Modular electrical network analyzers | mounted in electrical distribution boxes | panels
-
Electrical network analysers for panel mounting and on-site measurements: Smart-MAIC Wi-Fi modules, multi-channel analysers, Modbus modules and panel devices for SCADA / BMS systems, power quality and portable analysers.
-
Electrical network analysers – how to choose the right one
This group contains six types of devices – from simple Wi-Fi modules for homes to power quality analysers for industry. The choice depends on three questions: where the data must go (app and cloud or SCADA / BMS via Modbus), how many circuits you will monitor and whether you need power quality analysis (harmonics, events, waveforms).
Quick selection by situation
Situation What to choose House, apartment or small site – monitoring in an app and the cloud Smart-MAIC: single-phase D101-1, D101-2, three-phase D103-1, D103-2 Higher supply current, large cable or busbar D103-300A, D103-600A; Rogowski coils – D103-R10, D103-R20 Several circuits must be monitored at once EASEM 200 A, EASEM 300 A (19 channels), PC341 (16 CT); many lines – RF-CIM-96/32 Data must reach SCADA, BMS or a PLC (Modbus) Panel TPM-01ES 3×250 A (RS485), EI910, VEXEN PNA9605DM; modular ME631, ME231, Siemens PAC2200 Power quality analysis in the panel: harmonics, events, waveforms MQ21, ME831, ME537; class 0.2S and IEC 61850 – YDPQ200 One-off audit or troubleshooting Portable ME435, MI550, MQ41, MQ31 or analyser rental Generator or a separate circuit with a local display GV24-MK2 (5 A), GV24L-MK2 (50 mA) – voltage, frequency, current, operating hours Analyser types in this group
Type Devices Communication Suitable for Smart-MAIC Wi-Fi modules (DIN) D101-1, D101-2, D103-1, D103-2, D103-300A, D103-600A, D103-R10, D103-R20 Wi-Fi → cloud, MQTT Remote monitoring of buildings, homes, sites Multi-channel Wi-Fi EASEM 200 A, EASEM 300 A, PC341 Wi-Fi, Tuya / Smart Life Monitoring of individual circuits, bidirectional metering Modular Modbus devices and data collectors ME231, ME631, ME631-SD, ME531, Siemens PAC2200 RS485 Modbus RTU (ME231 – also Wi-Fi) SCADA, BMS, EMS, centralised monitoring Panel devices with display TPM-01E: TPM-01E 3×50 A, 3×100 A, 3×150 A, 3×200 A, 3×300 A, 3×400 A, 3×600 A, 3×800 A, 3×1000 A; TPM-01ES 3×250 A (RS485), TPM-01E 10 mA – 5,5 A; ME337: ME337ND2, ME337NR2, ME337NR3 (12–24 V DC), ME337CD2 (CT 1 A / 5 A); EI910, VEXEN PNA9605DM, HP292MX, RF-CIM-96/32 Mostly RS485 Modbus Panel door, local reading of values Power quality analysers MQ21, ME831, ME537, YDPQ200 Modbus TCP / RTU; YDPQ200 – also IEC 61850 Harmonics, events, waveforms, long-term monitoring Portable ME435, ME440, MI550, MQ41, MQ31, DW-6093, JS9600, PQA 25 A, PQA 500 A, PQA 2000 A Internal memory / SD Audits, diagnostics, commissioning Smart-MAIC modules – selection by current and sensor
Model Network Current sensor D101-1 1P 230 V Solid-core CT 100 A D101-2 1P 230 V Split-core (clip) CT 100 A, Ø13 mm D103-1 3P 3×230/400 V Solid-core CTs 100 A D103-2 3P 3×230/400 V Split-core (clip) CTs 100 A, Ø13 mm D103-300A 3P 3×230/400 V CT 300 A, Ø23 mm D103-600A 3P 3×230/400 V CT 600 A, Ø32 mm D103-R10 3P 3×230/400 V Rogowski coils 1000 A, inner Ø100 mm D103-R20 3P 3×230/400 V Rogowski coils 2000 A, inner Ø100 mm ℹ The D103 measures voltage, current, active power, energy in both directions and cos φ for each phase; data is updated every 5 s and logged every 1 min. Three-phase models require a neutral conductor, communication requires 2.4 GHz Wi-Fi. With a solid-core CT the conductor must be disconnected and passed through the ring; a split-core CT and a Rogowski coil are fitted without disconnecting the conductor.
⚠ What to check before buying
- Network: single-phase or three-phase; three-phase Smart-MAIC models require a neutral.
- Current and conductor size: whether the cable or busbar fits the CT window (Ø13 / 23 / 32 mm) or a Rogowski coil is needed.
- CT type: split-core is fitted without disconnection, solid-core requires disconnecting the conductor.
- Communication: Wi-Fi (2.4 GHz) or RS485 Modbus / Ethernet – must match your system.
- Whether current sensors are included – e.g. for the ME537 they are purchased separately.
- Whether you need power quality functions (harmonics, events, waveforms) or energy monitoring is enough.
- Mounting: DIN rail or panel door – check the cut-out size on the product page.
⚠ Most common mistakes
Mistake Consequence CT fitted backwards (current direction) Negative power, consumption shown as export CT and voltage input from different phases Wrong power and cos φ CT ratio not set in a panel analyser Readings wrong by a fixed factor ⚡ 1 A / 5 A CT secondary open under load Dangerous voltage, CT damage 5 GHz Wi-Fi or weak signal in a metal panel No connection – a 2.4 GHz network or an external antenna is needed RS485 A+/B− swapped or no 120 Ω at the end of the line No communication or intermittent data ⚡ Safe installation
- Analysers must be installed and connected only by a qualified electrician, with the power switched off and absence of voltage verified.
- Protect the voltage measuring circuits according to the manufacturer's instructions.
- The secondary circuit of 1 A / 5 A current transformers must never be opened under load. Rogowski coils and 333 mV output sensors do not have this hazard.
Frequently asked questions
How does an analyser differ from an electricity meter?
An analyser shows instantaneous values (voltage, current, power, cos φ) and logs their history – for diagnostics and control. A meter is designed for kWh metering; if tenants are billed from the readings, choose a MID electricity meter.
When should I choose a Rogowski coil?
When the current is high and the cable or busbar does not fit the CT window. The flexible coil is wrapped around the conductor without disconnecting it.
Can a solar power plant be monitored?
Analysers with bidirectional metering measure energy imported from and exported to the grid. Compatibility with inverter power / export control must be confirmed separately – bidirectional metering alone is not enough for that.
Want to measure first and buy later?
Rent the Smart-MAIC D103 analyser for 7, 14 days or longer – analyser rental.
Need to monitor water, temperature or CO₂ as well?
This is what the D105 pulse analyser and sensors are for – see the Accessories for smart network analysers group.
Need help choosing?
Tell us the network type, supply current, where the data must go and what you want to monitor – we will select the right analyser and current sensors. Current transformers and Rogowski coils are in a separate group.
Contact us +370 620 727331 - 16 of 43Price 205.73 € VAT incl.( 170.03 € VAT excl. )Modular digital power network analyser | 3P | 65 A | 276/480 V AC | 6 MW | DIN | Siemens | SENTRON | PAC2200CLP | 7KM2200-2EA40-1JB1Code: PAC2200CLPPrice 870.62 € VAT incl.( 719.52 € VAT excl. )Panel-mounted | digital three-phase 380V power network analyzer | 85-265VAC | 100-330VDC | 16GB | Ethernet | RS485 | RJ45 | ModbusCode: ES-YDPQ200-APrice 4728.44 € VAT incl.( 3907.80 € VAT excl. )Three-phase power analyzer | with data logging | harmonic analysis | accuracy class 0.2 | RS485 / RJ45 / Modbus TCPCode: ES-HP292MXPrice 857.41 € VAT incl.( 708.60 € VAT excl. )Smart 3-phase electrical energy analyzer | 19 channels | WiFi + mobile control | 300A (CT) | bidirectional kWhCode: ES-EASEM-D-TY300Price 348.33 € VAT incl.( 287.88 € VAT excl. )Smart 3-phase electrical energy analyzer | 19 channels | WiFi + mobile control | 200A (CT) | bidirectional kWhCode: ES-EASEM-D-TY200Price 348.33 € VAT incl.( 287.88 € VAT excl. )Portable three-phase electrical network analyzer | 3000A | 0–600V | digital display | non-invasive measurement with clamp | data loggingCode: ES-DW-6093Price 4053.19 € VAT incl.( 3349.74 € VAT excl. )Portable three-phase power network analyzer | power quality meter | harmonic analysis | high accuracyCode: ES-JS9600Price 6274.49 € VAT incl.( 5185.53 € VAT excl. )Smart 3-phase electrical network analyzer with WiFi | Tuya | 16 channels | up to 200A | for solar power systems and homesCode: ES-PC341-W-TYPrice 486.27 € VAT incl.( 401.88 € VAT excl. )Panel-mounted | Digital 380V power network analyzer three-phase | with current transformers (CT) 3x250A | RS485 Modbus RTUCode: ES-TPM-01ES-250DPrice 105.63 € VAT incl.( 87.30 € VAT excl. )Three-phase power quality analyzer with 2000A current clamps | 4 voltage + 4 current channels | 0–900V | 10" LCD | harmonics up to the 64th orderCode: ES-PQA2000-10Price 7852.90 € VAT incl.( 6490.00 € VAT excl. )Three-phase power quality analyzer with 500A current clamps | 4 voltage + 4 current channels | 0–900V | 10" LCD | harmonics up to the 64th orderCode: ES-PQA500-10Price 7852.90 € VAT incl.( 6490.00 € VAT excl. )Three-phase power quality analyzer with 25A current clamps | 4 voltage + 4 current channels | 0–900V | 10" LCD | harmonics up to the 64th orderCode: ES-PQA25-10Price 7852.90 € VAT incl.( 6490.00 € VAT excl. )Price 130.68 € VAT incl.( 108.00 € VAT excl. )Rogowski panel power analyzer | voltage and current measurement | 220 V AC | CT 1A/5A input | LCD display | 6 tariffs | MODBUS RS485 | ME337CD2Code: ESME337CD2Price 127.05 € VAT incl.( 105.00 € VAT excl. )Price 130.68 € VAT incl.( 108.00 € VAT excl. )