- Current measurement: nominal 1A or 5A current inputs are designed for operation through appropriately selected current transformers.
- The correct measurement input version must be selected: the technical specification provides nominal measured voltage options of 57.7/100V or 220/380V.
- Not a portable meter: the device is intended for stationary panel mounting in an electrical or automation cabinet.
- Not suitable when nominal input limits are exceeded: excessive measurement voltage or current may damage the device or reduce measurement accuracy.
What is it suitable for? (Applications)
- Power quality monitoring in industrial electrical networks
- Power quality control in data centres and UPS systems
- Energy-flow analysis in solar power plants and other generation systems
- Electrical energy audits in factories, production lines and industrial equipment
- Monitoring of transformer stations and electrical substations
- SCADA and EMS energy management systems
- Analysis of harmonics and electrical network distortion
- Evaluation of the impact of variable frequency drives, UPS systems, inverters and other non-linear loads on the electrical network
- Long-term power quality logging and fault diagnostics
What is it not suitable for?
- Basic household electricity metering where professional PQ analysis is not required
- Portable short-term measurements requiring a handheld mobile analyzer
- Direct measurement of high primary currents without suitable current transformers
- Systems whose measurement parameters exceed the specified input limits of the device
Practical example
A data centre operates UPS systems, server power circuits, variable frequency drives and other sensitive loads. A three-phase power quality analyzer is installed in the electrical panel and continuously measures voltage, current, power and energy flows. 63rd-order harmonic analysis helps identify distortion caused by non-linear loads, while 1024 samples per cycle and transient capture down to 20µs help detect short-duration disturbances. In the event of a voltage sag, swell or interruption, the device records the event time, duration and parameters and can save the waveform. Data is transferred via Ethernet to a SCADA or energy management system for further analysis.
Frequently asked questions (FAQ)
What is the active energy measurement accuracy?Active energy measurement accuracy is Class 0.2S, while reactive energy accuracy is Class 1.0.
How many harmonics can the device analyze?The device analyzes voltage and current harmonics up to the 63rd order and supports interharmonic analysis up to the 63rd order.
Is the analyzer suitable for both three-phase 3-wire and 4-wire networks?Yes. The device supports both three-phase three-wire and three-phase four-wire measurement configurations.
Which nominal measurement voltages are supported?The technical specification lists nominal voltages of 57.7/100V or 220/380V. The specific required input version must be selected according to the measurement system.
What is the nominal current input value?The current measurement input can be 1A or 5A. Current is normally measured through appropriately selected current transformers.
Can energy flow be monitored in both directions?Yes. The device records forward and reverse active energy as well as various reactive energy components, so it can be used in systems with local generation.
Does the device record voltage sags and swells?Yes. Voltage sags, swells and interruptions are recorded together with their occurrence time, duration and disturbance depth.
Can the device be connected to SCADA?Yes. The device has 2 RS485 interfaces, 2 Ethernet RJ45 ports and a USB interface. Modbus RTU, Modbus TCP, IEC 61850 and GOOSE protocols are supported.
Does the analyzer have internal memory?Yes. The device has 16GB of internal memory. Data can be stored in PQDIF and COMTRADE formats, and accumulated data can be retained for approximately up to six months without communication with an external system.
Important installation noteThe device must be installed by a qualified electrical specialist according to the specific electrical network configuration and technical documentation. Before installation or maintenance, the power supply must be completely disconnected and proper grounding must be ensured. The nominal measurement voltage, 1A or 5A current input, current and voltage transformer ratios and wiring configuration must be selected according to the specific electrical system. The specified measurement input limits must not be exceeded.
Three-phase power quality analyzer – a professional solution for continuous monitoring of electrical network parameters, Class 0.2S energy metering, harmonics, transient disturbances, energy flows and overall power quality in industrial, energy, data-centre and renewable-energy systems.
Illustrative image may have been created using AI. The appearance of the product may differ slightly from the image shown. Please refer to the technical specification.This product is marked with the CE label, which confirms that it complies with all applicable European Union directives and regulations. CE marking is not just a formality – it is an important indicator of quality and safety, ensuring that the product has been properly assessed, tested, and can be safely used throughout the EU market.
CE certification means that the product has been evaluated according to the main criteria:
Safety requirements – ensures that the product does not pose a risk to the user or the environment
Electromagnetic compatibility (EMC) – the device does not interfere with other equipment and is resistant to external disturbances
Environmental standards – complies with current ecological and material usage requirements
Operational reliability – the product is suitable for long-term use according to its intended purposeCE marking allows this product to:
be legally supplied and used in all European Union countries
ensure a high level of quality and safety
be used in residential, commercial, and industrial environmentsThe CE mark is a declaration of the manufacturer’s responsibility, confirming that the product complies with all applicable standards and has been assessed according to EU legislation.
What does this mean for you as a buyer?
Safe use in everyday activities
Reliable performance and reduced risk of failure
Compliance with EU standards and requirements
Suitability for professional solutions
Love it? Share your thoughts in a review!Write Review Alternative products
Price 9.32 € VAT incl.( 7.70 € VAT excl. )Price 174.05 € VAT incl.( 143.84 € VAT excl. )Water flow sensor | up to 30 l/min | ~450 pulses/l | G1/2" (DN15) | 5 V DC | pulse input | for D105 pulse analyzer | smart-MAIC | DN15(G1/2")Code: DN15(G1/2")Price 38.53 € VAT incl.( 31.84 € VAT excl. )pH level sensor | pH 0…14 | 5 V DC | 80 cm cable | analog input | for D105 pulse analyzer | smart-MAIC | pH LevelCode: pH LevelPrice 57.89 € VAT incl.( 47.84 € VAT excl. )TDS (dissolved solids) sensor | 0…1000 ppm | 0…2.3 V | 5 V DC | analog input | for D105 pulse analyzer | smart-MAIC | TDS LevelCode: TDS LevelPrice 52.27 € VAT incl.( 43.20 € VAT excl. )